Atendimento ao Cliente da Divisão de Sensores Industriais
Rede de Atendimento - Divisão de Proteção Contra Explosão

AS-Interface repeater VAR-KE3-TERM

VAR-KE3-TERM
  • Minimum delay of signal
  • Line lengthening by 100 m (max. 2 repeater in series)
  • Galvanic isolation between AS-Interface segments A and B
  • No parameterization
  • Need no specific address on the AS-Interface bus
  • Housing with removable terminals
  • The integrated terminator permits up to 200 m network lengths on Segment A

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Faça o download das folhas de dados em PDF:


Folhas de dados: Dados técnicos do  VAR-KE3-TERM

Descrição do Produto
AS-Interface advanced repeater with terminator
General specifications
AS-Interface specificationV3.0
Required gateway specification≥ V2.0
UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source
Functional safety related parameters
MTTFd155 a
Indicators/operating means
SwitchTERM ON/OFF
switches the segment A terminator on/off
LED FAULT SEG ASegment A error display; red LED
red: communication error
LED FAULT SEG BSegment B error display; red LED
red: communication error
LED PWR SEG AAS interface voltage segment A; green LED
LED PWR SEG BAS-Interface voltage segment B; green LED
LED TERMSegment A bus terminator switched on
LED U>26VSegment A voltage > 26 V
LED U>18,5VSegment A voltage > 18.5 V
Electrical specifications
Insulation voltage≥ 500 V
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current60 mA (per strand element), 120 mA (total)
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 EN 61000-6-3:2001 IEC 62026-2:2008
Approvals and certificates
UL approvalAn isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device.
Ambient conditions
Ambient temperature0 ... 55 °C (32 ... 131 °F)
Storage temperature-25 ... 75 °C (-13 ... 167 °F)
Mechanical specifications
Degree of protectionIP20 according to EN 60529
Connectionremovable terminals, terminal connection ≤ 2.5 mm2
Material
HousingPA 66-FR
Dimensions
Height99 mm
Width22.5 mm
Depth114 mm
MountingDIN mounting rail

Classifications

SystemClasscode
ECLASS 13.027040301
ECLASS 12.027040301
ECLASS 11.027040301
ECLASS 10.0.127040301
ECLASS 9.027040301
ECLASS 8.027040301
ECLASS 5.127040301
ETIM 9.0EC001449
ETIM 8.0EC001449
ETIM 7.0EC001449
ETIM 6.0EC001449
ETIM 5.0EC002540
UNSPSC 12.139121535

Details: VAR-KE3-TERM

Design / Simulation: VAR-KE3-TERM

Selecione o Idioma:
CADIdiomaTipo de ArquivoTamanho do Arquivo
CAD 3-D / CAD 3-DALLSTP4525 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ1630 KB

Approvals: VAR-KE3-TERM

Selecione o Idioma:
CertificatesNúmero do CertificadoIdiomaTipo de ArquivoTamanho do Arquivo
US CA ULE223772ALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-2454CALLPDF109 KB

Produtos Relacionados: VAR-KE3-TERM

Accessory of
AS-Interface power extenderfa
Accessories
25-point wiring link for control cabinet modules with screw terminalsfa
Download gratuito: Documento técnico: protocolos de comunicação baseados em TCP (PDF)

Este documento técnico gratuito em PDF compara os diferentes protocolos de comunicação baseados em TCP (AMQP, OPC UA, MQTT, REST API) que alcançaram muito sucesso e hoje são considerados os ativadores da Internet Industrial das Coisas e da Indústria 4.0. Faça o download gratuito agora mesmo!

Linha de Produtos Interface AS

Conheça nossa linha completa de produtos Interface AS.