Product |
|
|
'PSE2-SC-02' terméket hozzáadta a kedvencekhez.
'PSE2-SC-02' termék már szerepel a kedvencek között.
|
Safety control unit, For evaluating safety thru-beam sensors PSE4-SL, Safety category 3 according to EN61496-1, 24 V DC supply voltage, 1 safe output contact, Performance level PLd (EN13849-1) is attainable, Component of PSE4 modular system, Number of channels: 4-channel, Performance level (PL): PL d, Category: Cat. 3, Operating voltage: 24 V DC +20/-10 % 24 V AC ± 10 %, Connection: screw terminals , lead cross section 2 x 1 mm2fa |
|
|
|
'PSE4-SC-01' terméket hozzáadta a kedvencekhez.
'PSE4-SC-01' termék már szerepel a kedvencek között.
|
Safety control unit, For evaluating safety thru-beam sensors PSE4-SL, Safety category 4 according to EN61496-1, 24 V DC supply voltage, 2 safe output contacts, Performance level PLe (EN13849-1) is attainable, Component of PSE4 modular system, Number of channels: 1-channel, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC +20/-10 %, Connection: screw terminals , Cable cross-section 0.2 ... 2.5 mm2fa |
|
|
|
'SB4 Cape' terméket hozzáadta a kedvencekhez.
'SB4 Cape' termék már szerepel a kedvencek között.
|
cover sheet, Cover for unused plug-in stations of the Safeboxfa |
|
|
|
'SB4 Housing 5' terméket hozzáadta a kedvencekhez.
'SB4 Housing 5' termék már szerepel a kedvencek között.
|
Empty housing for Evaluation unit SB4, Housing of the SafeBox with backplane for completionfa |
|
|
|
'SB4 Module 2E' terméket hozzáadta a kedvencekhez.
'SB4 Module 2E' termék már szerepel a kedvencek között.
|
OSSD-R/E-stop-module, Safety outputs OSSD, external status displays OSSD, 2 sensor channels, Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Stop function Cat.0 or Cat.1 and central stop function Cat.0, Time function, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
'SB4 Module 4C' terméket hozzáadta a kedvencekhez.
'SB4 Module 4C' termék már szerepel a kedvencek között.
|
Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
'SB4 Module 4CP' terméket hozzáadta a kedvencekhez.
'SB4 Module 4CP' termék már szerepel a kedvencek között.
|
Sensor module, 4 sensor channels, Single module for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), Micro-Controller controls, Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
'SB4 Module 4M' terméket hozzáadta a kedvencekhez.
'SB4 Module 4M' termék már szerepel a kedvencek között.
|
Muting module, 4 sensor channels, Double muting, Emergency muting for the correction of the material jam, Operating mode can be selected by means of DIP switches, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
'SB4 Module OR' terméket hozzáadta a kedvencekhez.
'SB4 Module OR' termék már szerepel a kedvencek között.
|
OSSD-R/Supply-module, Safety outputs OSSD, external status displays OSSD, Start/Restart disable , Operating mode can be selected by means of DIP switches, Relay monitor, Screw terminals or spring terminals, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC ± 20 % , via SB4 Housingfa |
|
|
|
'SB4-OR-4CP' terméket hozzáadta a kedvencekhez.
'SB4-OR-4CP' termék már szerepel a kedvencek között.
|
Evaluation device for safety thru-beam sensors SLA12 and SLA29 and for 2 channel safety devices (emergency off), 4 sensor channels, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Stability alarm indication, Clearly visible LED functional display, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC, ± 20 %fa |
|
|
| |