General specifications |
Signal type | Digital Output |
Functional safety related parameters |
Safety Integrity Level (SIL) | SIL 3 |
Supply |
Connection | loop powered |
Rated voltage | 19 ... 30 V DC loop powered |
Power dissipation | < 1 W |
Input |
Connection side | control side |
Connection | SL1: 8a(+), 7a(-) |
Rated voltage | 19 ... 30 V loop powered |
Current | ≤ 72 mA at Ui = 19 V, ≤ 50 mA at Ui = 30 V with 265 Ω output load ≤ 45 mA at Ui = 19 V, ≤ 31 mA at Ui = 30 V with shorted output ≤ 14 mA at Ui = 19 V, ≤ 11 mA at Ui = 30 V no load at output |
Inrush current | ≤ 200 mA after 100 µs |
Output |
Connection side | field side |
Connection | SL2: 5a(+), 5b(-) |
Internal resistor | ≤ 238 Ω |
Current | ≤ 45 mA |
Voltage | ≥ 12 V |
Open loop voltage | ≥ 22.7 V |
Output signal | These values are valid for the rated operating voltage 19 ... 30 V DC. |
Energized/De-energized delay | single operation: typ. 1.7 ms/50 µs; periodical: typ. 5 µs/50 µs |
Indicators/settings |
Display elements | LED |
Labeling | space for labeling at the front |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity |
Electromagnetic compatibility | NE 21:2006 For further information see system description. |
Degree of protection | IEC 60529:2001 |
Protection against electrical shock | EN 61010-1:2010 |
Ambient conditions |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications |
Degree of protection | IP20 |
Mass | approx. 100 g |
Dimensions | 12.5 x 106 x 128 mm (0.5 x 4.2 x 5.1 inch) (W x H x D) |
| Height | 106 mm |
| Width | 12.5 mm |
| Depth | 128 mm |
Mounting | on termination board |
Coding | pin 1 and 4 trimmed For further information see system description. |
Data for application in connection with hazardous areas |
EU-type examination certificate | BASEEFA 06 ATEX 0171X |
| Marking | II (1)G [Ex ia Ga] IIC, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I (-20 °C ≤ Tamb ≤ 60 °C)
|
| Output | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
| Voltage | 25.2 V |
| Current | 110 mA |
| Power | 693 mW |
Input | |
| Maximum safe voltage | 250 V (Attention! The rated voltage can be lower.) |
Certificate | PF 08 CERT 1048 X |
| Marking | II 3G Ex nA IIC T4 Gc |
Galvanic isolation | |
| Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
Directive conformity | |
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 |
International approvals |
FM approval | |
| Control drawing | 16-534FM-12 (cFMus) |
IECEx approval | |
| IECEx certificate | IECEx BAS 06.0031X |
| IECEx marking | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
General information |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |