Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
A teljes adatlap letöltése PDF formátumban:
Termék leírása |
---|
G20 IO-Link module for digital inputs/outputs, 8 inputs and 8 outputs, 4 connections for roller motors |
General specifications | ||
---|---|---|
UL File Number | E223772 "For use in NFPA 79 Applications only" | |
MTBF | 90 a | |
Compatible roller motors | Interroll EC310, Interroll EC5000 24V AI (20W / 35W / 50W), Rulmeca BL3, Itoh Denki PM500XK, Itoh Denki PM500XC , PULSEROLLER Senergy-IDC | |
Indicators/operating means | ||
LED yellow/red | IO1 ... IO8: IO-Link status MOT1 ... MOT4: motor status |
|
Electrical specifications | ||
Auxiliary voltage | 18 ... 30 VDC PELV Max. 10 A Current limitation of the supply max. 30 A For UL: Z-type miniature circuit breaker in accordance with UL 1077, max. 20 A, required |
|
Operating voltage | 18 ... 30 V DC, PELV Max. 2.5 A (IO-Link) Current limitation of the supply max. 4 A |
|
No-load supply current | ≤ 25 mA | |
Operating current | max. 2.5 A | |
Interface | ||
Interface type | IO-Link | |
IO-Link revision | 1.1 | |
Device profile | Identification and Diagnosis - I&D | |
Process data | 8 byte inputs (STD/EXT) 6 byte outputs (STD) 18 byte outputs (EXT) |
|
Vendor ID | 1 (0x0001) | |
Device ID | Rev. A: 984066 (0x0F0402) (STD) - default 984065 (0x0F0401) (EXT) Rev. B: 984066 (0x0F0402) (STD) 984065 (0x0F0401) (EXT) 984070 (0x0F0406) (STD) - default 984069 (0x0F0405) (EXT) |
|
Data transfer rate | COM3 (230.4 kbits/s) | |
Min. cycle time | 1.2 ms (STD) 2 ms (EXT) |
|
SIO mode support | no | |
Compatible master port type | Class A |
|
Input | ||
Number/Type | 8 Inputs for 3-wire sensors (PNP), DC (IO1 ... IO8) | |
Supply | from IO-Link | |
Current loading capacity | 200 mA , overload and short-circuit protected | |
Input current | ≤ 5 mA (limited internally) | |
Switching point | Type 3 according to IEC 61131-2 | |
Output 1 | ||
Number/Type | 8 electronic outputs, PNP (IO1 … IO8), overload proof and short-circuit proof | |
Supply | from IO-Link | |
Current | 200 mA per output | |
Voltage | ≥ (Ue - 1.5 V) | |
Output 2 | ||
Number/Type | 4 outputs for DC roller motors (MOT1 ... MOT4) | |
Supply | via UPWR | |
Current loading capacity | 3.5 A (continuous), 5 A (< 2 s), max. 7.5 A (< 0.3 s) per motor Total current (continuous) max. 10 A per device |
|
Overload protection | Fuse 5 A, I2t = 53.7 A2s per motor | |
Signal level | Speed: US = 0.3 … 10 V in no-load operation Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ Direction of rotation: Digital output PNP UD low = high resistance UD high ≥ (UPWR -0.5 V) Current-carrying capacity 400 mA, overload proof and short-circuit proof |
|
Fault level | Motor fault: Digital input NPN 0 (no error) ≥ 125 µA 1 (error) ≤ 25 µA |
|
Output 3 | ||
Number/Type | 4 electronic outputs, PNP (DIR/OUT1 … DIR/OUT4), overload and short-circuit proof | |
Supply | via UPWR | |
Current | 400 mA per output | |
Voltage | ≥ (UPWR - 0.5 V) | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 EN 55011:2016 |
|
Standard conformity | ||
Degree of protection | EN 60529:2000 | |
Fieldbus standard | EN 61131-9:2013 | |
Input | EN 61131-2:2007 | |
Communication interface | IEC 61131-9 / IO-Link V1.1.2 | |
Emitted interference | EN 61000-6-4:2007 | |
Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006 | |
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
Relative humidity | 85 % non-condensing | |
Climatic conditions | For indoor use only | |
Altitude | ≤ 2000 m above MSL | |
Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks | |
Vibration resistance | 0.35 mm / 5 g 5 ... 500 Hz | |
Pollution degree | 2 | |
Mechanical specifications | ||
Degree of protection | IP54 according to EN 60529 | |
Connection | 24 V power (PWR): Piercing technology, black flat cable IO-Link: M12 round plug connector in accordance with EN 61076-2-101, LM type (4-pin, connector contacts, screw-locking, A-coded) Female connector: LF type or similar Inputs/outputs (IO), motors (MOT): M8 round plug connector in accordance with EN 61076-2-104 IO: LF type (4-pin, bushing contacts, screw-locking, A-coded) Female connector: LM type or similar MOT: NF type (5-pin, bushing contacts, snap-locking, B-coded) Female connector: NM type or similar |
|
Mass | 310 g | |
Dimensions | ||
Height | 27.5 mm | |
Width | 131.5 mm | |
Length | 54 mm | |
Mounting | 2 clips with ∅ 8 mm drill hole The module must be secured to a solid, continuous surface using the two lugs |
|
Cable length | 1 m (IO-Link) 0.5 m (IO1/2, IO5/6), 0.65 m (IO3/4, IO7/8) 0.5 m (MOT1, MOT3); 0.4 m (MOT2, MOT4) max. 10 m |
|
Note | The flat cable routing is designed for 100 actuation cycles |
System | Classcode |
---|---|
ECLASS 13.0 | 27242604 |
ECLASS 12.0 | 27242604 |
ECLASS 11.0 | 27242604 |
ECLASS 10.0.1 | 27242604 |
ECLASS 9.0 | 27242604 |
ECLASS 8.0 | 27242604 |
ECLASS 5.1 | 27242604 |
ETIM 9.0 | EC001597 |
ETIM 8.0 | EC001597 |
ETIM 7.0 | EC001597 |
ETIM 6.0 | EC001597 |
ETIM 5.0 | EC001597 |
UNSPSC 12.1 | 32151705 |
The rollerdrive motor control module ICA-8DIO4M1-G20-IO* is a field module with 8 combined sensor inputs or electronic outputs. The 4 outputs for controlling DC rollerdrive motors are optimized for:
Interroll EC310.
