Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
De complete datasheet als PDF downloaden:
Productbeschrijving |
---|
Robust, compact, long range photoelectric sensors for detecting people, objects and vehicles |
General specifications | ||
---|---|---|
Effective detection range | 0 ... 12 m | |
Reflector distance | 0.04 ... 12 m | |
Threshold detection range | 14 m | |
Reference target | H85-2 reflector | |
Light source | LED | |
Light type | modulated visible red light , 640 nm | |
Diameter of the light spot | approx. 35 mm at a distance of 12 m | |
Opening angle | ± 1 ° | |
Ambient light limit | 90000 Lux | |
Functional safety related parameters | ||
MTTFd | 1460 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Function indicator | LED red illuminates: when beam is free flashes: when level falls below operating reserve off: when beam is interrupted |
|
Electrical specifications | ||
Operating voltage | 24 ... 230 V AC/DC | |
Ripple | 10 % | |
No-load supply current | ≤ 8.5 mA | |
Power consumption | 0.2 W at 24 V DC , 1.8 W at 230 V AC 3 VA | |
Output | ||
Switching type | light-on | |
Signal output | Relay, 1 alternator | |
Switching voltage | 230 V AC | |
Switching current | max. 2 A | |
Switching frequency | 7 Hz | |
Response time | 50 ms | |
Conformity | ||
Product standard | EN 60947-5-2 | |
Approvals and certificates | ||
CE conformity | yes | |
UL approval | cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. |
|
CCC approval | Certified by China Compulsory Certification (CCC) | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Connection | terminal compartment | |
Material | ||
Housing | plastic | |
Optical face | Plastic pane | |
Mass | 100.7 g | |
Dimensions | ||
Height | 88 mm | |
Width | 25.8 mm | |
Depth | 65.5 mm | |
Note | Safety fuse ≤ 2 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
System | Classcode |
---|---|
ECLASS 13.0 | 27270902 |
ECLASS 12.0 | 27270902 |
ECLASS 11.0 | 27270902 |
ECLASS 10.0.1 | 27270902 |
ECLASS 9.0 | 27270902 |
ECLASS 8.0 | 27270902 |
ECLASS 5.1 | 27270902 |
ETIM 9.0 | EC002717 |
ETIM 8.0 | EC002717 |
ETIM 7.0 | EC002717 |
ETIM 6.0 | EC002717 |
ETIM 5.0 | EC002717 |
UNSPSC 12.1 | 39121528 |
We are sorry, there are no documents for your language selection. Please select another language. |
Brief Instructions | Taal | Bestandstype | Bestandsgrootte |
---|---|---|---|
Instruction leaflet / Beipackzettel | ALL | 396 KB |
CAD | Taal | Bestandstype | Bestandsgrootte |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 213 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
Certificates | Certificaatnummer | Taal | Bestandstype | Bestandsgrootte |
---|---|---|---|---|
Canada USA UL Ordinary Location | UL-CA-L87056-31-52803002-0 / UL-US-L87056-11-52803002-0 | ALL | 545 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-4716A | ALL | 304 KB |
Kit | ||||||
---|---|---|---|---|---|---|
|
||||||
Accessories | ||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|