Area scanner with large detection range for detecting people and objects |
General specifications | ||
---|---|---|
Detection field | 500 mm x 500 mm at 2000 mm sensor range | |
Detection range min. | 100 ... 1200 mm | |
Detection range max. | 100 ... 2800 mm | |
Light source | 4 x IRED | |
Light type | modulated infrared light | |
Light spot representation | 43 mm x 43 mm at 2000 mm | |
Marking | CE | |
Operating mode | Background suppression | |
Functional safety related parameters | ||
MTTFd | 470 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Function indicator | LED red | |
Control elements | Sensing range adjuster | |
Electrical specifications | ||
Operating voltage | 15 ... 48 V DC | |
No-load supply current | 100 mA | |
Power consumption | 2.5 W | |
Output | ||
Switching type | light/dark on | |
Signal output | 2 PNP, complementary, short-circuit protected, open collectors | |
Switching voltage | 48 V DC | |
Switching current | 200 mA | |
Response time | 100 ms | |
De-energized delay | 200 ms | |
Compliance with standards and directives | ||
Standard conformity | ||
Product standard | IEC 60947-5-2 | |
Emitted interference | EN 61000-6-3 | |
Standards | EN 61000-6-2 without EN 61000-4-5, EN 61000-4-11 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -20 ... 75 °C (-4 ... 167 °F) | |
Mechanical specifications | ||
Mounting height | max. 2800 mm | |
Degree of protection | IP65 | |
Connection | Connector, Binder series 581, 5-pin | |
Material | ||
Housing | Makrolon GV30 black | |
Optical face | Glass, red | |
Mass | 320 g | |
Dimensions | ||
Height | 64 mm | |
Width | 150 mm | |
Depth | 52 mm | |
General information | ||
Scope of delivery | 2 m Connecting cable |
System | Classcode |
---|---|
ECLASS 13.0 | 27270913 |
ECLASS 12.0 | 27270913 |
ECLASS 11.0 | 27270913 |
ECLASS 10.0.1 | 27270913 |
ECLASS 9.0 | 27270913 |
ECLASS 8.0 | 27270913 |
ECLASS 5.1 | 27270903 |
ETIM 9.0 | EC002550 |
ETIM 8.0 | EC002550 |
ETIM 7.0 | EC002550 |
ETIM 6.0 | EC002550 |
ETIM 5.0 | EC001821 |
UNSPSC 12.1 | 39121528 |
The FLT-8 series active infra-red area scanners detect people and objects located within a defined sensing field, regardless of background and whether or not they are moving. The sensors generate a clearly defined spatial sensing field, which can be mechanically adjusted. This sensing field is comprised of three or four individual light beams.
We are sorry, there are no documents for your language selection. Please select another language. |
Brief Instructions | Nyelv | Fájltípus | Fájlméret |
---|---|---|---|
Instruction leaflet / Beipackzettel | ALL | 732 KB |
CAD | Nyelv | Fájltípus | Fájlméret |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 92 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
Declaration of Conformity | Tanúsítvány sz. | Nyelv | Fájltípus | Fájlméret |
---|---|---|---|---|
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-1138C | ALL | 307 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-5587 | ALL | 227 KB |