Supply |
Connection | backplane bus |
Nominal voltage | 12 V DC , only in connection with the power supplies FB92** |
Power dissipation | 4.24 W |
Power consumption | 4.24 W |
Fieldbus connection |
Fieldbus type | PROFINET |
Ethernet Interface |
Connection type | M12 , via front connector |
Transfer rate | 10BASE-T, 100BASE-TX 100 MBit/s |
Station connection | directly to PCS or PLC or via hubs or switches |
Cable type | SFTP in accordance with ISO/IEC 11801 for Cat 5e or better |
Bus length | max. 100 m per link |
Addressing | DHCP or fixed IP address |
Ethernet address | IP V4 address (factory standard setting: 0.0.0.0, auto IP, DHCP) |
Supported I/O modules | FB1x01*…FB1x03*, FB1x08*, FB1x09*, FB2x01*...FB2x17*, FB3x01*…FB3x06*, FB4x01*, FB4x02*, FB4x04*…FB4x06*, FB5x01*, FB5x02*, FB5x04*…FB5x06*, FB6x01*, FB6x05*, FB6x06*, FB6x08*, FB6x10*…FB6x17*, FB7x04 |
PROFINET conformance class | CC B |
Internal bus |
Connection | backplane bus |
Galvanic isolation |
Ethernet/other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 32 V DC (SELV/PELV) |
RS 485 interface/other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 V DC |
Insulation voltage | 1500 V AC acc. to IEEE 802.3u |
Electrical isolation |
Power supply, internal bus/other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 30 V DC |
Indicators/settings |
LED indication | See below in the front view |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 |
Conformity |
Electromagnetic compatibility | NE 21 |
Degree of protection | IEC 60529 |
Environmental test | EN 60068-2-14 |
Shock resistance | EN 60068-2-27 |
Vibration resistance | EN 60068-2-6 |
Damaging gas | EN 60068-2-42 |
Relative humidity | EN 60068-2-78 |
Ambient conditions |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Relative humidity | 95 % non-condensing |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications |
Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
Connection | via backplane |
Mass | approx. 965 g |
Dimensions | 57 x 107 x 151 mm |
Data for application in connection with hazardous areas |
EU-type examination certificate | PTB 19 ATEX 2007 U |
| Marking | II 2G Ex db eb ib q IIC Gb |
Directive conformity | |
| Directive 2014/34/EU | EN IEC 60079-0:2018 EN 60079-1:2014 EN 60079-5:2015 EN 60079-7:2015 EN 60079-11:2012 |
International approvals |
ATEX approval | |
| ATEX certificate | PTB 19 ATEX 2007 U |
IECEx approval | |
| IECEx certificate | IECEx PTB 19.0025U |
| IECEx marking | Ex db eb ib q IIC Gb |
General information |
System information | The module may be installed only in the associated backplanes FB9262BP*.2 in Zone 1, Zone 2, or outside the hazardous area. Observe the corresponding EC-type examination certificate. |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |