Inductive sensor NCB2-12GM40-E2-3G-3D

NCB2-12GM40-E2-3G-3D
  • 2 mm flush
  • ATEX-/IECEx-approvals for zone 2/22 (Ex ec/tc)

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

PDF 파일로 된 데이타 시트 다운로드:


데이타 시트 발췌: 기술 사양  NCB2-12GM40-E2-3G-3D

General specifications
Switching functionNormally open (NO)
Output typePNP
Rated operating distance2 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 1.62 mm
Actual operating distance1.8 ... 2.2 mm typ. 2 mm
Reduction factor rAl 0.3
Reduction factor rCu 0.17
Reduction factor r304 0.67
Reduction factor rBrass 0.35
Output type3-wire
Nominal ratings
Operating voltage10 ... 30 V DC
Switching frequency0 ... 2500 Hz
Hysteresis3 ... 15 % typ. 6 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 3 V
Voltage drop at IL
Voltage drop IL = 200 mA, switching element on1 ... 2 V typ. 1.5 V
Operating current≤ 200 mA
Off-state current0 ... 0.5 mA typ. 0.01 mA
No-load supply current≤ 15 mA
Time delay before availability≤ 100 ms
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1507 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN IEC 60947-5-2
Approvals and certificates
IECEx approval
Equipment protection level Gc (ec)IECEx TUR 21.0017X
Equipment protection level Dc (tc)IECEx TUR 21.0018X
ATEX approval
Equipment protection level Gc (ec)TÜV 20 ATEX 8523 X
Equipment protection level Dc (tc)TÜV 20 ATEX 8524 X
UL approvalcULus Listed, General Purpose, Class 2 Power Source
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection typecable
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP66 / IP67
Cable
Wire end ferrulesyes
Cable diameter4.6 mm ± 0.2 mm
Bending radius> 10 x cable diameter
MaterialPVC
Colorgrey
Number of cores3
Core cross section0.34 mm2
Length2 m
Mass88 g
Dimensions
Length40 mm
Diameter12 mm
General information
Scope of delivery2 self locking nuts in scope of delivery
Use in the hazardous areasee instruction manuals

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NCB2-12GM40-E2-3G-3D

Product Documentation: NCB2-12GM40-E2-3G-3D

Language Selection:
Safety and Security Documentation언어파일 타입파일 크기
Instruction manualENGPDF232 KB

Design / Simulation: NCB2-12GM40-E2-3G-3D

Language Selection:
CAD언어파일 타입파일 크기
CAD 3-D / CAD 3-DALLSTP57 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
EPLAN macro EDZ / EPLAN Makro EDZALLEDZ65 KB

Approvals: NCB2-12GM40-E2-3G-3D

Language Selection:
Certificates인증서 번호언어파일 타입파일 크기
Brasil BR TUV Rheinland Brazil Ex ecTÜV 22.0560 XALLPDF542 KB
Brasil BR TUV Rheinland Brazil Ex tcTÜV 23.0981 XALLPDF543 KB
Canada USA UL Ordinary LocationUL-US-2019259-3 / UL-CA-2015551-3ALLPDF288 KB
China SITIIAS CCC Ex Certificate Ex ec2024322315005977 (Pepperl+Fuchs Manufacturing s.r.o)ALLPDF4002 KB
China SITIIAS Ex tc CCC Ex Certificate2024322315005859 (Pepperl+Fuchs Manufacturing s.r.o)ALLPDF4082 KB
Europe TUV Rheinland ATEX ec 3GTÜV 20 ATEX 8523 XALLPDF683 KB
Europe TUV Rheinland ATEX tc 3DTÜV 20 ATEX 8524 XALLPDF5399 KB
Worldwide TUV Rheinland IECEx ecIECEx TUR 21.0017XALLLINK---
Worldwide TUV Rheinland IECEx tcIECEx TUR 21.0018XALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F)TDOC-5069BENGENGPDF1408 KB
EU-Declaration of conformityTDOC-5069CENGENGPDF1408 KB
EU-Declaration of conformityTDOC-5069DENGENGPDF1408 KB
UK-Declaration of conformityTDOC-6461BENGENGPDF1381 KB
UK-Declaration of conformityTDOC-6461CENGENGPDF1381 KB

관련문서: NCB2-12GM40-E2-3G-3D

Accessories

Mounting flange, 12 mmfa

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.