Servisní linka pro průmyslové snímače
Kontaktujte zákaznický servis
Servisní linka ochrany před výbuchem
Kontaktujte zákaznický servis
Nedostupné pro prodej
Nedostupné pro prodej

Diagnostic Gateway Kit KT-MB-GT2AD.FF.IO

FieldConnex® Fieldbus
KT-MB-GT2AD.FF.IO
  • System integration kit for Advanced Diagnostics
  • PCS integration via Diagnostic Manager or device DTM
  • Simple automatic setup of Advanced Diagnostics
  • Alarm handling and integrated I/O for cabinet monitoring/control
  • For FOUNDATION Fieldbus and PROFIBUS PA
  • Installation in Zone 2

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Stáhněte si kompletní katalogový list ve formátu PDF:

English

Výňatek z katalogového listu: Technická data   KT-MB-GT2AD.FF.IO

Popis produktu
Diagnostic gateway kit with Ethernet, FF-H1 interface, I/O, for advanced diagnostics
General specifications
Design / MountingMotherboard based
Installation in hazardous areaZone 2 / Div. 2
Supply
Rated voltage19.2 ... 35 V DC SELV/PELV
Rated current210 ... 120 mA
Power dissipationmax. 4.2 W
Fieldbus connection
Number of segments4
Fieldbus typeFOUNDATION Fieldbus
Physical layer profileprofile type 114
ITK version6
Implementationresource block 1x RS
function block 4x MDI, 1x MDO, 1x MAI, 1x DI
transducer block 16x ADM TB, 1x IO TB
Firmware updateEthernet
Polaritypolarity-sensitive
Rated voltage9 ... 35 V
Rated current0 mA
Ethernet Interface
Rated voltagemax. 35 V SELV/PELV
Port100 BASE-TX
ProtocolTCP/IP and UDP/IP
ServicesICMP , DHCP , AutoIP , HTTP
Connection typeRJ-45 socket, 8-pin
Transfer rate100 MBit/s
Diagnostic Bus
Connectiononly for the connection to protected circuits
Rated voltagemax. 35 V
Number of Diagnostic Bus Channels2
Number of Diagnostic Modules/Channel31 Using Ethernet Interface , 8 Using Fieldbus Interface
Terminationintegrated
Cable length/Channel30 m
Indicators/operating means
LED ERRred: Hardware fault
LED PWRgreen: Power on
Fault signalbuzzer on
LINK/ACTyellow
CH1, CH2yellow: diagnostic bus activity
Inputs
Input I, II
Input typeselectable: Frequency input , NAMUR/mechanical contact
Frequency
Connectiononly passive load
Rated voltagemax. 35 V
Input frequency0.3 Hz to 1 kHz
Pulse durationmin. 50 µs
Accuracy± 1 %
Cable lengthmax. 30 m
Line fault detectionlead breakage , short-circuit
NAMUR
Sensor typeNAMUR sensor according to IEC/EN 60947-5-6
Connectiononly passive load
Rated voltagemax. 35 V
Switching frequency10 Hz
Cable lengthmax. 30 m
Line fault detectionlead breakage , short circuit
Input III, IV
Input typeNAMUR/mechanical contact
NAMUR
Sensor typeNAMUR sensor according to IEC/EN 60947-5-6
Connectiononly passive load
Rated voltagemax. 35 V
Switching frequency10 Hz
Cable lengthmax. 30 m
Line fault detectionlead breakage , short circuit
Input V
Input typeselectable: diagnostic bus CH 1 alarm input , NAMUR/mechanical contact
Alarm Input
Connectiononly passive load
Rated voltagemax. 35 V
Cable lengthmax. 30 m
Line fault detectionlead breakage , short circuit
NAMUR
Sensor typeNAMUR sensor according to IEC/EN 60947-5-6
Connectiononly passive load
Rated voltagemax. 35 V
Switching frequency10 Hz
Cable lengthmax. 30 m
Line fault detectionlead breakage , short circuit
Input VI
Input typeselectable: diagnostic bus CH 2 alarm input , NAMUR/mechanical contact
Alarm Input
Connectiononly passive load
Rated voltagemax. 35 V
Cable lengthmax. 30 m
Line fault detectionlead breakage , short-circuit
NAMUR
Sensor typeNAMUR sensor according to IEC/EN 60947-5-6
Connectiononly passive load
Rated voltagemax. 35 V
Switching frequency10 Hz
Cable lengthmax. 30 m
Line fault detectionlead breakage , short circuit
Input VII, VIII
Input typeselectable: Pt100 4-wire temperature input , NAMUR/mechanical contact
Temperature
Connectiononly passive load
Rated voltagemax. 35 V
Measuring range-50 ... 90 °C (-58 ... 194 °F)
Accuracy1 K
Measuring current1 mA
Lead resistance4.2 Ω per line
Cable lengthmax. 30 m
Line fault detectionlead breakage , short-circuit
NAMUR
Sensor typeNAMUR sensor according to IEC/EN 60947-5-6
Connectiononly passive load
Rated voltagemax. 35 V
Switching frequency10 Hz
Cable lengthmax. 30 m
Line fault detectionlead breakage , short circuit
Humidity
Measuring range0 ... 95 % RH
Accuracy2 % RH
Resolution0.04 %
Outputs
Output I
Output typeselectable: diagnostic bus CH 1 , relay , NO contact
Contact loading250 V AC/ 6 A resistive load
Mechanical life1 x 105 switching cycles
Response timeturn-on time 7 ms , turn-off time 3 ms
Switching frequency6 min-1 full load, 1200 min-1 without load
Output II
Output typeselectable: diagnostic bus CH 2 , relay , NO contact
Contact loading250 V AC/ 6 A resistive load
Mechanical life1 x 105 switching cycles
Response timeturn-on time 7 ms , turn-off time 3 ms
Switching frequency6 min-1 full load, 1200 min-1 without load
Output III
Output typeselectable: common alarm , volt-free contact , NC contact
Connectiononly for the connection to protected circuits
Voltage50 V DC
Currentmax. 1 A
Output IV
Output typecommon alarm , buzzer
Galvanic isolation
All circuits/FEfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Output I, II/other circuitsfunctional insulation acc. to IEC 62103, rated insulation voltage 250 Veff
Ethernet/Supplyfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Ethernet/other circuitsfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Fieldbus/other circuitsfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Diagnostic Bus/other circuitsfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Low voltage
Directive 73/23/EECEN 61010-1:2010
Standard conformity
Galvanic isolationIEC 62103
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Climatic conditionsDIN IEC 721
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
EthernetIEEE 802.3
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F) hazardous area
-40 ... 70 °C (-40 ... 158 °F) safe area horizontal DIN rail mounting
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity< 95 % non-condensing
Shock resistance5 g 11 ms
Vibration resistance1 g , 10 ... 150 Hz
Pollution degreemax. 2, according to IEC 60664
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Connection typescrew terminal , pluggable
Housing materialPolycarbonate
Degree of protectionIP20
Mass500 g
Dimensions
Heightsee dimensions
Widthsee dimensions
Depthsee dimensions
MountingDIN rail mounting
Data for application in connection with hazardous areas
FOUNDATION Fieldbus
ConnectionFor connection to circuits with safe limited voltage according to IEC 60079-11:2011, type of protection "ic"
Voltage Uimax. 35 V
CertificateTÜV 14 ATEX 115980 X
MarkingMotherboard MB-FB-GT.AD.FF.IO Ex-Hexagon II 3 G Ex nA nC IIC T4 Gc , Gateway Ex-Hexagon II 3 G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
IECEx approvalIECEx TUN 14.0003X
Approved forMotherboard Ex nA nC IIC T4 Gc , Gateway Ex nA IIC T4 Gc
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027242692
ECLASS 12.027242692
ECLASS 11.027242692
ECLASS 10.0.127242692
ECLASS 9.027242692
ECLASS 8.027242692
ECLASS 5.127242692
ETIM 9.0EC001604
ETIM 8.0EC001604
ETIM 7.0EC001604
ETIM 6.0EC001604
ETIM 5.0EC001604
UNSPSC 12.139121008