Interroll EC5000 24V AI (20W / 35W / 50W)
Rulmeca BL3
Itoh Denki PM500XK
Itoh Denki PM500XC
PULSEROLLER Senergy-IDC
The compact housing can be mounted directly into support profiles or cable ducts. The power supply U PWR is connectedby piercing technology via the black AS-Interface flat cable. The swiveling flat cable guide locks without tools by a snap-fit.
The combined inputs and outputs and the motor outputs are connected using cable outputs with M8 round connectors. The inputs and outputs have 4-pin female connectors with locking nut, the motor outputs have 5-pin snap-on female connectors. IO-Link is connected using a cable output with M12 4-pin round plug connector.The inputs and outputs are supplied via IO-Link. The motor outputs are supplied via U PWR.
The LEDs IO display the current switching state and as well a fault condition of the combined inputs/outputs. The LEDs M display the operating state of the motors (stop/run/fault).
The module is configured via IO-Link.
Brief Instructions | Nyelv | Fájltípus | Fájlméret |
---|---|---|---|
Instruction leaflet / Beipackzettel | ALL | 206 KB | |
Manuals | |||
Manual ICA-8DIO4M1-G20-IO Extended Version | ENG | 1788 KB | |
Manual ICA-8DIO4M1-G20-IO Standard Version | ENG | 1800 KB | |
Parameter Information | |||
IO-Link Parameter Datasheet ICA-8DIO4M1-G20-IO Extended Version / IO-Link Parameter Datasheet ICA-8DIO4M1-G20-IO Extended Version | ALL | 936 KB | |
IO-Link Parameter Datasheet ICA-8DIO4M1-G20-IO Standard Version / IO-Link Parameter Datasheet ICA-8DIO4M1-G20-IO Standard-Version | ALL | 946 KB |
CAD | Nyelv | Fájltípus | Fájlméret |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 3418 KB |
Certificates | Tanúsítvány sz. | Nyelv | Fájltípus | Fájlméret |
---|---|---|---|---|
Canada, USA UL | 2019-2-25, 2019-07-29 (A1/C0), 2020-10-21 (A2/C0); 2024-08-28 (A3/C0)-E223772 | ALL | 523 KB | |
IO-Link Manufacturer Declaration | CERT-5779A | ALL | 173 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-4980 | ALL | 163 KB |
Device Description Files/Drivers | Megjelenési információ | Fájltípus | Fájlméret |
---|---|---|---|
IODD for ICA-8DIO4M1-G20-IO (EXT) / IODD für ICA-8DIO4M1-G20-IO (EXT) | V1.01.000 / 2023-11-02 | ZIP | 172 KB |
IODD for ICA-8DIO4M1-G20-IO (EXT) Rev. B / IODD für ICA-8DIO4M1-G20-IO (EXT) Rev. B | V1.00.000 / 2023-11-02 | ZIP | 172 KB |
IODD for ICA-8DIO4M1-G20-IO (STD) / IODD für ICA-8DIO4M1-G20-IO (STD) | V1.01.000 / 2023-11-02 | ZIP | 171 KB |
IODD for ICA-8DIO4M1-G20-IO (STD) Rev. B / IODD für ICA-8DIO4M1-G20-IO (STD) Rev. B | V1.00.000 / 2023-11-02 | ZIP | 172 KB |
Software Tools | |||
IO-Link Offline Parameterization Tool / IO-Link Offline-Parametriertool | V1.00.006 / 2022-07-10 | ZIP | 96138 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|