Serviceline Industrial Sensors
Serviceline Explosion Protection

Trip amplifier S1SD-1AI-1R

S1SD-1AI-1R
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input bipolar current and voltage sources
  • Input 2-wire and 3-wire transmitters
  • Relay contact output
  • Restart inhibit
  • One-shot function
  • Configurable by DIP switches and software
  • Connection via screw terminals

请注意:所有以Pepperl + Fuchs GmbH或Pepperl + Fuchs AG名义发行的产品相关文件,例如证书,合格声明等,同样适用于Pepperl + Fuchs SE。

下载PDF版完整参数表:


技术参数节选  S1SD-1AI-1R

General specifications
Signal typeAnalog input
Supply
ConnectionPower Bus or terminals 1-, 2+
Rated voltage16.8 ... 31.2 V DC
Power dissipation0.6 W
Power consumption0.8 W
Interface
Programming interfaceprogramming socket
Input
Connection sidefield side
Transmission rangelinearity range:
unipolar -1 ... 110 %
bipolar -110 ... 110 %
Input I
Connectionterminals 5, 6, 7-
Input signal0/4 ... 20 mA , 0/2 ... 10 mA , ± 10 mA, ± 20 mA , max. 50 mA
Input resistance≤ 25 Ω
Input II
Connectionterminals 7-, 8+
Input signal0/1 ... 5 V , 0/2 ... 10 V , ± 5 V , ± 10 V , max. 30 V
Input resistance> 1 MΩ
Input III
Connectionterminals 5+, 6-
Input signal0/4 ... 20 mA
Available voltage16 V at 20 mA
Open circuit voltage/short-circuit current≤ 22 V / 30 mA
Input IV
Connectionterminals 5, 7
Input typereset restart inhibit
Output
Connection sidecontrol side
Connectionterminals 3, 4:
Outputsignal, relay
Contact loading253 V AC/2 A/cos φ > 0.7; 126.5 V AC/2 A/cos φ > 0.7; 30 V DC/2 A resistive load
Minimum switch current2 mA / 24 V DC
Energized/De-energized delay≤ 20 ms / ≤ 20 ms
Mechanical life107 switching cycles
Transfer characteristics
Accuracymax. 0.1 % of full-scale value
Influence of ambient temperature< 100 ppm/K of full-scale value
Galvanic isolation
Output/power supplysafe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min
Input/Other circuitssafe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min
Indicators/settings
Display elementsLEDs
Control elementsDIP switch
keys
Configurationvia DIP switches
via keys
via software
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EUEN 61010-1:2010
Conformity
Degree of protectionIEC 60529:2001
Protection against electrical shockEN 61010-1:2010
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Core cross section0.5 ... 2.5 mm2 (20 ... 14 AWG)
Massapprox. 70 g
Dimensions6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1
Height97 mm
Width6.2 mm
Depth107 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210122
ECLASS 12.027210122
ECLASS 11.027210122
ECLASS 10.0.127210122
ECLASS 9.027210122
ECLASS 8.027210122
ECLASS 5.127210122
ETIM 9.0EC002654
ETIM 8.0EC002654
ETIM 7.0EC002654
ETIM 6.0EC002654
ETIM 5.0EC001485
UNSPSC 12.132101514
Product category / 产品类的

Details: S1SD-1AI-1R

Informative Literature: S1SD-1AI-1R

选择语言:
Literature语言文件类型文件大小
Application Report - Sand Trap and Preliminary Sedimentation StageENGPDF448 KB
Product Overview SC-SystemENGPDF456 KB
Tender text
Tender textENGD816 KB

Product Documentation: S1SD-1AI-1R

选择语言:
Brief Instructions语言文件类型文件大小
Brief instructionsENGPDF251 KB
Safety and Security Documentation
Instruction manualENGPDF126 KB
Manuals
System ManualENGPDF2706 KB

Design / Simulation: S1SD-1AI-1R

选择语言:
CAD语言文件类型文件大小
CAD 3-D / CAD 3-DALLSTP4814 KB
CAD Portal / CAD PortalALLLINK---
CAE
EPLAN macros SC-System devices (EDZ) / EPLAN-Makros SC-System-Geräte (EDZ)ALLZIP4082 KB

Approvals: S1SD-1AI-1R

选择语言:
Declaration of Conformity证书号码语言文件类型文件大小
EU Declaration of Conformity (P+F)TDOC-2695CENGENGPDF172 KB

Software: S1SD-1AI-1R

选择语言:
Software ToolsRelease Info文件类型文件大小
Configuration software for SC-System: SC-Config / Konfigurations Software für SC-System: SC-Config3.4.0ZIP---

配套产品: S1SD-1AI-1R

Matching System Components
Interface for Power Bus, Supply current 3 A, LED status indication, Connection via screw terminalspa
Isolated USB interface cable, Used with SC-System devices, Configurable via PCpa
Bus carrier with bus PCB for 35 mm DIN mounting rail, height 7.5 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 250 mm (9.84 inch), simple to customize to application space, Eliminates daisy-chainspa
Bus carrier with bus PCB for 35 mm DIN mounting rail, height 15 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 250 mm (9.84 inch), simple to customize to application space, Eliminates daisy-chainspa
Cover for DIN mounting rail, Suitable for Power Bus, Standard length 250 mm (9.84 inch), simple to customize to application space, Packaging unit: 5 piecespa
Fixing of the bus carrier with bus PCB in the DIN mounting rail, Termination of DIN mounting rail, Suitable for Power Bus, Packaging unit: 5 pieces left, 5 pieces rightpa