Atendimento ao Cliente da Divisão de Sensores Industriais
Rede de Atendimento - Divisão de Proteção Contra Explosão

AS-Interface sensor/actuator module VBA-4E3A-KE-ZE/R

VBA-4E3A-KE-ZE/R
  • A/B node with extended addressing possibility for up to 62 nodes
  • Housing with removable terminals
  • Communication monitoring
  • Inputs for 2- and 3-wire sensors
  • Isolated relay output
  • Addressing jack
  • Supply of inputs external or from the module, as required
  • Function display for bus, internal input supply, inputs and outputs

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Faça o download das folhas de dados em PDF:


Folhas de dados: Dados técnicos do  VBA-4E3A-KE-ZE/R

Descrição do Produto
KE switch cabinet module, 4 inputs (PNP) and 3 relay outputs
General specifications
Node typeA/B node
AS-Interface specificationV2.1
Required gateway specification≥ V2.1
ProfileS-7.A.0
IO code7
ID codeA
ID1 code7
ID2 code0
UL File NumberE106378
Indicators/operating means
LED FAULTFault display; Red LED
red: Communication fault or address is 0
red, flashing: Overload, internal input supply
LED INTInternal input supply active; LED green
LED PWRAS-Interface voltage; LED green
LED INswitching state (input); 4 LED yellow
LED OUTSwitching state (output); 3 LED yellow
Electrical specifications
Auxiliary voltage (input)12 ... 30 V DC PELV
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current≤ 35 mA (without sensors) / max. 235 mA
Surge protectionO1 ... O3: Over voltage category II
UEXT, Ue: Over voltage category III, safe isolated power supplies (PELV)
Input
Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT)
Voltage21 ... 31 V DC (INT)
Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT)
Input current≤ 8 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 (Type 2)
0 (unattenuated)≤ 2 mA
1 (attenuated)≥ 4 mA
Signal delay< 2 ms (input/AS-Interface)
Signal frequency≤ 250 Hz
Output
Number/Type3 relay outputs, normally open
Supplynone
Nominal load
Per contactmax. 2 A / 30 V DC; 2 A / 250 V AC
Per module6 A
Minimum load
Per contact10 mA / 5 V DC
Short-circuit-proofContact: 500 A / 40 ms
Switching off power500 VA
Switching delay< 10 ms (AS-Interface/contact)
Usage categoryDC-13 and AC-14
Switching frequency< 20 Hz (without load)
< 0.1 Hz (nominal load)
Switching
Mechanical30 x 106
Electrical1 x 106 switching cycles (40 V DC, 2 A, ohmic)
0.5 x 106 switching cycles (253 V AC, 2 A, cos φ = 1)
0.45 x 106 switching cycles (253 V AC, 2 A, cos φ = 0.7)
Galvanic isolation
Input/OutputIN1 ... IN4 to O1 ... O3: safe isolation acc. to EN 60947-1,
rated insulation voltage 278 V AC
Input/AS-Interfacenone
Output/OutputO1 to O2, O3: safe isolation according to EN 60947-1,
rated insulation voltage 278 V AC
O2 to O3: basic insulation according to EN 60947-1,
rated insulation voltage 278 V AC
Output/AS-Interfacesafe isolation acc. to EN 60947-1,
rated insulation voltage 278 V AC
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007
Low voltage
Directive 73/23/EECEN 60947-1:2007
Standard conformity
Galvanic isolationEN 60947-1
Electromagnetic compatibilityNAMUR NE 21: 1998-08
Degree of protectionEN 60529:2000
Pollution degreeEN 60947-5-1
InputEN 61131-2:2004
Usage categoryEN 60947-5-1
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityEN 61000-6-2:2005
Ambient conditions
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity85 % , noncondensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Pollution degree2
Mechanical specifications
Degree of protectionIP20
Connectionremovable terminals
rated connection capacity:
rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2
for multiple-wire connection with two wires of equal cross-section:
flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Material
HousingPA 66-FR
Mass170 g
Dimensions
Height99 mm
Width22.5 mm
Length102 mm
MountingDIN mounting rail
Tightening torque of clamping screws0.5 Nm ... 0.6 Nm

Classifications

SystemClasscode
ECLASS 13.027242604
ECLASS 12.027242604
ECLASS 11.027242604
ECLASS 10.0.127242604
ECLASS 9.027242604
ECLASS 8.027242604
ECLASS 5.127242604
ETIM 9.0EC001599
ETIM 8.0EC001599
ETIM 7.0EC001599
ETIM 6.0EC001599
ETIM 5.0EC001599
UNSPSC 12.139121535

Details: VBA-4E3A-KE-ZE/R

Product Documentation: VBA-4E3A-KE-ZE/R

Selecione o Idioma:
Brief InstructionsIdiomaTipo de ArquivoTamanho do Arquivo
Instruction leaflet / BeipackzettelALLPDF605 KB

Design / Simulation: VBA-4E3A-KE-ZE/R

Selecione o Idioma:
CADIdiomaTipo de ArquivoTamanho do Arquivo
CAD 3-D / CAD 3-DALLSTP112 KB
CAD Portal / CAD PortalALLLINK---

Approvals: VBA-4E3A-KE-ZE/R

Selecione o Idioma:
CertificatesNúmero do CertificadoIdiomaTipo de ArquivoTamanho do Arquivo
Canada UL cULE106378 cUL (QUZW7)ALLLINK---
USA ULE106378 UL (QUZW)ALLLINK---
Worldwide AS-International Association AS-Interface43201ALLPDF608 KB

Produtos Relacionados: VBA-4E3A-KE-ZE/R

Accessories

AS-Interface Handheld with accessoryfa

Adapter cable module/hand-held programming devicefa
25-point wiring link for control cabinet modules with screw terminalsfa
Download gratuito: Documento técnico: protocolos de comunicação baseados em TCP (PDF)

Este documento técnico gratuito em PDF compara os diferentes protocolos de comunicação baseados em TCP (AMQP, OPC UA, MQTT, REST API) que alcançaram muito sucesso e hoje são considerados os ativadores da Internet Industrial das Coisas e da Indústria 4.0. Faça o download gratuito agora mesmo!

Módulo do gabinete do interruptor KE5 da Interface AS – Manuseio simples e capacidade de gerenciamento aprimorada

O design exclusivo do invólucro do novo módulo de gabinete do interruptor KE5 permite uma visibilidade distinta e simplifica a montagem, o cabeamento e a manutenção dentro dos gabinetes do interruptor e caixas de junção.

Linha de Produtos Interface AS

Conheça nossa linha completa de produtos Interface AS.