Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Faça o download das folhas de dados em PDF:
Folhas de dados: Dados técnicos do
VBA-2E2A-G2-ZEJ/XE2J
Descrição do Produto |
G2 flat module 2 inputs (PNP) and 2 electronic outputs |
General specifications |
Node type | A/B node |
AS-Interface specification | V3.0 |
Required gateway specification | ≥ V2.1 |
UL File Number | E223772 |
Indicators/operating means |
LED FAULT | error display; LED red red: communication error or address is 0 red flashing: overload of sensor power supply or outputs |
LED PWR | AS-Interface voltage; LED green |
LED IN | switching state (input); 2 LED yellow |
LED OUT | Switching state (output); 2 LED yellow |
Electrical specifications |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Rated operating current | ≤ 40 mA (without sensors) / max. 170 mA |
Protection class | III |
Surge protection | Ue: Over voltage category III, safe isolated power supplies (PELV) |
Input |
Number/Type | 2 inputs for 2- or 3-wire sensors (PNP), DC |
Supply | from AS-Interface |
Voltage | 21 ... 31 V |
Current loading capacity | ≤ 130 mA (TB ≤ 40 °C), ≤ 100 mA (TB ≤ 60 °C), overload and short-circuit protected |
Input current | ≤ 8 mA (limited internally) |
Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated) | ≤ 2 mA |
| 1 (attenuated) | ≥ 4 mA |
Output |
Number/Type | 2 electronic outputs, PNP overload and short-circuit proof |
Supply | from AS-Interface |
Current | limited by the current loading capacity of the module |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 |
Standard conformity |
Degree of protection | EN 60529:2000 |
Input | EN 61131-2:2007 |
Emitted interference | EN 61000-6-4:2001 |
AS-Interface | EN 62026-2:2013 |
Noise immunity | EN 61000-6-2:2001 |
Programming instructions |
Profile | S-B.A.E |
IO code | B |
ID code | A |
ID1 code | 7 |
ID2 code | E |
Data bits (function via AS-Interface) | InputOutput |
| D0 | - OUT1 |
| D1 | - OUT2 |
| D2 | IN3 - |
| D3 | IN4 - |
Parameter bits (programmable via AS-i) | function |
| P0 | not used |
| P1 | not used |
| P2 | not used |
| P3 | not used |
Ambient conditions |
Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Relative humidity | 85 % , noncondensing |
Climatic conditions | For indoor use only |
Altitude | ≤ 2000 m above MSL |
Pollution degree | 3 |
Mechanical specifications |
Degree of protection | IP67 |
Connection | cable piercing method: flat cable yellow inputs/outputs: M12 round connector |
Material | |
| Housing | PBT |
Mass | 100 g |
Tightening torque, cable gland | 0.4 Nm |
Mounting | Mounting plate |
Classifications
System | Classcode |
ECLASS 13.0 | 27242604 |
ECLASS 12.0 | 27242604 |
ECLASS 11.0 | 27242604 |
ECLASS 10.0.1 | 27242604 |
ECLASS 9.0 | 27242604 |
ECLASS 8.0 | 27242604 |
ECLASS 5.1 | 27242604 |
ETIM 9.0 | EC001599 |
ETIM 8.0 | EC001599 |
ETIM 7.0 | EC001599 |
ETIM 6.0 | EC001599 |
ETIM 5.0 | EC001599 |
UNSPSC 12.1 | 39121535 |
Details:
VBA-2E2A-G2-ZEJ/XE2J
Product Documentation:
VBA-2E2A-G2-ZEJ/XE2J
Approvals:
VBA-2E2A-G2-ZEJ/XE2J
Produtos Relacionados:
VBA-2E2A-G2-ZEJ/XE2J
Matching System Components |
|
|
|
AS-Interface module mounting base for connection to flat cable (AS-Interface and external auxiliary power)fa |
|
Accessories |
|
|
|
AS-Interface Handheld with accessoryfa |
|
|
|
|
Adapter cable module/hand-held programming devicefa |
|