Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
A teljes adatlap letöltése PDF formátumban:
Termék leírása |
---|
AS-Interface safety switch with guard locking and guard locking monitoring |
General specifications | ||
---|---|---|
Node type | Safety node | |
AS-Interface specification | V3.0 | |
Required gateway specification | ≥ V2.0 | |
Profile | S-7.B | |
IO code | 7 | |
ID code | B | |
ID1 code | F | |
ID2 code | E | |
guard-locking mode | working current | |
UL File Number | E179102 | |
Functional safety related parameters | ||
Performance level (PL) | PL d | |
B10d | 5 E+6 | |
Indicators/operating means | ||
LED FAULT | error display; LED red red: communication error |
|
LED POWER | AS-Interface voltage; LED green | |
Electrical specifications | ||
Auxiliary voltage | Guard locking magnet: 24 V DC +10/-15 % PELV | |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface | |
Rated operating current | ≤ 45 mA | |
Rated insulation voltage | 50 V | |
Input | ||
Number/Type | 2 safety-related inputs: 1 door-monitoring contact SK 1 Magnet-monitoring contact MC |
|
Supply | from AS-Interface | |
Output | ||
Number/Type | 1 guard locking magnet, 1 LED red, 1 LED green |
|
Supply | from external auxiliary voltage (in accordance with IEC 60742, PELV) | |
Current | 300 mA | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 62026-2:2013+A1:2019 | |
Standard conformity | ||
Degree of protection | EN 60529:2000 | |
AS-Interface | EN 62026-2:2013+A1:2019 | |
Functional safety | DIN EN 954-1, EN ISO 13849-1 (up to PLd) | |
Ambient conditions | ||
Ambient temperature | -20 ... 55 °C (-4 ... 131 °F) | |
Mechanical specifications | ||
approach speed | max. 20 m/min | |
Operating force | 35 N | |
Extraction force | 30 N (not interlocked) | |
retention force | 20 N | |
locking force | max. 2500 N 2000 N , FZh as per inspection policy GS-ET-19 |
|
insertion depth | ||
approach direction lateral | detected min. distance: 24.5 mm permissible caster: 5 mm |
|
approach direction from above | detected min. distance: 24.5 mm permissible caster: 5 mm |
|
Degree of protection | IP67 | |
Connection | connector M12 x 1 | |
Material | ||
Housing | Fiberglass-reinforced thermoplastic | |
actuating head | metal | |
cam | stainless steel | |
Mass | approx. 0.5 kg | |
Dimensions | ||
Height | 42 mm | |
Width | 40 mm | |
Length | 190 mm | |
Life span | 106 switching cycles |
System | Classcode |
---|---|
ECLASS 13.0 | 27272603 |
ECLASS 12.0 | 27272603 |
ECLASS 11.0 | 27272603 |
ECLASS 10.0.1 | 27272603 |
ECLASS 9.0 | 27272603 |
ECLASS 8.0 | 27272603 |
ECLASS 5.1 | 27272603 |
ETIM 9.0 | EC001599 |
ETIM 8.0 | EC001599 |
ETIM 7.0 | EC001599 |
ETIM 6.0 | EC001599 |
ETIM 5.0 | EC001599 |
UNSPSC 12.1 | 39121535 |
The VAA-2E3A-LIM1-PL-L-S-V1 safety switch with mechanical interlock and separate actuator is a safety switch with 2 inputs and 3 outputs. The contact monitoring and solenoid monitoring are available via the inputs. Evaluation takes place via a safety monitor. The outputs control the solenoid and the red and green LEDs.
Connection is via an M12 plug. The safety switch is supplied via the AS-Interface and AUX. The mechanical interlock functions according to the operating current principle. The mechanical interlock is activated by triggering the D0 AS-Interface output. The interlock release takes place through tension.
The mechanical override serves to unlock the safety switch with the use of tools. To protect against manipulation, the mechanical override is sealed by locking varnish.
The power LED indicates operating voltage, the fault LED indicates a device or communication error. For example, contact monitoring can be displayed via the controller with the red LED and the solenoid monitoring with the green LED.
Depending on the application, 4 different models of mechanical actuators can be ordered separately.
Brief Instructions | Nyelv | Fájltípus | Fájlméret |
---|---|---|---|
Instruction Manual VAA-2E3A-LIM1-...-V1 | ENG | 810 KB |
CAD | Nyelv | Fájltípus | Fájlméret |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 2027 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
Certificates | Tanúsítvány sz. | Nyelv | Fájltípus | Fájlméret |
---|---|---|---|---|
Canada, USA UL | E179102 | ALL | LINK | --- |
Worldwide AS-International Association AS-Interface | 84401 | ALL | 350 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-2389C | ALL | 109 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-7017 | ALL | 107 KB |
Software Tools | Megjelenési információ | Fájltípus | Fájlméret |
---|---|---|---|
SISTEMA SLB Library AS-Interface Safety / SISTEMA SLB Library AS-Interface Safety | ZIP | 622 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|