Wsparcie Czujników Przemysłowych
Wsparcie Ochrony przed wybuchem

Multi-Input/Output F2D0-MIO-Ex12.FF.*

FieldConnex® Fieldbus
F2D0-MIO-Ex12.FF.*
  • For discrete inputs and outputs
  • Aluminum cast iron, IP66
  • Configurable cable entries for bus lines and field signal lines
  • International approvals
  • For FOUNDATION Fieldbus H1
  • Installation in Zone 1/Div. 1, intrinsically safe
  • Sensors in Zone 0/Div. 1
  • Monitors sensor condition
  • Removable terminals
  • Power, Com, Diagnostics, and Error LEDs
  • Test points for easy troubleshooting

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Pobierz pełną kartę katalogową w formie pliku PDF:


Dane techniczne  F2D0-MIO-Ex12.FF.*

Opis produktu
Multi-input/output for digital signals, stand-alone device with aluminum housing for field installation
General specifications
Design / MountingOutside installation
Installation in hazardous areaZone 1 / Div. 1
Electronic componentBinary multi-input/output R8D0-MIO-Ex12.FF* For technical data on installed electronic component see datasheet.
Fieldbus connection
Fieldbus typeFOUNDATION Fieldbus
Digital input
Number of inputs12
Galvanic isolation
Foundation Fieldbus/Field circuitsafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Low voltage
Directive 2014/35/EUEN 61010-1:2010
Standard conformity
Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient conditions
Ambient temperature-40 ... 70 °C (-40 ... 158 °F) hazardous area
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity≤ 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance10 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typeplug-in terminals , spring terminal and screw terminal
Core cross section
Busup to 2.5 mm2
Inputsup to 2.5 mm2
Cable diametersee table 2
Cable glandsensor inputs M16, fieldbus M20
Housing materialAluminum
Degree of protectionIP66
Mass1800 g
Data for application in connection with hazardous areas
EU-type examination certificateBVS 16 ATEX E 075 X
MarkingEx-Hexagon II 2 (1) G Ex ib [ia Ga] IIC T4 Gb , Ex-Hexagon II 3 (1) G Ex ic [ia Ga] IIC T4 Gc , Ex-Hexagon II 3 (1) G Ex ec [ia Ga] IIC T4 Gc , Ex-Hexagon I (M1) [Ex ia Ma] I , Ex-Hexagon II (1) D [Ex ia Da] IIIC , Ex-Hexagon II 2 (1) D Ex tb [ia Da] IIIC T130 °C Db
BusFISCO see EC-Type Examination Certificate
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014
International approvals
FM approvalpending
IECEx approvalIECEx BVS 16.0051X
Approved forEx ib [ia Ga] IIC T4 Gb , Ex ic [ia Ga] IIC T4 Gc , Ex ec [ia Ga] IIC T4 Gc , [Ex ia Ma] I , [Ex ia Da] IIIC , Ex tb [ia Da] IIIC T130 °C Db
Certificates and approvals
Marine approvalpending
General information
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027242610
ECLASS 12.027242610
ECLASS 11.027242610
ECLASS 10.0.127242610
ECLASS 9.027242610
ECLASS 8.027242610
ECLASS 5.127242610
ETIM 9.0EC001601
ETIM 8.0EC001601
ETIM 7.0EC001601
ETIM 6.0EC001601
ETIM 5.0EC001604
UNSPSC 12.139121008

Details: F2D0-MIO-Ex12.FF.*

Function

This fieldbus junction box holds a multi-input/output (MIO) for transferring signals from discrete inputs and valves to the control system. The MIO offers the same functionality as the components FD0‑VC‑Ex* and FD0‑BI‑*. The fieldbus junction box can be installed in Zone 1/Div. 1 with sensors and actuators located in Zone 0/Div. 1.

The housing, type F2, is made of sturdy cast aluminum for installation in rough environments. Fieldbus and field device entrances can be selected individually from a range of cable glands. Optionally, either screw terminals or spring terminals can be chosen.

Informative Literature: F2D0-MIO-Ex12.FF.*

Language Selection:
LiteratureJęzykTyp plikuRozmiar pliku
Application Report - Controlling and Monitoring liquid Helium at the Deutsches Elektronen-SynchrotronENGPDF361 KB
Application Report - Digital Communication in Steel-Plate ManufacturingENGPDF470 KB

Product Documentation: F2D0-MIO-Ex12.FF.*

Language Selection:
Safety and Security DocumentationJęzykTyp plikuRozmiar pliku
Instrukcja obsługiPOLPDF172 KB
Manuals
ManualENGPDF1595 KB

Design / Simulation: F2D0-MIO-Ex12.FF.*

Language Selection:
CADJęzykTyp plikuRozmiar pliku
CAD-files 2-D / CAD-Dateien 2-DALLZIP538 KB

Approvals: F2D0-MIO-Ex12.FF.*

Language Selection:
CertificatesNr. certyfikatuJęzykTyp plikuRozmiar pliku
Brasil TUV Rheinland BrazilTÜV 17.2298 XALLPDF1257 KB
Canada FMFM19CA0042XALLPDF1698 KB
China SITIIAS CCC Ex Certificate2021322314004067 (Singapore)ALLPDF1616 KB
Europe ATEXBVS 16 ATEX E 075 XALLPDF1629 KB
IECEx Certificate of ConformityIECEx BVS 16.0051XALLLINK---
USA FMFM19US0077XALLPDF1700 KB
Worldwide Fieldbus FoundationIT110300/02ALLPDF115 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-3160DALLPDF1064 KB

Software: F2D0-MIO-Ex12.FF.*

Language Selection:
Device Description Files/DriversInformacja o wersjiTyp plikuRozmiar pliku
DD/CFF files / DD/CFF-Dateien0104/010102ZIP209 KB

Ethernet-APL umożliwia ciągłą komunikację na wszystkich poziomach hierarchii. Dowiedz się więcej na temat tej pionierskiej technologii…

Usługa informacyjna RSS do aktualizacji PANOS

Otrzymuj najnowsze informacje o nowych aktualizacjach oprogramowania PANOS, czyli systemu operacyjnego do przełączników Ethernet-APL: Dzięki naszemu kanałowi RSS będziesz otrzymywać powiadomienia e-mail na swoją skrzynkę poczty przychodzącej po każdym wypuszczeniu nowej aktualizacji.

Od decyzji, poprzez planowanie, montaż i rozruch, aż do eksploatacji i utrzymania ruchu: Odkryj, jak najlepiej wykorzystać naszą infrastrukturę fieldbus…