Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
PDF 파일로 된 데이타 시트 다운로드:
제품 설명 |
---|
Measuring automation light grid with beam spacing of 25 mm, IO-Link interface, push-pull output, fixed cable with M12 plug |
General specifications | ||
---|---|---|
Effective detection range | Standard : 0.3 ... 6 m | |
Threshold detection range | 7.5 m | |
Light source | IRED | |
Light type | modulated infrared light , 850 nm | |
Field height | see Table 1, max. 3200 mm | |
Beam crossover | Factory setting: three beam crossing, deactivateable | |
Beam blanking | adjustable max. 2 fixed suppressible beam areas (blanking) | |
Beam spacing | 25 mm | |
Number of beams | see Table 1, max. 129 | |
Operating mode | Emitter: Emitter power adjustable in two ranges | |
Optical resolution | without beam crossover: 25 mm with beam crossover: 12.5 mm with in 25% and 75% of the range |
|
Opening angle | 10 ° | |
Ambient light limit | > 50000 Lux (if external light source is outside the opening angle) | |
Functional safety related parameters | ||
MTTFd | 34 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 60 % | |
Indicators/operating means | ||
Operation indicator | LED green: constantly on - power-on double pulse flashing (0.8 Hz) - undervoltage flashing (4 Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
|
Status indicator | Emitter: LED yellow constantly on - high emitter power constantly off - low emitter power flashing (8 Hz) - error message Receiver: LED yellow: constantly on - object detected constantly off - no object detected flashing (4 Hz) - falling below operating reserve flashing (8 Hz) - error message |
|
Control elements | Receiver: 2 touch buttons for programming | |
Electrical specifications | ||
Operating voltage | 18 ... 30 V DC | |
Ripple | 10 % | |
No-load supply current | Emitter ≤: 50 mA Receiver: ≤ 150 mA (without outputs) |
|
Time delay before availability | see Table 1, max. 2.3 s | |
Interface | ||
Interface type | IO-Link ( pin 4 ) | |
IO-Link revision | 1.0 | |
Device ID | 1050369 ... 1050400 ( 0x100701 ... 0x100720 ) | |
COM-Mode | COM2 (38.4 kBit/s) | |
Min. cycle time | 2.3 ms | |
Process data width | 16 bit | |
SIO mode support | yes | |
Input | ||
Test input | Emitter switch-off with +UB or 0 V at pin 4 (emitter) | |
Function input | Range input activation from 1.6 m with +UB or 0 V on pin 2 (emitter) Teach-In input for parameterization on pin 8 (receiver) |
|
Output | ||
Stability alarm output | Stability Control (SC) 1 PNP, short-circuit protected, reverse polarity protected on pin 2 (receiver) | |
Switching type | Factory setting: dark on , Switchable to light-on mode | |
Signal output | Command interface: Pin 4 IO-Link interface C or used as switching output Q; 1 short-circuit proof reverse polarity protected push-pull output (receiver) Switch output: Pin 5 switching output Q; 1 short-circuit proof reverse polarity protected push-pull output (receiver) synchronized with pin 4 |
|
Switching threshold | Factory setting: The signal tracking for the threshold value is deactivated, increasing the optical resolution by a maximum of 4 mm; switchable to active signal tracking | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA | |
Voltage drop | ≤ 2 V DC | |
Switching frequency | see Table 1, max. 135 Hz | |
Response time | see Table 1, max. 12 ms | |
Timer function | Off-delay programmable from 0 ... 1.25 s in 5 ms steps (adjustment via IO-Link only) | |
Conformity | ||
Communication interface | IEC 61131-9 | |
Product standard | EN 60947-5-2 | |
Approvals and certificates | ||
Protection class | III ( IEC 61140 ) | |
UL approval | cULus Listed | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
Ambient conditions | ||
Ambient temperature | -30 ... 60 °C (-22 ... 140 °F) | |
Storage temperature | -30 ... 70 °C (-22 ... 158 °F) | |
Mechanical specifications | ||
Conductor cross section | min. 0.25 mm2 | |
Housing length L | see Table 1, max. 3360 mm | |
Degree of protection | IP67 | |
Connection | Emitter: connecting cable with 4-pin, M12 x 1 connector , 330 mm total length Receiver: connecting cable with 8-pin, M12 x 1 connector , 350 mm total length |
|
Material | ||
Housing | extruded aluminum section , Silver anodized | |
Optical face | Plastic pane , Polycarbonate | |
Mass | see Table 1, max. 1750 g (per profile) | |
Dimensions | ||
Width | 20 mm | |
Depth | 30.5 mm | |
Cable length | max. 30 m |
System | Classcode |
---|---|
ECLASS 13.0 | 27270910 |
ECLASS 12.0 | 27270910 |
ECLASS 11.0 | 27270910 |
ECLASS 10.0.1 | 27270910 |
ECLASS 9.0 | 27270910 |
ECLASS 8.0 | 27270910 |
ECLASS 5.1 | 27270910 |
ETIM 9.0 | EC002549 |
ETIM 8.0 | EC002549 |
ETIM 7.0 | EC002549 |
ETIM 6.0 | EC002549 |
ETIM 5.0 | EC002549 |
UNSPSC 12.1 | 39121528 |
Literature | 언어 | 파일 타입 | 파일 크기 |
---|---|---|---|
Brochure - Automation Light Grids: LGS and LGM Series | ENG | 1965 KB |
Product information | 언어 | 파일 타입 | 파일 크기 |
---|---|---|---|
Installation and user instructions for offline parameterization of IO-Link sensors | ENG | 1788 KB | |
Brief Instructions | |||
Brief Instructions - LGM series | ENG | 1759 KB | |
Manuals | |||
Manual Measuring Automation Light Grid LGM | ENG | 6975 KB |
Certificates | 인증서 번호 | 언어 | 파일 타입 | 파일 크기 |
---|---|---|---|---|
Canada USA UL Ordinary Location | E87056 | ALL | LINK | --- |
Canada USA UL Ordinary Location | UL-CA-2134531-0 / UL-US-2141152-0 | ALL | 544 KB | |
IO-Link Manufacturer Declaration | PF 13 CERT 2915 | ALL | 36 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-0227B | ALL | 184 KB | |
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-0227C | ALL | 304 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-5336 | ALL | 228 KB |
Device Description Files/Drivers | Release Info | 파일 타입 | 파일 크기 |
---|---|---|---|
IODD for LGM series / IODD für LGM Serie | V1.01.000 / 2018-08-15 | ZIP | 2631 KB |
Device DTM for LGM IO-Link sensors / Geräte-DTM für LGM IO-Link Sensoren | V1.0.2.5 | ZIP | 3905 KB |
Software Tools | |||
IO-Link Offline Parameterization Tool / IO-Link Offline-Parametriertool | V1.00.006 / 2022-07-10 | ZIP | 96138 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|