Servizio assistenza Sensori Industriali
Telefono: +39 039 69599 1
Fax.: +39 039 69599 30
Servizio assistenza Protezione contro le esplosioni
Telefono ++39 039 62921
Fax ++39 039 6292 390

Switch Amplifier S1SD-1DI-1R

S1SD-1DI-1R
  • 1-channel signal conditioner
  • 24 V DC supply
  • Input for 2- or 3-wire sensors or AC/DC voltage sources
  • Relay contact output
  • Timer function
  • Configurable by DIP switches
  • Connection via screw terminals

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Scarica il Datasheet completo in formato PDF:


Estratto del Datasheet: Dati tecnici del  S1SD-1DI-1R

General specifications
Signal typeDigital Input
Supply
ConnectionPower Bus or terminals 1-, 2+
Rated voltage16.8 ... 31.2 V DC
Power dissipation0.6 W
Power consumption1.1 W
Input
Connection sidefield side
NAMUR sensor
Type2-wire
Connectionterminals 5+, 6
Signalacc. to EN 60947-5-6 (NAMUR)
Sensor supply8 V
Open-circuit< 0.1 mA
Switching point1.2 ... 2.1 mA
Short-circuit> 6 mA
Input impedance1 kΩ
Mechanical contact
Type2-wire
Connectionterminals 5+, 6
Sensor supply15 V
External supply≤ 32 V
Switching point8 ... 10 V / 1.2 ... 2.1 mA
Input impedance4 kΩ
SN sensor
Type2-wire
Connectionterminals 5+, 6
Sensor supply8 V
Open-circuit< 0.1 mA
Switching point1.2 ... 2.1 mA
Short-circuit> 6 mA
Input impedance1 kΩ
2-wire DC sensor
Type2-wire
Connectionterminals 5+, 6
Signalacc. to EN 60947-5-2
Sensor supply16 V / 25 mA , short-circuit protected
External supply≤ 32 V
Switching point2 ... 5 mA
Input impedance1 kΩ
S0 sensor
Type2-wire
Connectionterminals 5+, 6
Signalacc. to EN 62053-31 , Type B
Sensor supply15 V
Switching point0.15 ... 2 mA
Input impedance4 kΩ
NPN sensor
Type3-wire
Connectionterminals 5+, 6, 7-
Signalacc. to EN 60947-5-2
Sensor supply16 V / 25 mA , short-circuit protected
External supply≤ 32 V
Switching point3 ... 5 V
Input impedance4 kΩ
PNP sensor
Type3-wire
Connectionterminals 5+, 6, 7-
Signalacc. to EN 60947-5-2
Sensor supply16 V / 25 mA , short-circuit protected
External supply≤ 32 V
Switching point8 ... 10 V
Input impedance4 kΩ
AC/DC voltage source
Connectionterminals 7, 8
Signal24 V AC/DC
Switching point10 ... 15 V
Input impedance> 680 kΩ
AC/DC voltage source
Connectionterminals 7, 8
Signal115 V AC/DC
Switching point40 ... 60 V
Input impedance> 680 kΩ
AC/DC voltage source
Connectionterminals 7, 8
Signal230 V AC/DC
Switching point80 ... 115 V
Input impedance> 680 kΩ
Output
Connection sidecontrol side
Connectionterminals 3, 4:
Outputsignal, relay
Contact loading253 V AC/2 A/cos φ > 0.7; 126.5 V AC/2 A/cos φ > 0.7; 30 V DC/2 A resistive load
Minimum switch current2 mA / 24 V DC
Energized/De-energized delay≤ 20 ms / ≤ 20 ms
Mechanical life107 switching cycles
Transfer characteristics
Switching frequency≤ 10 Hz
Galvanic isolation
Output/power supplysafe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min
Input/Other circuitssafe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min
Indicators/settings
Control elementsDIP switch
Configurationvia DIP switches
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EUEN 61010-1:2010
Conformity
Degree of protectionIEC 60529:2001
Protection against electrical shockEN 61010-1:2010
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Core cross section0.5 ... 2.5 mm2 (20 ... 14 AWG)
Massapprox. 60 g
Dimensions6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1
Height97 mm
Width6.2 mm
Depth107 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210121
ECLASS 12.027210121
ECLASS 11.027210121
ECLASS 10.0.127210121
ECLASS 9.027210121
ECLASS 8.027210121
ECLASS 5.127210121
ETIM 9.0EC001485
ETIM 8.0EC001485
ETIM 7.0EC001485
ETIM 6.0EC001485
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: S1SD-1DI-1R

Informative Literature: S1SD-1DI-1R

Language Selection:
LiteratureLinguaFile tipoDimensioni
Application Report - Sand Trap and Preliminary Sedimentation StageENGPDF448 KB
Product Overview SC-SystemENGPDF456 KB
Tender text
Tender textENGD8111 KB

Product Documentation: S1SD-1DI-1R

Language Selection:
Safety and Security DocumentationLinguaFile tipoDimensioni
Manuale di istruzioniITAPDF119 KB
Manuals
System ManualENGPDF2706 KB

Design / Simulation: S1SD-1DI-1R

Language Selection:
CADLinguaFile tipoDimensioni
CAD 3-D / CAD 3-DALLSTP4814 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ82 KB
EPLAN macros SC-System devices (EDZ) / EPLAN-Makros SC-System-Geräte (EDZ)ALLZIP4082 KB

Approvals: S1SD-1DI-1R

Language Selection:
Declaration of ConformityCertificato NumeroLinguaFile tipoDimensioni
EU Declaration of Conformity (P+F)TDOC-2695CITAITAPDF169 KB

Prodotti associati : S1SD-1DI-1R

Matching System Components
Interface for Power Bus, Supply current 3 A, LED status indication, Connection via screw terminalspa
Bus carrier with bus PCB for 35 mm DIN mounting rail, height 7.5 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 250 mm (9.84 inch), simple to customize to application space, Eliminates daisy-chainspa
Bus carrier with bus PCB for 35 mm DIN mounting rail, height 15 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 250 mm (9.84 inch), simple to customize to application space, Eliminates daisy-chainspa
Cover for DIN mounting rail, Suitable for Power Bus, Standard length 250 mm (9.84 inch), simple to customize to application space, Packaging unit: 5 piecespa
Fixing of the bus carrier with bus PCB in the DIN mounting rail, Termination of DIN mounting rail, Suitable for Power Bus, Packaging unit: 5 pieces left, 5 pieces rightpa