Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
De complete datasheet als PDF downloaden:
Productbeschrijving |
---|
Wireless Access Point in aluminum alloy enclosure for use in explosion-hazardous areas |
Electrical specifications | ||
---|---|---|
Operating voltage | 1500 V DC / 1000 V AC max. | |
Operating current | recommended: 1600 A max. | |
Mechanical specifications | ||
Thread type | metric ISO pitch 1.5 mm or NPT ANSI ASME B1.20.1 | |
Enclosure cover | threaded round cover | |
Cover fixing | flamepath thread | |
Cover seal | none, O-ring for IP66/67 | |
Degree of protection | IP66 (IP66/IP67 with O-ring) | |
Material | ||
Enclosure | aluminum alloy | |
Finish | epoxy coated RAL 7005 (grey) | |
O-Ring | silicone | |
Mass | 21 kg | |
Dimensions | 360 mm x 360 mm x 219 mm values might differ slightly due to casting and manufacturing tolerances |
|
Mounting | see datasheets of relevant enclosures | |
Grounding | M6 external grounding points | |
Ambient conditions | ||
Ambient temperature | -40 ... 50 °C (-40 ... 122 °F) depending on integrated components |
|
Data for application in connection with hazardous areas | ||
EU-type examination certificate | INERIS 14 ATEX 0035X | |
Marking | II 2 GD Ex db IIC T* Gb Ex tb IIIC T** °C Db T6/T85 °C T5/T100 °C T4/T135 °C T3/T200 °C depending on configuration, ambient temperature and built-in power loss |
|
International approvals | ||
IECEx approval | IECEx INE 14.0042X | |
Further approvals | available on request | |
Conformity | ||
Degree of protection | EN 60529 | |
CE marking | 0080 or 0102, see type label | |
General information | ||
Ordering information | This Wireless Access Point solution will be delivered completely configured and assembled ready for use. For configuration details please contact customer service. | |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. | |
General specifications | ||
Installed components | All major WI-FI Access Point vendors such as Aruba, Cisco, ect. |
System | Classcode |
---|---|
ECLASS 13.0 | 27180502 |
ECLASS 12.0 | 27180502 |
ECLASS 11.0 | 27180502 |
ECLASS 10.0.1 | 27180502 |
ECLASS 9.0 | 27180502 |
ECLASS 8.0 | 27180508 |
ECLASS 5.1 | 27180502 |
ETIM 9.0 | EC002503 |
ETIM 8.0 | EC002503 |
ETIM 7.0 | EC002503 |
ETIM 6.0 | EC002503 |
ETIM 5.0 | EC002503 |
UNSPSC 12.1 | 39121314 |
Brief Instructions | Taal | Bestandstype | Bestandsgrootte |
---|---|---|---|
Brief Instructions - GUB* / GUBX* | ENG | 316 KB |
Certificates | Certificaatnummer | Taal | Bestandstype | Bestandsgrootte |
---|---|---|---|---|
Europe INERIS ATEX | INERIS 14 ATEX 0035X | ALL | 529 KB | |
Worldwide INERIS IECEx Certificate of Conformity | IECEx INE 14.0042X | ALL | LINK | --- |