Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Faça o download das folhas de dados em PDF:
General specifications | ||
---|---|---|
Design / Mounting | Outside installation | |
Fieldbus connection | ||
PROFIBUS PA | ||
Connection | Connection +, - | |
Rated voltage | 9 ... 32 V | |
Rated current | max. 23 mA | |
Baud rate | 31.25 kBit/s | |
Protocol | PROFIBUS DP V1 | |
Terminal "S" | only for the connection of the cable screen (BUS) and/or the potential compensation | |
Terminal "PA" | only for the connection of the cable screen (sensor interface) and/or grounding | |
Grounding plate | only for the connection of the potential compensation | |
Field circuit | ||
Inputs | ||
Connection | 4, for binary sensors: terminals 1+, 2-, 5+, 6-, 9+, 10-, 13+, 14- 8, for binary sensors: terminals 3, 4, 7, 8, 11, 12, 15, 16 |
|
Sensor supply voltage | 4, for binary sensors: 5.5 V 8, for binary sensors: 5 V |
|
Sensor supply current | 4, for binary sensors: 4.5 mA 8, for binary sensors: ≤ 5 mA |
|
Time delay before availability | for 4 binary sensors, 1 s for 8 binary sensors, < 3 ms |
|
Max. cycle time | for binary 4 sensors, 4 x 1 s = 4 s for 8 binary sensors, 8 x 12.5 ms = 100 ms |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Galvanic isolation | EN 60079-11 | |
Electromagnetic compatibility | NE 21:2006 | |
Degree of protection | IEC/EN 60529 | |
Fieldbus standard | EN 50170/2 | |
Ambient conditions | ||
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications | ||
Core cross section | Bus cable:∅ 5 mm ... 10 mm cable sensors: ∅ 4 mm ... 8 mm |
|
Housing | 187 mm x 129 mm x 46 mm | |
Degree of protection | IP65 | |
Installation position | Cable glands downwards | |
Mass | approx. 290 g | |
Mounting | wall mounting | |
Data for application in connection with hazardous areas | ||
EU-type examination certificate | PTB 98 ATEX 2210 | |
Marking | II 2G (1) Ex ia [ia Ga] IIC T4 Gb , II (1D) [Ex ia Da] IIIC , II 3G Ex ic IIC T4 Gc , II (3D) [Ex ic Dc] IIIC |
|
PROFIBUS PA | ||
Voltage | 24 V | |
Current | 380 mA | |
Power | 5.32 W | |
Rated voltage | 9 ... 32 V | |
Rated current | 23 mA | |
FDE (Fault Disconnect Equipment) | 6.7 mA | |
Terminal "S" | only for the connection of the cable screen (BUS) and/or the potential compensation | |
Terminal "PA" | only for the connection of the cable screen (sensor interface) and/or grounding | |
Grounding plate | only for the connection of the potential compensation | |
Field-side | ||
Voltage | 9 V | |
Current | 44 mA | |
Power | 99 mW | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 | |
International approvals | ||
IECEx approval | IECEx TUN 04.0002 | |
Approved for | Ex ia [ia Ga] IIC T4 Gb , [Ex ia Da] IIIC , Ex ic IIC T4 Gc , [Ex ic Dc] IIIC |
|
General information | ||
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27242610 |
ECLASS 12.0 | 27242610 |
ECLASS 11.0 | 27242610 |
ECLASS 10.0.1 | 27242610 |
ECLASS 9.0 | 27242610 |
ECLASS 8.0 | 27242610 |
ECLASS 5.1 | 27242610 |
ETIM 9.0 | EC001601 |
ETIM 8.0 | EC001601 |
ETIM 7.0 | EC001601 |
ETIM 6.0 | EC001601 |
ETIM 5.0 | EC001604 |
UNSPSC 12.1 | 39121008 |
Literature | Idioma | Tipo de Arquivo | Tamanho do Arquivo |
---|---|---|---|
Application Report - Controlling and Monitoring liquid Helium at the Deutsches Elektronen-Synchrotron | ENG | 361 KB | |
Application Report - Digital Communication in Steel-Plate Manufacturing | ENG | 470 KB |
System Descriptions | Idioma | Tipo de Arquivo | Tamanho do Arquivo |
---|---|---|---|
Planning and integration: Compatibility list of sensors and pilot valves | ENG | 50 KB | |
Safety and Security Documentation | |||
Instruction Manual FD0-BI-Ex12.PA / Betriebsanleitung FD0-BI-Ex12.PA | ALL | 341 KB |
Certificates | Número do Certificado | Idioma | Tipo de Arquivo | Tamanho do Arquivo |
---|---|---|---|---|
Europe PTB II 2 G (1) II (1D) II (3D) II 3 G ATEX | PTB 98 ATEX 2210 | ALL | 1378 KB | |
TUV Nord IECEx Certificate of Conformity | IECEx TUN 04.0002 | ALL | LINK | --- |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F) | DOC-0812B | ALL | 88 KB |
Device Description Files/Drivers | Informações | Tipo de Arquivo | Tamanho do Arquivo |
---|---|---|---|
GSD / GSD | Rev 1.3 | ZIP | 4 KB |
Serviço de informações RSS sobre atualizações do PANOS