Fire protection retroreflective sensor MLV12-54-2563/49/124

MLV12-54-2563/49/124
  • Small fire protection photoelectric sensor for safety devices on fire barriers
  • Approval in accordance with VdS Test Report FSA and externally monitored manufacture (Ü Symbol)
  • High protection against contact
  • Not sensitive to ambient light, even with switched energy saving lamps

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

A teljes adatlap letöltése PDF formátumban:


Adatlap kivonata: Műszaki adatok  MLV12-54-2563/49/124

Termék leírása
Small fire protection photoelectric sensor
General specifications
Effective detection range0 ... 2.1 m (with H60 reflector)
Reflector distance0.2 ... 2.1 m
Reference targetH60 reflector
Light sourceLED 645 nm
Light typemodulated visible red light
Diameter of the light spotapprox. 70 mm
Opening angle1.5 °
Ambient light limit50000 Lux
Indicators/operating means
Operation indicatorLED green, flashes in case of short-circuit
Function indicator2 LEDs yellow, light up when light beam is free, flash when falling short of the operating reserve, are off when light beam is interrupted
Control elementsrotary switch for light/dark
Electrical specifications
Operating voltage10 ... 30 V DC
Ripplemax. 10 %
No-load supply currentmax. 40 mA
Protection classII, rated voltage ≤ 300 V AC with pollution degree 1-2 according to IEC 60664-1
Output
Switching typelight/dark on switchable
Signal output1 NPN and 1 PNP output, direct switching, short-circuit protected, reverse polarity protected, open collector
Switching voltagemax. 30 V DC
Switching currentmax. 0.2 A
Voltage drop≤ 2.5 V DC
Switching frequency≤ 40 Hz
Response time10 ms
Conformity
Product standardEN 60947-5-2
Standard conformity
StandardsEN 60947-5-2
smoke insensitive up to 2 dB/m ( EN 54-12 )
Approvals and certificates
UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure
CCC approvalCCC approval / marking not required for products rated ≤36 V
ApprovalsVdS/DIBt certificate of compliance No. 25020 , approval number Z-6.510-2295
Ambient conditions
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 75 °C (-40 ... 167 °F)
Relative humidity30% ... 85%   non-condensing ; Non-icing
Mechanical specifications
Degree of protectionIP67
Connection5-pin M12 x 1 connector with metal thread, 90° rotatable
Material
HousingFrame: nickel plated, die cast zinc,
Laterals: glass-fiber reinforced plastic PC
Optical facePlastic pane
Mass60 g
Dimensions
Height49 mm
Width41.5 mm
Depth15 mm

Classifications

SystemClasscode
ECLASS 13.027270902
ECLASS 12.027270902
ECLASS 11.027270902
ECLASS 10.0.127270902
ECLASS 9.027270902
ECLASS 8.027270902
ECLASS 5.127270902
ETIM 9.0EC002717
ETIM 8.0EC002717
ETIM 7.0EC002717
ETIM 6.0EC002717
ETIM 5.0EC002717
UNSPSC 12.139121528

Details: MLV12-54-2563/49/124

Function

It is essential that fire is not allowed to spread in buildings should it break out. Fire protection regulations therefore prescribe fire barriers. These include fire doors, industrial fire doors and fire dampers, which are generally kept closed at all times. In areas where doors are left open, such as heavily traveled passageways and corridors, a self-closing mechanism must be automatically triggered in case of fire. However, the door must not close when persons or objects are in the closing area. Legislation consequently requires monitoring with appropriate safety devices. The technical challenge is to ignore the smoke and at the same time reliably detect objects in it. These certified photoelectric sensors fulfill this function.

Informative Literature: MLV12-54-2563/49/124

Nyelvválasztás:
We are sorry, there are no documents for your language selection. Please select another language.

Product Documentation: MLV12-54-2563/49/124

Nyelvválasztás:
Brief InstructionsNyelvFájltípusFájlméret
Instruction leaflet / BeipackzettelALLPDF368 KB

Design / Simulation: MLV12-54-2563/49/124

Nyelvválasztás:
CADNyelvFájltípusFájlméret
CAD 3-D / CAD 3-DALLSTP200 KB
CAD 3-D additional / CAD 3-D additionalALLSTP200 KB
CAD Portal / CAD PortalALLLINK---

Approvals: MLV12-54-2563/49/124

Nyelvválasztás:
CertificatesTanúsítvány sz.NyelvFájltípusFájlméret
Canada USA UL Ordinary LocationUL-US-L87056-11-41301991-3 / UL-CA-L87056-31-41301991-3ALLPDF1806 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-0916CALLPDF308 KB

Kapcsolódó termékek: MLV12-54-2563/49/124

Accessories

Female cordset single-ended M12 straight A-coded, 5-pin, PUR cable greyfa

Female connector M12 straight A-coded 5-pin, for cable diameter 6 - 8 mm, field-attachablefa

Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable black, UL approved, drag chain suitable, torsion resistantfa
Reflector with mounting holesfa
Mounting bracket for series MLV12 sensorsfa
Mounting bracket for series MLV12 sensorsfa
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa
dove tail mounting clampfa
dove tail mounting clampfa
dove tail mounting clampfa
R10x és R20x sorozatú fotoelektromos érzékelők

Most először kapható összehangolt, fotoelektromos működési elvek és innovatív technológiák felhasználásával készült, egységes házakkal szerelt portfólió. A felhasználók az egységes működési koncepció minden előnyét kihasználhatják a teljes választékban. Fedezze fel az R100, R101, R103, R200 és R201 sorozatot...

ML100 fotoelektromos érzékelő

Legyen szó üvegről, napelemekről vagy nyomtatott áramköri lapokról: Az ML100 sorozat fotoelektromos érzékelőit pontosan úgy tervezték, hogy megfeleljenek a különböző összetett érzékelési feladatok követelményeinek. Tudjon meg többet a portfólióról...