General specifications |
Sensing range | 200 ... 4000 mm |
Adjustment range | 240 ... 4000 mm |
Dead band | 0 ... 200 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 85 kHz |
Response delay | ≤ 180 ms |
Indicators/operating means |
LED green | Operating display |
LED yellow | object in evaluation range |
LED red | error |
Electrical specifications |
Operating voltage | 10 ... 30 V DC , ripple 10 %SS |
No-load supply current | ≤ 50 mA |
Interface |
Interface type | Serial interface (programming adapter required) 9600 BPS, no parity, 8 data bits, 1 stop bit |
Input/Output |
Input/output type | 1 synchronization connection, bidirectional |
| 0 Level | 0 ... 1 V |
| 1 Level | 4 V ... UB |
| Input impedance | > 12 kΩ |
| Output current | < 12 mA |
| Pulse length | 0.5 ... 300 ms (level 1) |
| Pulse interval | ≥ 62.5 ms (level 0) |
Synchronization frequency | |
| Common mode operation | ≤ 16 Hz |
| Multiplex operation | ≤ 17 Hz / n , n = number of sensors , n ≤ 10 (factory setting: n = 5 ) |
Input |
Input type | 1 program input |
Level (evaluation limit 1) | 0 ... 1 V |
Level (evaluation limit 2) | 4 V ... UB |
Input impedance | > 12 kΩ |
Pulse length | 2 ... 10 s |
Output |
Output type | 1 analog output 4 ... 20 mA |
Resolution | Evaluation range [mm]/3200, however ≥ 0.4 mm |
Deviation of the characteristic curve | ≤ 0.2 % of full-scale value |
Repeat accuracy | ≤ 0.1 % of full-scale value |
Load impedance | ≤ 500 Ω at UB ≥ 14V ≤ 300 Ω at UB < 14V |
Temperature influence | ≤ 1.5 % of full-scale value |
Compliance with standards and directives |
Standard conformity | |
| Standards | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
Approvals and certificates |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Connection type | Connector plug M12 x 1 , 5-pin |
Degree of protection | IP67 |
Material | |
| Housing | PA-GF35 |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
Mass | 120 g |
Dimensions | |
| Height | 40 mm |
| Width | 40 mm |
| Length | 40 mm |
Factory settings |
Output | evaluation limit A1: 240 mm evaluation limit A2: 4000 mm output function: rising ramp |
Beam width | wide |
General information |
Supplementary information | Switch settings of the external programming adapter: "output load": pull-down "output logic": noninv |