Serviceline Industriële Sensoren
Telefoon +32 3 644 25 00
Serviceline Explosiebeveiliging
Telefoon +32 3 644 25 00

Vibration sensor VIM62PL-E0T16-0ME-I420V14

VIM62PL-E0T16-0ME-I420V14
  • Extended temperature range
  • Screw-in thread for simple installation
  • Simple electrical commissioning
  • Rugged stainless steel housing
  • Vibration velocity in mm/s (rms) acc. to DIN ISO 10816/20816
  • Detection of low frequency vibrations
  • Additional output with measured temperature value

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

De complete datasheet als PDF downloaden:


Technische gegevens  VIM62PL-E0T16-0ME-I420V14

Productbeschrijving
Vibration sensor with analog current output and increased temperature resistance
General specifications
TypeVibration sensor
Measuring technologyMEMS
SeriesPerformance Line
Measured variableVibration velocity
Temperature
Measuring range
Vibration velocity0 ... 16 mm/s
Temperature-40 ... 125 °C (-40 ... 257 °F)
Measurement accuracy± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz)
Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s
Cross-sensitivity< 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis
Frequency range1 ... 1000 Hz
Averaging timefor v-rms: 12 s
Electrical specifications
Fusingexternal fuse is required: 3 A , semi-time-lag , 30 V DC
Operating voltage10 ... 30 V DC
Current consumptionmax. 50 mA
Power consumptionmax. 750 mW
Time delay before availability10 s (rms filter is calculated intially with measurement data before they are available at the output)
Surge protectionup to 2 kV
Output 1
Output typeanalog output, current
output of the vibration variable
Output current4 ... 20 mA
Load resistor≤ 500 Ω
Output 2
Output typeanalog output, current
output of the temperature
Output current4 ... 20 mA
Load resistor≤ 500 Ω
Standard conformity
Degree of protectionDIN EN 60529, IP66, IP67
Shock resistanceDIN EN 60068-2-27, 60 g, 6 ms
Vibration resistanceDIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz
Vibration evaluationDIN ISO 10816/20816
Approvals and certificates
UL approval
Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request
Maximum permissible ambient temperaturemax. 60 °C (max. 140 °F)
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Measuring head temperature-40 ... 125 °C (-40 ... 257 °F) directly at the mounting point
Storage temperature-40 ... 60 °C (-40 ... 140 °F)
Mechanical specifications
Connection typeplug
Housing materialStainless steel 1.4305 / AISI 303
Degree of protectionIP66 / IP67 only in connected state
Connector
ThreadingM12
Number of pins4
Massapprox. 200 g
Dimensions
Length82.35 mm
Diameter31 mm

Classifications

SystemClasscode
ECLASS 13.027271103
ECLASS 12.027201406
ECLASS 11.027201406
ECLASS 10.0.127201406
ECLASS 9.027201406
ECLASS 8.027201406
ECLASS 5.127201406
ETIM 9.0EC004309
ETIM 8.0EC004309
ETIM 7.0EC002959
ETIM 6.0EC002959
ETIM 5.0EC001758
UNSPSC 12.141114624

Details: VIM62PL-E0T16-0ME-I420V14

Informative Literature: VIM62PL-E0T16-0ME-I420V14

Taalkeuze:
LiteratureTaalBestandstypeBestandsgrootte
Product Overview - Vibration SensorsENGPDF1351 KB

Product Documentation: VIM62PL-E0T16-0ME-I420V14

Taalkeuze:
Brief InstructionsTaalBestandstypeBestandsgrootte
Instruction leaflet / BeipackzettelALLPDF252 KB
Safety and Security Documentation
HandleidingHOLPDF149 KB
Manuals
Manual VIM6*-Vibration SensorsENGPDF2498 KB

Design / Simulation: VIM62PL-E0T16-0ME-I420V14

Taalkeuze:
CADTaalBestandstypeBestandsgrootte
CAD 3-D / CAD 3-DALLSTP1973 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ67 KB

Approvals: VIM62PL-E0T16-0ME-I420V14

Taalkeuze:
CertificatesCertificaatnummerTaalBestandstypeBestandsgrootte
Canada, USA UL Ordinary LocationE468231ALLPDF610 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-5277AALLPDF324 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-5593AALLPDF248 KB

Aanverwante producten: VIM62PL-E0T16-0ME-I420V14

Accessories
Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable grey, shieldedfa
Protective rubber sleeve for VIM6* vibration sensors against ingress of moisture and mechanical effectsfa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M8 x 1.25, screw-in depth 19.5fa
Mounting adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread M10 x 1.5, screw-in depth 18fa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M30 x 3.5, screw-in depth 45fa
Mounting adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread NPT1/2", screw-in depth 24fa
EMC adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread M8 x 1.25, screw-in depth 8fa
Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable black, shielded, UL approved, drag chain suitablefa
Mounting adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread M6 x 1.0, screw-in depth 10fa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M16 x 2.0, screw-in depth 27fa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M20 x 2.5, screw-in depth 34fa
Mounting adapter for VIM3*/VIM6*/VIM8* vibration sensors, internal thread M8 x 1.25 x 10, external thread M24 x 3.0, screw-in depth 40fa
Magnetic adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, holding force 35 kgfa
IO-Link converter with analog input (current/voltage)fa