Ethernet IO-Link module with eight IO-Link ports |
General specifications | ||
---|---|---|
UL File Number | E223772 | |
Indicators/operating means | ||
LED indication | see manual | |
Rotary switch | Setting the fieldbus protocol | |
Electrical specifications | ||
Rated operating voltage | 20 ... 30 V | |
Nominal voltage | 24 V DC (SELV/PELV) | |
Current consumption | typ. 160 mA ± 20 % at nominal voltage | |
Current loading capacity | max. 16 A per module | |
Interface | ||
Interface type | Industrial Ethernet | |
Physical | M12, D-coded | |
Protocol | PROFINET IO , EtherNet/IP , EtherCAT® , CC-Link IE Field Basic , MODBUS TCP | |
Transfer rate | Fast Ethernet 10/100 Mbps , full duplex | |
Inputs/Outputs | ||
Number/Type | 8 x IO-Link Class A (X1 – X8) Configurable as: Max. 8 IO-Link and 8 digital inputs/outputs Max. 16 digital inputs/outputs short-circuit protected |
|
Sensor supply | max. 4 A per port (X1 - X8) via L+ (pin 1) | |
Output current | max. 500 mA per port (X1 - X8) via C/Q (Ch. A/pin 4) max. 2 A per port (X1 - X8) via DO (Ch. B/pin 2) |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 55032 | |
Standard conformity | ||
Degree of protection | EN 60529:2000 | |
Fieldbus standard | Type 1 according to IEC 61131-2 | |
Shock resistance | EN 61131-2:2004 | |
Approvals and certificates | ||
UL approval | ||
Maximum permissible operating current | max. 9 A | |
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Relative humidity | max. 95 % | |
Altitude | 0 ... 2000 m | |
Shock and impact resistance | 50 g, 11 ms, all axes | |
Vibration resistance | 15 g at 5 - 500 Hz | |
Pollution degree | 3 | |
Mechanical specifications | ||
Contact elements | PA | |
Degree of protection | IP65 / IP67 / IP69K | |
Connection | Power Supply M12, L-coded Fieldbus M12, D-coded Inputs/Outputs M12, A-coded |
|
Material | ||
Contacts | CuSn, gold-plated CuNi, gold-plated |
|
Housing | Diecast zinc | |
Seal | FKM | |
Mass | 480 g | |
Tightening torque, fastening screws | 1 Nm | |
Tightening torque, cable gland | 0.5 Nm | |
Dimensions | ||
Height | 200 mm | |
Width | 59.6 mm | |
Length | 21 mm | |
Construction type | Field housing | |
Tightening torque of clamping screws | 0.5 Nm |
System | Classcode |
---|---|
ECLASS 13.0 | 27242608 |
ECLASS 12.0 | 27242608 |
ECLASS 11.0 | 27242608 |
ECLASS 10.0.1 | 27242608 |
ECLASS 9.0 | 27242608 |
ECLASS 8.0 | 27242608 |
ECLASS 5.1 | 27242608 |
ETIM 9.0 | EC001597 |
ETIM 8.0 | EC001597 |
ETIM 7.0 | EC001597 |
ETIM 6.0 | EC001597 |
ETIM 5.0 | EC001597 |
UNSPSC 12.1 | 32151705 |
Product information | Jazyk | Typ souboru | Velikost souboru |
---|---|---|---|
Difference ICE1-* / ICE11-* / Unterschied ICE1-* / ICE11-* | ALL | 1000 KB | |
Manuals | |||
Manual ICE11-8IOL-G60L-V1D | ENG | 11821 KB |
CAD | Jazyk | Typ souboru | Velikost souboru |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 8927 KB |
CAE | |||
CAE EPLAN Data Portal / CAE EPLAN Data Portal | ALL | LINK | --- |
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZ | ALL | EDZ | 49 KB |
Certificates | Číslo certifikátu | Jazyk | Typ souboru | Velikost souboru |
---|---|---|---|---|
Canada, USA UL | CoC E223772 RptRef E223772-20220705 | ALL | 340 KB | |
IO-Link Manufacturer Declaration | CERT-7407 | ALL | 187 KB | |
Korea | R-R-PF1-ICE118IOLG60LV | ALL | 279 KB | |
Declaration of Conformity | ||||
EU prohlášení o shodě | TDOC-7259ACZE | CZE | 196 KB | |
UK-Declaration of conformity | TDOC-7260AENG | ENG | 171 KB |
Device Description Files/Drivers | Informace o uvolnění | Typ souboru | Velikost souboru |
---|---|---|---|
EtherCAT ESI Files / EtherCAT ESI Dateien | 08/2024 | ZIP | 38 KB |
EtherNet/IP EDS Files / EtherNet/IP EDS Dateien | 06/2024 | ZIP | 24 KB |
PROFINET GSDML Files / PROFINET GSDML Dateien | 07/2024 | ZIP | 112 KB |
CC-Link CSPP Files / CC-Link CSPP Dateien | 09/2024 | ZIP | 53 KB |
Simplified AOIs (Add On Instructions) for Rockwell Automation Studio 5000. Read and Write a single parameter on an ICE1, ICE2, ICE11 or Allen Bradley IO-Link masters / Inbetriebnahmedatei_a | 2.0 Dec 19, 2023 | ZIP | 56091 KB |
Software Tools | |||
Function Blocks (Add-on Instructions) for ICE11 IO-Link master using EtherNet/IP protocol. Loads the process data into port-specific tags. Allen Bradley PLC with Studio 5000 required. Description file also included. / Inbetriebnahmedatei_a | 6 / 2023 | ZIP | 58096 KB |
Accessory of | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
Accessories | ||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
Bezplatně ke stažení: Oficiální zpráva o komunikačních protokolech založených na protokolu TCP (PDF)
Tato zdarma poskytovaná oficiální zpráva ve formátu PDF porovnává různé komunikační protokoly založené na protokolu TCP (AMQP, OPC UA, MQTT, REST API), které si našly cestu vzhůru a jsou považovány za faktory umožňující používat IIoT a realizovat průmysl 4.0. Získejte zdarma soubor ke stažení hned teď!