请注意:所有以Pepperl + Fuchs GmbH或Pepperl + Fuchs AG名义发行的产品相关文件,例如证书,合格声明等,同样适用于Pepperl + Fuchs SE。
下载PDF版完整参数表:
General specifications | ||
---|---|---|
Measuring method | The device is a measuring system that functions according to the time-of-flight method. The distance from the reference point (process connection of the measuring device) to the product surface is measured. | |
Construction type | compact device | |
Series | LCR | |
Supply | ||
Rated voltage | 10.5 ... 30 V DC | |
Current consumption | input current : max. 25 mA start-up current : max. 3.6 mA |
|
Power consumption | input power : max. 675 mW | |
Electrical specifications | ||
Surge protection | integrated | |
Start-up time | first stable measured value after 20 s at 24 V DC | |
Interface 1 | ||
Interface type | HART | |
Specification | 7.0 | |
Supported functions | Additional Transmitter Status | |
Vendor ID | 0x005D | |
Device ID | 0x5DD3 | |
Coding | signal encoding, FSK ±0.5 mA over current signal | |
Transfer rate | 1200 Bit/s | |
Load | min. 250 Ω | |
Interface 2 | ||
Interface type | Bluetooth | |
Detection range | max. 25 m | |
Configuration | commissioning, operation and maintenance via P+F Level app - can be activated/deactivated - password encryption |
|
Communication | encrypted | |
Input | ||
Measured variable | distance between reference point and product surface | |
Measuring range | - device with 40 mm (1.5 inch) antenna: max. 15 m (49 foot) - device with 80 mm (3 inch) antenna: max. 20 m (66 foot) |
|
Operating frequency | approx. 26 GHz , K-Band | |
Transmitter radiated power | mean power density in the direction of the beam - at a distance of 1 m (3.3 foot): < 12 nW/cm2 - at a distance of 5 m (16 foot): < 0.4 nW/cm2 |
|
Output | ||
Output signal | 4 ... 20 mA , measured value output and power supply | |
Signal on alarm | current output: 22.5 mA (in accordance with NAMUR recommendation NE 43) operating tool via digital communication (HART) or P+F Level (app) - status signal (as per NAMUR Recommendation NE 107) - plain text display with remedial action |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | IEC 60529:2001 | |
Vibration resistance | DIN EN 60068-2-64 / IEC 60068-2-64 | |
Climate class | DIN EN 60068-2-38/IEC 68-2-38 | |
Bluetooth | IEEE 802.15.1 | |
Measurement accuracy | ||
Accuracy | up to ± 2 mm | |
Operating conditions | ||
Process conditions | ||
Process temperature | -40 ... 80 °C (-40 ... 176 °F) | |
Process pressure | threaded process connection relative pressure : -1 ... 3 bar (-14.5 ... 43.5 psi) absolute pressure : < 4 bar (58 psi) UNI flange process connection relative pressure : -1 ... 1 bar (-14.5 ... 14.5 psi) absolute pressure : < 2 bar (29 psi) |
|
State of aggregation | liquid | |
Dielectric constant | 4 ... 10 , e. g. concentrated acid, organic solvents, ester, aniline, alcohol, acetone, ... > 10 , e.g. conductive liquids, aqueous solutions, diluted acids and bases |
|
Ambient conditions | ||
Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) -40 ... 60 °C (-40 ... 140 °F) when using the Bluetooth connection |
|
Storage temperature | -40 ... 80 °C (-40 ... 176 °F) | |
Vibration resistance | 20 ... 2000 Hz, 1 (m/s2)2/Hz | |
Mechanical specifications | ||
Degree of protection | IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP66, NEMA 4X |
|
