Folhas de dados: Dados técnicos do
GD18-S/GV18-S/73/120
Descrição do Produto |
Thru-beam sensor, M18 threaded housing design, plastic housing, side optical face, 12 m detection range, red light, light/dark on, DC version, 2 PNP outputs, M12 plug |
System components |
Emitter | GD18-S/159 |
Receiver | GV18-S/73/120 |
General specifications |
Effective detection range | 0 ... 12 m |
Threshold detection range | 17.5 m |
Light source | LED |
Light type | modulated visible red light , 640 nm |
Diameter of the light spot | approx. 650 mm at 17.5 m |
Opening angle | approx. 2 ° |
Optical face | lateral |
Ambient light limit | 30000 Lux |
Functional safety related parameters |
MTTFd | 630 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green, statically lit Power on |
Function indicator | Receiver: LED yellow, lights up when light beam is free, flashes when falling short of the operating reserve ; OFF when light beam is interrupted |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
No-load supply current | < 20 mA |
Output |
Switching type | light/dark on |
Signal output | 2 PNP, complementary, short-circuit protected, open collectors |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA |
Voltage drop | ≤ 1.5 V DC |
Switching frequency | 500 Hz |
Response time | ≤ 1 ms |
Conformity |
Product standard | EN 60947-5-2 |
Approvals and certificates |
Protection class | II, Rated insulation voltage ≤ 50 V AC with pollution degree 1-2 according to IEC 60664-1 |
UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications |
Degree of protection | IP67 |
Connection | 4-pin, M12 x 1 connector |
Material | |
| Housing | PC |
| Optical face | PMMA |
| Connector | plastic |
Mass | approx. 10 g per device |
Dimensions | |
| Length | 43.9 mm |
| Diameter | 18 mm |
| Thread size | M18 |
Classifications
System | Classcode |
ECLASS 13.0 | 27270901 |
ECLASS 12.0 | 27270901 |
ECLASS 11.0 | 27270901 |
ECLASS 10.0.1 | 27270901 |
ECLASS 9.0 | 27270901 |
ECLASS 8.0 | 27270901 |
ECLASS 5.1 | 27270901 |
ETIM 9.0 | EC002716 |
ETIM 8.0 | EC002716 |
ETIM 7.0 | EC002716 |
ETIM 6.0 | EC002716 |
ETIM 5.0 | EC002716 |
UNSPSC 12.1 | 39121528 |
Details:
GD18-S/GV18-S/73/120
Product Documentation:
GD18-S/GV18-S/73/120
Design / Simulation:
GD18-S/GV18-S/73/120
Approvals:
GD18-S/GV18-S/73/120
Produtos Relacionados:
GD18-S/GV18-S/73/120
Accessories |
|
|
|
Mounting flange, 18 mm, Retainer for all cylindrical sensors with M18 thread, Simple installation and exact setting, Large sensing range (max. 20 mm)fa |
|
|
|
|
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mmfa |
|
|
|
|
Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable greyfa |
|
|
|
|
Female cordset single-ended M12 angled A-coded, 4-pin, PUR cable greyfa |
|
|
|
|
Mounting Bracket with swivel nutfa |
|
|
|
|
Plastic mounting adapter, 18 mmfa |
|