Serviceline Industrial Sensors
Serviceline Explosion Protection

Optical reader - safePGV PGV100A-F200-B28-V1D

PGV100A-F200-B28-V1D
  • SIL 3 (EN 61508)
  • Category 4 PL e (EN ISO 13849)
  • PROFINET interface
  • PROFIsafe interface
  • Safe, non-contact positioning on Data Matrix code tape
  • Traverse distance up to 100 km
  • Mechanically rugged: no wearing parts, long operating life, maintenance-free

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

PDF 파일로 된 데이타 시트 다운로드:


데이타 시트 발췌: 기술 사양  PGV100A-F200-B28-V1D

제품 설명
Read head for incident light positioning system
General specifications
Passage speed≤ 8 m/s
Measuring lengthmax. 100000 m
Light typeIntegrated LED lightning (red/blue)
Read distance100 mm
Depth of focus± 30 mm
Field of viewtyp. 120 mm x 80 mm
Ambient light limit30000 Lux
Accuracy
Non safety-related X, Y± 0.2 mm
Non safety-related angle α± 0.5 °
Safety-related XSee the original instructions
Nominal ratings
Camera
TypeCMOS , Global shutter
Processor
Clock pulse frequency600 MHz
Speed of computation4800 MIPS
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Reaction time165 ms
MTTF41 a
MTTFd104.74 a
Mission Time (TM)20 a
PFH1.09 E-8 typ.
Indicators/operating means
LED indication7 LEDs (communication, status messages)
Electrical specifications
Operating voltage20 ... 30 V DC , PELV
No-load supply currentmax. 300 mA
Power consumption6 W
Interface
Interface type100 BASE-TX
ProtocolPROFINET IO Real-Time (RT) Conformance class B
Transfer rate    100 MBit/s      
Conformity
Fieldbus standardPROFIsafe in accordance with IEC 61784-3-3; profile 2.4
Functional safetyEN ISO 13849-1:2015 ; EN 61508:2010  part 1-7 ; EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Shock resistanceEN 60068-2-27:2009
Vibration resistanceEN 60068-2-6:2008
Emitted interferenceEN 61000-6-4:2007+A1:2011
Noise immunityEN 61000-6-7:2015
Photobiological safetyRisk group 2 according to IEC 62471
Approvals and certificates
CE conformityCE
UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure
CCC approvalCCC approval / marking not required for products rated ≤36 V
TÜV approvalTÜV Rheinland 01/205/5669.01/20
Ambient conditions
Operating temperature0 ... 45 °C (32 ... 113 °F) ,   -20 ... 45 °C (-4 ... 113 °F) (noncondensing; prevent icing on the lens!)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity90 % , noncondensing
Altitudemax. 2000 m above MSL
Mechanical specifications
Connection type8-pin, M12x1 connector, standard
4-pin, M12x1 socket, D-coded (LAN)
4-pin, M12x1 socket, D-coded (LAN)
Degree of protectionIP67
Material
HousingPC/ABS
Massapprox. 200 g
Dimensions
Height70 mm
Width70 mm
Depth50 mm

Classifications

SystemClasscode
ECLASS 13.027270918
ECLASS 12.027310101
ECLASS 11.027310101
ECLASS 10.0.127310101
ECLASS 9.027310101
ECLASS 8.027310101
ECLASS 5.127310101
ETIM 9.0EC004672
ETIM 8.0EC001852
ETIM 7.0EC001852
ETIM 6.0EC001852
ETIM 5.0EC001852
UNSPSC 12.143211711

Details: PGV100A-F200-B28-V1D

Informative Literature: PGV100A-F200-B28-V1D

Language Selection:
Literature언어파일 타입파일 크기
Application Report - Precise Docking and Reliable Identification of AGVsENGPDF199 KB
Application Report - Reliable Position Determination for Automated Guided VehiclesENGPDF337 KB

Product Documentation: PGV100A-F200-B28-V1D

Language Selection:
Brief Instructions언어파일 타입파일 크기
Instruction leaflet / BeipackzettelALLPDF493 KB
Commissioning safePXV / safePGV Simatic S7 Profinet / PROFIsafeENGPDF12455 KB
Safety and Security Documentation
Instruction manualENGPDF120 KB
Instruction manualENGPDF2559 KB

Design / Simulation: PGV100A-F200-B28-V1D

Language Selection:
CAD언어파일 타입파일 크기
CAD 3-D / CAD 3-DALLSTP3926 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ317 KB

Approvals: PGV100A-F200-B28-V1D

Language Selection:
Certificates인증서 번호언어파일 타입파일 크기
Canada, USA UL Ordinary LocationE87056, Vol. 6ALLPDF521 KB
TUV Rheinland Functional Safety Certificate01_205_5669_01_20_en_elALLPDF693 KB
Worldwide PNO Certificate of ComplianceZ12240ALLPDF82 KB
Worldwide PNO Certificate of ComplianceZ20215ALLPDF216 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4079AALLPDF35 KB

Software: PGV100A-F200-B28-V1D

Language Selection:
Device Description Files/DriversRelease Info파일 타입파일 크기
GSDML file for PGV B28 Profisafe / GSDML-Datei für PGV B28 Profisafe08/2020ZIP8 KB

관련문서: PGV100A-F200-B28-V1D

Matching System Components

Protective laminate for PGV code tape, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
Data Matrix code tape, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
Blind plug for M12 socketsfa
Protective laminate for PGV code tape, High chemical resistance, Low weight, Self-adhesive mounting, High temperature resistance, High mechanical stabilityfa
Accessories

Alignment guide for readerfa

Female connector M12 straight A-coded 8-pin, for cable diameter 5 - 8 mm, shielded, field-attachablefa

Female cordset single-ended M12 straight A-coded, 8-pin, PUR cable grey, shieldedfa

Female cordset single-ended M12 straight A-coded, 8-pin, PUR cable grey, shieldedfa
Grounding clip for PCV system, Stainless steel version, Low weight, M12 plug connection, High mechanical stabilityfa
Grounding clip for PCV system, Stainless steel version, Low weight, M12 plug connection, High mechanical stabilityfa
Marker head for 25 mm code tape, For 25 mm code tapes, Can be used for PCV80..., PCV100..., and PCV130... readers, Includes 2 x edding® 3000 permanent markersfa
Mounting bracket for PCV* read headfa
Female connector, M12, 8-pin, shielded, field attachablefa
Functional Safety Hub from Pepperl+Fuchs

Several hundred products with a SIL/PL assessment, free tools, and brochures in one place: the "Functional Safety Hub" is your starting point when you have to implement safety functions.

Absolute positioning systems safePXV and safePGV

For the first time, the new absolute positioning systems safePXV and safePGV realize safety level SIL 3/PL e with a single sensor …