Wsparcie Czujników Przemysłowych
Wsparcie Ochrony przed wybuchem

Stationary read device OPC120W-F200-R2-Ex

OPC120W-F200-R2-Ex
  • Explosion protection for use in Zone 1, Zone 2, Zone 21 and Zone 22
  • Reads 1-D and 2-D codes at high speeds of up to 6 m/s at 30 readings/s
  • High depth of focus
  • Code quality index output
  • Logo comparison
  • Presence detection

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Pobierz pełną kartę katalogową w formie pliku PDF:


Dane techniczne  OPC120W-F200-R2-Ex

Opis produktu
Stationary read device for hazardous area
General specifications
Light typeIntegrated LED lightning (white)
SymbologiesData Matrix, Code 39, Code 128, Int 2 of 5, EAN13, Pharmacode
Read distance60 ... 160 mm Nominal distance: 120 mm
Reading fieldMinimum read field: 28 mm x 45 mm
Read field at nominal distance: 44 mm x 70 mm
Maximum read field: 60 mm x 95 mm
Modul sizeMinimum module size: 0.3 mm
Evaluation frequencyup to 30 Hz
Target velocitytriggered max. 6 m/s
Data Matrix
Symbol sizerectangular up to 144 x 144 modules
rectangular up to 16 x 48 modules
Data formatASCII, C40, Text, X12, Edifact, Base 256 , all according to ISO 646
Orientationomnidirectional
Nominal ratings
Camera
TypeCMOS , Global shutter
Number of pixels752 x 480 pixels
Gray scale256
Image recordingreal-time , Program-controlled or triggered externally
Functional safety related parameters
MTTFd40.5 a
Mission Time (TM)8 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED green: Ready for operation
LED indicationfor good/poor reading
Electrical specifications
Operating voltage24 V DC ± 15% , PELV
No-load supply currentmax. 250 mA
Power consumption6 W
Interface
Interface typeserial , RS 232
Transfer ratemax. 115.2 kBit/s
Cable lengthmax. 30 m
Interface 1
Interface typeEthernet
ProtocolTCP/IP
Transfer rate100 MBit/s
Cable lengthmax. 30 m
Input
Input voltageto be applied externally 24 V ± 15% PELV
Number/TypeTrigger
Input currentapprox. 10 mA at 24 V DC
Switching thresholdlow: < 10 V, high: > 15 V
Cable lengthmax. 30 m
Output
Number/TypeGOOD, BAD, Matchcode
Switching typePNP
Switching voltageto be applied externally 24 V ± 15 % PELV
Switching current100 mA each output
Cable lengthmax. 30 m
Compliance with standards and directives
Standard conformity
Noise immunityEN 61326-1
Emitted interferenceEN 61000-6-4
Degree of protectionEN 60529
Laser classIEC 60825-1:2007
Approvals and certificates
IECEx approvalIECEx INE 14.0042X
ATEX approvalINERIS 14 ATEX 0035X
Device type: GUBW1.D.OS-OPC120W-F200-R2
MarkingEx-Hexagon II 2 GD
Ex db IIC T6 Gb
Ex tb IIIC T85°C Db
Ambient conditions
Ambient temperature0 ... 37 °C (32 ... 98.6 °F)
Mechanical specifications
Connection typeConnection terminals, max. conductor cross-section 2.5 mm2
Conductor cross section0.13 ... 2.5 mm2
Cable gland3 ... 8.5 mm
Enclosure coverthreaded round cover
Cover fixingflamepath thread
Cover sealnone, O-ring for IP66/67
Flamepath greasepetroleum jelly
Degree of protectionIP66 (IP66/IP67 with O-ring)
Material
Enclosurealuminum alloy
Glassthermo-resistant tempered glass
Finishepoxy coated RAL 7005 (grey)
Massapprox. 7 kg
Dimensions
Height279 mm
Width202 mm
Depth134 mm
GroundingM6 external grounding points

Classifications

SystemClasscode
ECLASS 13.027280103
ECLASS 12.027280103
ECLASS 11.027280103
ECLASS 10.0.127280103
ECLASS 9.027280103
ECLASS 8.027280103
ECLASS 5.127280103
ETIM 9.0EC002999
ETIM 8.0EC002999
ETIM 7.0EC002999
ETIM 6.0EC002999
ETIM 5.0EC002999
UNSPSC 12.143211701

Details: OPC120W-F200-R2-Ex

Function

With the OPC120, Pepperl+Fuchs provides the solution to code reading and detection tasks for many industries and applications.
Whether reading 1D and 2D codes at high speed, at varying intervals, reflective surfaces or a variety of detection tasks, with the OPC120 you always have the right Vision Sensor at your disposal.

Product Documentation: OPC120W-F200-R2-Ex

Language Selection:
ManualsJęzykTyp plikuRozmiar pliku
Manual optical print inspector OPC / OPD / OPEENGPDF3691 KB

Design / Simulation: OPC120W-F200-R2-Ex

Language Selection:
CADJęzykTyp plikuRozmiar pliku
CAD 3-D / CAD 3-DALLSTP834 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ88 KB

Approvals: OPC120W-F200-R2-Ex

Language Selection:
CertificatesNr. certyfikatuJęzykTyp plikuRozmiar pliku
Europe INERIS ATEXINERIS 14 ATEX 0035XALLPDF529 KB
Worldwide INERIS IECEx Certificate of ConformityIECEx INE 14.0042XALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4742ALLPDF97 KB

Software: OPC120W-F200-R2-Ex

Language Selection:
Software ToolsInformacja o wersjiTyp plikuRozmiar pliku
Software Vision Configurator / Software Vision ConfiguratorV6.7.0ZIP65423 KB
VSX-Interface libraries for communication with VSX sensors / Libraries zur Kommunikation mit VSX-SensorenV6.0.02.4945ZIP18196 KB

Produkty powiązane: OPC120W-F200-R2-Ex

Accessories
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable M12 plug straight D-coded to RJ45 Ethernet-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Identyfikacja optyczna

Od czytników kodów 2D i urządzeń ręcznych po skanery kodów kreskowych i rozwiązania specjalne — znajdź najlepsze rozwiązanie do identyfikacji optycznej dla danego zastosowania.