Serviceline Industrial Sensors
Serviceline Explosion Protection

Optical reading head PXV100S-F200-SSI-Ex

PXV100S-F200-SSI-Ex
  • Explosion protection for use in Zone 1, Zone 2, Zone 21 and Zone 22
  • SSI interface
  • Non-contact positioning on Data Matrix code tape
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free
  • High resolution and precise positioning, especially for facilities with curves and switch points as well as inclines and declines.
  • Travel ranges up to 10 km

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

PDF 파일로 된 데이타 시트 다운로드:


데이타 시트 발췌: 기술 사양  PXV100S-F200-SSI-Ex

제품 설명
Optical reading head for hazardous area
General specifications
Passage speed≤ 8 m/s
Measuring lengthmax. 10000 m
Light typeIntegrated LED lightning (red)
Scan rate100 s-1
Read distance90mm (from outer housing window)
Depth of focus+ 20 mm / - 40 mm
Reading field115 mm x 73 mm
Ambient light limit100000 Lux
Accuracy± 0.2 mm
Nominal ratings
Camera
TypeCMOS , Global shutter
Processor
Clock pulse frequency600 MHz
Speed of computation4800 MIPS
Digital resolution32 Bit
Functional safety related parameters
MTTFd87 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED indication7 LEDs (communication, alignment aid, status information)
Electrical specifications
Operating voltage15 ... 30 V DC , PELV
No-load supply currentmax. 200 mA
Power consumption3 W
Interface 1
Interface typeSSI interface
Data output codeGray code, binary code , programmable
Monoflop time10 µs
Clock frequency100 ... 1000 kHz
Query cycle time≥ 3 ms
Pause time≥ 20 µs
Double check possiblewhen tp ≤ 10 µs
Interface 2
Interface typeUSB Service (serial comport)
Protocol8E1
Transfer rate38.4 ... 460.8 kBit/s
Input
Input type1 to 3 functional inputs , programmable
Input impedance≥ 27 kΩ
Output
Output type1 to 2 switch outputs , PNP , programmable , short-circuit protected
Switching voltageOperating voltage
Switching current150 mA each output
Standard conformity
Emitted interferenceEN 61000-6-4:2007+A1:2011    
Noise immunityEN 61000-6-2:2005    
Approvals and certificates
IECEx approvalIECEx INE 14.0042X
ATEX approvalINERIS 14 ATEX 0035X
Device type: GUBW1.D.OS-PXV100S-F200-SSI-V1
MarkingEx-Hexagon II 2 GD
Ex db IIC T6 Gb
Ex tb IIIC T85°C Db
CE conformityCE
UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure
Ambient conditions
Ambient temperature0 ... 55 °C (32 ... 131 °F)
Mechanical specifications
Connection typeConnection terminals, max. conductor cross-section 2.5 mm2
Conductor cross section0.13 ... 2.5 mm2
Cable gland3 ... 8.5 mm
Enclosure coverthreaded round cover
Cover fixingflamepath thread
Cover sealnone, O-ring for IP66/67
Degree of protectionIP66 (IP66/IP67 with O-ring)
Material
Enclosurealuminum alloy
Glassthermo-resistant tempered glass
Finishepoxy coated RAL 7005 (grey)
O-Ringsilicone
Massapprox. 7 kg
Dimensions
Height279 mm
Width202 mm
Depth134 mm
GroundingM6 external grounding points

Classifications

SystemClasscode
ECLASS 13.027270918
ECLASS 12.027270918
ECLASS 11.027270701
ECLASS 10.0.127270701
ECLASS 9.027270701
ECLASS 8.027270701
ECLASS 5.127270701
ETIM 9.0EC004672
ETIM 8.0EC002999
ETIM 7.0EC002999
ETIM 6.0EC002999
ETIM 5.0EC001852
UNSPSC 12.143211711

Details: PXV100S-F200-SSI-Ex

Product Documentation: PXV100S-F200-SSI-Ex

Language Selection:
Manuals언어파일 타입파일 크기
ManualENGPDF2703 KB

Design / Simulation: PXV100S-F200-SSI-Ex

Language Selection:
CAD언어파일 타입파일 크기
CAD 3-D / CAD 3-DALLSTP834 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ47 KB

Approvals: PXV100S-F200-SSI-Ex

Language Selection:
Certificates인증서 번호언어파일 타입파일 크기
Europe INERIS ATEXINERIS 14 ATEX 0035XALLPDF529 KB
Worldwide INERIS IECEx Certificate of ConformityIECEx INE 14.0042XALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4743CALLPDF372 KB

Software: PXV100S-F200-SSI-Ex

Language Selection:
Software ToolsRelease Info파일 타입파일 크기
Software Vision Configurator / Software Vision ConfiguratorV6.7.0ZIP65423 KB

관련문서: PXV100S-F200-SSI-Ex

Matching System Components
Data Matrix code tape, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
DataMatrix metal code bars for positioning PXV read heads with red illumination, High temperature resistance, High mechanical stability, Easily exchangeable, Chemically highly resistantfa
Accessories
Operating software for camera-based sensorsfa
Male cordset single-ended M12 straight A-coded, 8-pin, PUR cable black, shielded, UL-approved, drag chain suitablefa
Male cordset single-ended M12 straight A-coded, 8-pin, PUR cable black, shielded, UL-approved, drag chain suitablefa
Event markers for the PXV system, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
USB cable unit with power supply, Power supply for 95 - 230 V AC, For SSI interface, For PROFIBUS DP, For CANopen, For PROFINET, For EtherNet/IPfa
Functional Safety Hub from Pepperl+Fuchs

Several hundred products with a SIL/PL assessment, free tools, and brochures in one place: the "Functional Safety Hub" is your starting point when you have to implement safety functions.

Absolute positioning systems safePXV and safePGV

For the first time, the new absolute positioning systems safePXV and safePGV realize safety level SIL 3/PL e with a single sensor …