Connection | cable 2 x 0,75 mm2 | |
Material | sensor housing: PVDF seal: EPDM back side process connection: PVDF cable gland: PA conduit adapter: CuZn nickel-plated O-ring: EPDM counter nut: PA6.6 design ring: PBT-PC front side process connection: PVDF cable: PVC |
|
Cable | ||
Length | 5 m 10 m 20 m specified length, any length from 5 to 300 m (16 ... 980 foot) |
|
Mass | - device with 40 mm (1.5 inch) antenna with 5 m cable: 2.5 kg - device with 80 mm (3 inch) antenna with 5 m cable: 2.8 kg |
|
Dimensions | - device with 40 mm (1.5 inch) antenna: ∅75 x 140 mm - device with 80 mm (3 inch) antenna: ∅115 x 206 mm |
|
Process connection | Back side: thread ISO228 G1, ASME MNPT1 Front side: - thread ISO228 G1-1/2, ASME MNPT1-1/2 - thread ISO228 G2, ASME MNPT2 - UNI slip on flange 3 inch/DN80/80, 4 inch/DN100/100, 6 inch/DN150/150 |
|
Data for application in connection with hazardous areas | ||
EU-type examination certificate | see instruction manuals (SI) | |
Directive conformity | ||
Directive 2014/34/EU | EN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-26:2015 | |
International approvals | ||
CSA approval | see instruction manuals (SI) | |
IECEx approval | see instruction manuals (SI) | |
Certificates and approvals | ||
Telecommunications | radio license FCC | |
General information | ||
Supplementary documentation | technical information (TI) manuals, brief instructions (BA, KA) instruction manuals (SI) |
|
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. | |
Accessories | ||
Designation | see technical information (TI) |
System | Classcode |
---|---|
ECLASS 13.0 | 27200513 |
ECLASS 12.0 | 27200513 |
ECLASS 11.0 | 27200513 |
ECLASS 10.0.1 | 27200513 |
ECLASS 9.0 | 27200513 |
ECLASS 8.0 | 27200513 |
ECLASS 5.1 | 27200513 |
ETIM 9.0 | EC002995 |
ETIM 8.0 | EC002995 |
ETIM 7.0 | EC002995 |
ETIM 6.0 | EC002995 |
ETIM 5.0 | EC001447 |
UNSPSC 12.1 | 41111950 |
Product category / 产品类的 |
Product information | 语言 | 文件类型 | 文件大小 |
---|---|---|---|
TI01267O, Technical information LCR20 | ENG | 3165 KB | |
Brief Instructions | |||
EA01103O, Installation instructions LCR20 | ENG | 1847 KB | |
KA01248O, Brief instructions LCR20 | ENG | 3323 KB | |
Safety and Security Documentation | |||
Instruction manual / Betriebsanleitung | CHS | 349 KB | |
Manuals | |||
BA01578O, Manual LCR20 | ENG | 4252 KB |
Certificates | 证书号码 | 语言 | 文件类型 | 文件大小 |
---|---|---|---|---|
Canada Radio Approval | 7037A-2KL | ALL | 1256 KB | |
Canada Radio Approval | 7037A-2KT | ALL | 1256 KB | |
Canada, USA CSA Hazardous Location | CoC 80054888 cUS | ALL | 91 KB | |
Eurofins SEV IECEx Certificate of Conformity Ex ia | IECEx SEV 20.0029X | ALL | LINK | --- |
Europe Eurofins SEV ATEX Category 1/2 G ATEX Category 1 G | SEV 20 ATEX 0490X | ALL | 1865 KB | |
USA FCC Approval | IRELCR2XKT | ALL | 183 KB | |
USA FCC Approval | IRELCR2XKT | ALL | 183 KB | |
USA FCC Approval | IRELCR2XKL | ALL | 183 KB | |
USA FCC Approval | IRELCR2XKL | ALL | 186 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-4928 | ALL | 89 KB |
Device Description Files/Drivers | Release Info | 文件类型 | 文件大小 |
---|---|---|---|
DTM Collection Level Control Technology / DTM Collection Level Control Technology | 1.8.40 | ZIP | 101185 KB |
Software Tools | |||
PACTware 5.0 / PACTware 5.0 | 5.0.5.31 | ZIP | 44203 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|