Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Faça o download das folhas de dados em PDF:
Folhas de dados: Dados técnicos do
R-SP-E12
Descrição do Produto |
Segment protector, junction box for fieldbus with short-circuit protection, Field junction box, module for DIN rail mounting |
General specifications |
Design / Mounting | Cabinet installation |
Installation in hazardous area | Zone 1 / Div. 2 |
Fieldbus connection |
Power dissipation | 250 mW |
Main cable (Trunk) | |
| Cable entry type | screw terminal , fixed |
| Rated voltage | 9 ... 32 V DC |
Outputs | |
| Number of outputs | 12 |
| Cable entry type | screw terminal , fixed |
| Rated voltage | max. 32 V |
| Rated current | max. 40 mA |
| Short-circuit current | max. 52 mA |
Self current consumption | max. 9 mA |
Voltage drop main cable/outputs | max. 1.3 V |
Terminating resistor | selectable 100 Ω integrated |
Surge protection | trunk, spurs overvoltage protected if voltage exceeds typ. 39 V, max. 41 V |
Indicators/operating means |
LED PWR | green: Fieldbus voltage > 10 V |
LED CHANNEL ERROR | red flashing: short-circuit |
LED COM | yellow: bus activity |
LED TERM ON | yellow: termination activated |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 |
Standard conformity |
Electromagnetic compatibility | NE 21:2006 |
Degree of protection | IEC 60529 |
Fieldbus standard | IEC 61158-2 |
Shock resistance | EN 60068-2-27 |
Vibration resistance | EN 60068-2-6 |
Ambient conditions |
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Relative humidity | 95 % non-condensing |
Shock resistance | 15 g , 11 ms |
Vibration resistance | 5 g , 10 ... 150 Hz |
Mechanical specifications |
Connection type | screw terminal , fixed |
Core cross section | max. 2.5 mm2 / AWG 12-24 |
Housing material | Polycarbonate |
Degree of protection | IP20 |
Mass | 800 g |
Dimensions | |
| Height | 100 mm |
| Width | 216 mm |
| Depth | 50 mm |
Mounting | DIN rail mounting |
Coating | resin filled |
Data for application in connection with hazardous areas |
EU-type examination certificate | PTB 04 ATEX 2100 X |
| Marking | II 2 G Ex eb mb IIC T4 Gb |
Maximum values | |
| Rated voltage | ≤ 35 V |
| Prospective short-circuit current | 100 A |
Directive conformity | |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN IEC 60079-7:2015+A1:2018 , EN 60079-18:2015+A1:2017 |
International approvals |
IECEx approval | IECEx PTB 05.0010X |
| Approved for | Ex eb mb IIC T4 Gb |
General information |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Classifications
System | Classcode |
ECLASS 13.0 | 27242610 |
ECLASS 12.0 | 27242610 |
ECLASS 11.0 | 27242610 |
ECLASS 10.0.1 | 27242610 |
ECLASS 9.0 | 27242610 |
ECLASS 8.0 | 27242610 |
ECLASS 5.1 | 27242601 |
ETIM 9.0 | EC001601 |
ETIM 8.0 | EC001601 |
ETIM 7.0 | EC001601 |
ETIM 6.0 | EC001601 |
ETIM 5.0 | EC001604 |
UNSPSC 12.1 | 39121008 |
Details:
R-SP-E12
Product Documentation:
R-SP-E12
Safety and Security Documentation | Idioma | Tipo de Arquivo | Tamanho do Arquivo |
Manual de instruções | POR | PDF | 221 KB
|
Produtos Relacionados:
R-SP-E12
Matching System Components |
|
|
|
Connection of Ex d certified devices, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 1 - increased safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|
|
|
|
Segment Protector Junction Box, Brushed Stainless Steel, Connection of Ex d certified devices, Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 1 - increased safety, Function: Device coupler, Design / Mounting: Outside installationpa |
|