Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
De complete datasheet als PDF downloaden:
Productbeschrijving |
---|
USB fieldbus power supply for 1 or 2 field devices with D-sub socket for connecting to National Instruments NI PCMCIA FBUS card |
General specifications | ||
---|---|---|
Design / Mounting | Handheld/mobile | |
Installation in hazardous area | Zone 2 | |
Supply | ||
Connection | USB-Male Connector Typ A (Standard) | |
Rated voltage | typ. 5 V | |
Rated current | max. 350 mA | |
Power dissipation | typ. 250 mW | |
Fieldbus connection | ||
Connection | D-Sub socket 9-pin ; pin 6: Bus + , pin 7: Bus - | |
Rated voltage | min. 11 V | |
Rated current | 45 mA | |
Short-circuit current | typ. 60 mA | |
Terminating resistor | 50 Ω | |
Indicators/operating means | ||
LED ERR | red flashing: short-circuit or undervoltage at output | |
LED PWR | green: Interface Power ON/OK | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Standard conformity | ||
Degree of protection | IEC/EN 60529 | |
Fieldbus standard | IEC 61158-2 | |
Ambient conditions | ||
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Pollution degree | max. 2, according to IEC 60664 | |
Mechanical specifications | ||
Connection type | USB-Male Connector Typ A (Standard) | |
Housing | 56 x 32 x 17 mm | |
Housing material | Polycarbonate | |
Degree of protection | IP20 | |
Mass | approx. 105 g | |
Data for application in connection with hazardous areas | ||
Outputs | ||
Voltage | 17.5 V | |
Certificate | PF 08 CERT 1303 X | |
Marking | II 3G Ex nA II T4 | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 | |
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27242611 |
ECLASS 12.0 | 27242611 |
ECLASS 11.0 | 27242611 |
ECLASS 10.0.1 | 27242611 |
ECLASS 9.0 | 27242611 |
ECLASS 8.0 | 27242611 |
ECLASS 5.1 | 27242611 |
ETIM 9.0 | EC002583 |
ETIM 8.0 | EC002583 |
ETIM 7.0 | EC002583 |
ETIM 6.0 | EC002583 |
ETIM 5.0 | EC001604 |
UNSPSC 12.1 | 39121004 |
Literature | Taal | Bestandstype | Bestandsgrootte |
---|---|---|---|
Application Report - Controlling and Monitoring liquid Helium at the Deutsches Elektronen-Synchrotron | ENG | 361 KB | |
Application Report - Digital Communication in Steel-Plate Manufacturing | ENG | 470 KB |
Safety and Security Documentation | Taal | Bestandstype | Bestandsgrootte |
---|---|---|---|
Handleiding | HOL | 121 KB |
Certificates | Certificaatnummer | Taal | Bestandstype | Bestandsgrootte |
---|---|---|---|---|
Pepperl+Fuchs ATEX Category 3 G | PF 08 CERT 1303X | ALL | 206 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-0816C | ALL | 1039 KB |