General specifications |
Sensing range | 30 ... 500 mm |
Adjustment range | 50 ... 500 mm |
Dead band | 0 ... 30 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 380 kHz |
Response delay | minimum : 25 ms factory setting: 45 ms |
Memory |
Non-volatile memory | EEPROM |
Write cycles | 100000 |
Indicators/operating means |
LED green | solid: Power on flashing: Standby mode or IO link communication |
LED yellow 1 | solid: Object in evaluation range flashing: Learning function, object detected |
LED yellow 2 | solid: Object in evaluation range flashing: Learning function, object detected |
LED red | solid red: Error red, flashing: program function, object not detected |
Electrical specifications |
Operating voltage | 10 ... 30 V DC , ripple 10 %SS |
No-load supply current | ≤ 60 mA |
Power consumption | ≤ 1 W |
Time delay before availability | ≤ 100 ms |
Interface |
Interface type | IO-Link |
Protocol | IO-Link V1.0 |
Transfer rate | Acyclical: typical 240 Bit/s |
Cycle time | min. 13.2 ms |
Mode | COM2 (38.4 kBit/s) |
Process data width | 16 bit |
SIO mode support | yes |
Input/Output |
Input/output type | 1 synchronization connection, bidirectional |
| 0 Level | 0 ... 1 V |
| 1 Level | 4 V ... UB |
| Input impedance | > 12 kΩ |
| Output current | < 12 mA |
| Pulse length | 0.5 ... 300 ms (level 1) |
| Pulse interval | ≥ 14 ms (level 0) |
Synchronization frequency | |
| Common mode operation | ≤ 70 Hz |
| Multiplex operation | ≤ 90 Hz / n , n = number of sensors , n ≤ 10 (factory setting: n = 5 ) |
Output |
Output type | 2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected |
Rated operating current | 200 mA , short-circuit/overload protected |
Voltage drop | ≤ 2.5 V |
Repeat accuracy | ≤ 0.1 % of full-scale value |
Switching frequency | ≤ 11 Hz |
Range hysteresis | 1 % of the adjusted operating range (default settings), programmable |
Temperature influence | ≤ 1.5 % from full-scale value (with temperature compensation) ≤ 0.2 %/K (without temperature compensation) |
Compliance with standards and directives |
Standard conformity | |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
Approvals and certificates |
UL approval | cULus Listed, Class 2 Power Source |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Connection type | Connector plug M12 x 1 , 5-pin |
Degree of protection | IP67 |
Material | |
| Housing | Stainless steel 1.4305 / AISI 303 TPU Polyamides |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
Mass | 66 g |
Dimensions | |
| Length | 93 mm |
| Diameter | 30 mm |
Factory settings |
Output 1 | near switch point: 50 mm far switch point: 500 mm output function: Window mode output behavior: NO contact |
Output 2 | near switch point: 100 mm far switch point: 250 mm output function: Window mode output behavior: NO contact |
Beam width | wide |