Serviceline Industrial Sensors
Serviceline Explosion Protection

Repeater KFD0-CS-Ex1.54-Y2

KFD0-CS-Ex1.54-Y2
  • 1-channel isolated barrier
  • 24 V DC supply (loop powered)
  • SMART fire alarm input
  • Current input 1 mA ... 20 mA

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

PDF 파일로 된 데이타 시트 다운로드:


데이타 시트 발췌: 기술 사양  KFD0-CS-Ex1.54-Y2

General specifications
Signal typeAnalog input
Supply
Rated voltage0 ... 24 V DC , loop powered
Power dissipation0.2 W
Control circuit
Connectionterminals 11+, 12-
Current0 ... 20 mA
Transmission rangecurrent: 1 ... 20 mA
voltage: 0 ... 24 V
Field circuit
Connectionterminals 1+, 2-
Short-circuit current≤ 43 mA
Transfer characteristics
Deviation
After calibration≤ 3.5 mA current loss at 20 mA load current
Influence of ambient temperature± 20 µA / K
Rise time/fall time≤ 50 µs (load current ≥ 1 mA)
Galvanic isolation
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Indicators/settings
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
Protection against electrical shockUL 61010-1
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Massapprox. 100 g
Dimensions20 x 107 x 115 mm (0.8 x 4.2 x 4.5 inch) (W x H x D) , housing type B1
Height107 mm
Width20 mm
Depth115 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificateBAS 00 ATEX 7087
MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
Voltage25.2 V
Current43 mA
Power271 mW
Supply
Maximum safe voltage250 V (Attention! The rated voltage can be lower.)
CertificateTÜV 99 ATEX 1499 X
MarkingEx-Hexagon II 3G Ex nA II T4
Galvanic isolation
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
FM approval
Control drawing116-0129 (cFMus)
UL approvalE106378
Control drawing116-0348 (cULus)
IECEx approval
IECEx certificateIECEx BAS 08.0079
IECEx BAS 10.0007X
IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
Ex nA IIC T4 Gc
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210123
ECLASS 12.027210120
ECLASS 11.027210120
ECLASS 10.0.127210120
ECLASS 9.027210120
ECLASS 8.027210120
ECLASS 5.127210120
ETIM 9.0EC002653
ETIM 8.0EC002653
ETIM 7.0EC002653
ETIM 6.0EC002653
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: KFD0-CS-Ex1.54-Y2

Informative Literature: KFD0-CS-Ex1.54-Y2

Language Selection:
Literature언어파일 타입파일 크기
Application Report - Energy Generation in Wastwater Treatment PlantsENGPDF532 KB
Application Report - Generating Electricity in Coal-Fired Power PlantsENGPDF412 KB
Application Report - Screening Systems in Sewage Treatment PlantsENGPDF577 KB
Application Report - Sicherer Brennstofftransport in KohlekraftwerkenENGPDF391 KB
Application Report - Water Inlet in Wastewater Treatment PlantsENGPDF526 KB

Product Documentation: KFD0-CS-Ex1.54-Y2

Language Selection:
Safety and Security Documentation언어파일 타입파일 크기
Instruction manualENGPDF173 KB
Functional Safety ManualENGPDF462 KB
Manuals
ManualENGPDF3685 KB

Design / Simulation: KFD0-CS-Ex1.54-Y2

Language Selection:
CAD언어파일 타입파일 크기
CAD 3-D / CAD 3-DALLSTP1871 KB
CAD Portal / CAD PortalALLLINK---

Approvals: KFD0-CS-Ex1.54-Y2

Language Selection:
Certificates인증서 번호언어파일 타입파일 크기
Baseefa IECEx Certificate of ConformityIECEx BAS 08.0079ALLLINK---
Baseefa Type n IECEx Certificate of ConformityIECEx BAS 10.0007XALLLINK---
Brasil TUV RheinlandTÜV 15.0794ALLPDF1134 KB
Canada FMFM18CA0107XALLPDF322 KB
Canada UL cULE106378 cUL (QUZW7)ALLLINK---
Canada UL cULE106378 cUL (QVAJ7)ALLLINK---
China SITIIAS CCC Ex Certificate2021322316004085 (Singapore)ALLPDF1937 KB
DNV MarineTAA00001WXALLPDF106 KB
Europe Baseefa ATEX Category (1) GDBAS 00 ATEX 7087ALLPDF346 KB
USA FMFM 18 US 225XALLPDF322 KB
USA ULE106378 UL (QUZW)ALLLINK---
USA ULE106378 UL (QVAJ)ALLLINK---
Ukraine SERTIS ExSC 21.0646 XALLPDF12351 KB
United Kingdom Baseefa UKEX Category (1) D UKEX Category (1) G UKEX Category (M1)BAS21UKEX0426ALLPDF334 KB
Control Drawings
Control drawing CSA / Control drawing CSA   ALLPDF56 KB
Control drawing FM / Control drawing FM   ALLPDF58 KB
Declaration of Conformity
EU Declaration of Conformity (P+F)TDOC-0035FENGENGPDF185 KB
UK Declaration of Conformity (P+F)TDOC-7080AENGENGPDF153 KB

관련문서: KFD0-CS-Ex1.54-Y2

Matching System Components
Cable trunking is integrated in the mounting profile, Safe spacious separation of safe and hazardous signals, No additional cable guides necessary, Standard length 1.8 m (5.8 ft), simple to customize to application space, With mounting aidspa
Accessories
3-pin screw terminal, For KF modules of K-System, Packaging unit: 5 pieces greenpa
3-pin screw terminal, For KF modules of K-System, Packaging unit: 5 pieces bluepa
Coding of K-System terminal blocks, Coding of LB/FB-System front sockets, Packaging unit: 20 x 6 coding pinspa
Safety Products Selector

Choose from various selection criteria like safety integrity level, performance level, device function, and signal type and find the SIL/PL assessed device that you are looking for.