Premium radar motion sensor with integrated self-monitoring for escape and emergency routes, can be operated remotely, detection range 2.5 m x 3.5 m, max. installation height 4 m, black housing, frequency output, cable connection |
General specifications | ||
---|---|---|
Sensing range | 2500 x 3500 mm (DxW) at 2200 mm mounting height and 0° inclination angle | |
Function principle | Microwave module | |
Detection speed | min. 0.1 m/s | |
Setting angle | 0 ... 10 ° in 5 ° increments | |
Operating frequency | 24.05 ... 24.25 GHz K-Band | |
Operating mode | Radar motion sensor | |
Transmitter radiated power (EIRP) | < 20 dBm | |
Functional safety related parameters | ||
Performance level (PL) | PL d | |
Category | Cat. 3 | |
MTTFd | 850 a | |
PFHd | 6.46 E-8 | |
Diagnostic Coverage (DC) | 60 % | |
Indicators/operating means | ||
Function indicator | LED red/green , LED Row green | |
Control elements | Navigation key or Programming via menu driven remote control | |
Factory setting | sensitivity adjustment : 7 cross-traffic suppression : 1 immunity : 2 |
|
Electrical specifications | ||
Operating voltage | 12 ... 36 V DC | |
No-load supply current | < 200 mA at 24 V DC | |
Power consumption | < 3 W | |
Inrush current | 900 mA | |
Output | ||
Switching type | NO/NC | |
Signal output | Frequency output | |
Output 3 | ||
Output type | Frequency output | |
Output current | max. 50 mA | |
Residual voltage | ≤ 2 V DC | |
Pulse/Pause ratio | 1:1 , deviation max. 10 % | |
Output frequency | 100 Hz | |
Compliance with standards and directives | ||
Directive conformity | ||
R&TTE Directive 1995/5/EC | This device can be used in all countries within the European Union with the exception of Great Britain and France. In other countries, all applicable national regulations must be observed. | |
Standard conformity | ||
Standards | 1999/5/EG; EN 62311, EN 60950-1, EN 301 489-1, EN 301 489-3, EN 300 440-2 Additionally: EN 61508; EN 13849-1; DIN EN 18650-1; DIN EN 18650-2; AutSchR 1997/12 | |
Ambient conditions | ||
Operating temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -30 ... 70 °C (-22 ... 158 °F) | |
Relative humidity | max. 90 % non-condensing | |
Mechanical specifications | ||
Mounting height | max. 3000 mm | |
Degree of protection | IP54 | |
Connection | 8-pin strip connector with cable 3 m connecting cable included with delivery |
|
Material | ||
Housing | ABS, anthracite | |
Mass | 140 g | |
Dimensions | ||
Height | 65 mm | |
Width | 123 mm | |
Depth | 57 mm | |
Suitable series | ||
Series | RMS |
System | Classcode |
---|---|
ECLASS 13.0 | 27274501 |
ECLASS 12.0 | 27280890 |
ECLASS 11.0 | 27280890 |
ECLASS 10.0.1 | 27280890 |
ECLASS 9.0 | 27280890 |
ECLASS 8.0 | 27280890 |
ECLASS 5.1 | 27270990 |
ETIM 9.0 | EC004807 |
ETIM 8.0 | EC000138 |
ETIM 7.0 | EC000138 |
ETIM 6.0 | EC000138 |
ETIM 5.0 | EC000138 |
UNSPSC 12.1 | 39121528 |
We are sorry, there are no documents for your language selection. Please select another language. |
Manuals | Jazyk | Typ souboru | Velikost souboru |
---|---|---|---|
Manual RMS-FRW | ENG | 5457 KB |
CAD | Jazyk | Typ souboru | Velikost souboru |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 3730 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|