Technologie Ethernet-APL umožňuje nepřetržitou komunikaci napříč všemi hierarchickými úrovněmi. Další informace o průkopnické technologii…

Informační služba RSS pro aktualizace systém PANOS

Buďte informováni o vydání nové aktualizace softwaruPANOS, operačního systému pro přepínače Ethernet-APL: Díky našemu informačnímu kanálu RSS obdržíte ihned po vydání aktualizace e-mailové upozornění do své e-mailové schránky.

Od rozhodování a plánování přes instalaci a uvedení do proozu až po provoz a údržbu: Objevte, jak co nejlépe využít svou sběrnicovou infrastrukturu…

undefined

We value your privacy!

We and our partners are using technologies like cookies and process personal data like the IP-address or browser information in order to personalize the advertising that you see. This helps us to show you more relevant ads and improves your internet experience. We also use it in order to measure results or align our website content. Because we value your privacy, we are herewith asking for your permission to use these technologies. You can always change/withdraw your consent later by clicking on the settings button on the left lower corner of the page.

Deny all cookies

We value your privacy!

Please select the group of cookies and scripts, that you consent to.

Functional
These cookies are necessary so that you can navigate through the pages and use essential functions (e.g. login).
Analytics
We use these cookies and scripts to measure the visits and clicks on our website in order to constantly improve it.
Marketing
These cookies and similar technologies are used to provide you with personalized and therefore relevant advertising content.