General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Linearity error | ± 0.025 ° | |
Pulse count | max. 5000 | |
Functional safety related parameters | ||
MTTFd | 435 a | |
Mission Time (TM) | 10 a | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 4.75 ... 30 V DC | |
No-load supply current | max. 50 mA | |
Output | ||
Output type | push-pull or RS422 (universal output driver, output level depending on input voltage) | |
Load current | max. per channel 40 mA , short-circuit protected, reverse polarity protected | |
Output frequency | max. 400 kHz | |
Rise time | 300 ns | |
Phase position A to B | ||
Pulse counts < 3600 | 90 ° ± 9 ° electrical | |
Pulse counts ≥ 3600 | 90 ° ± 25 ° electrical | |
Duty cycle | 1/2 ± 10 % | |
Connection | ||
Connector | M12 connector, 8-pin M12 connector, 5 pin M23 connector, 12-pin , clockwise rotation M23 connector, 12-pin , counter clockwise rotation |
|
Cable | ∅6 mm, 4 x 2 x 0.14 mm2 | |
Terminal compartment | Cable duct for cable diameter ∅4.0 mm ... 9.5 mm | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65, IP66, IP67 | |
Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
Salt spray test | DIN EN 60068-2-52 , 672 h | |
Emitted interference | EN IEC 61000-6-4:2019 | |
Noise immunity | EN IEC 61000-6-2:2019 | |
Shock resistance | DIN EN 60068-2-27, 200 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 20 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | E223176 , cULus Listed, General Purpose, Class 2 Power Source, Type 1 enclosure , if UL marking is marked on the product. For use in NFPA 79 Applications only. adapters providing field wiring on request | |
Maximum permissible ambient temperature | max. 80 °C (max. 176 °F) | |
Ambient conditions | ||
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) , fixed cable -5 ... 85 °C (23 ... 185 °F) , movable cable |
|
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Material | ||
Housing | powder coated aluminum | |
Flange | aluminium, salt water resitant | |
Shaft | Stainless steel 1.4305 / AISI 303 | |
Mass | < 1100 g without cable | |
Rotational speed | max. 3000 min -1 for IP66/IP67 |
|
Starting torque | ≤ 0.25 Nm for IP66/IP67 |
|
Shaft insulation | max. 2.5 kV (for dielectric strength version) | |
Shaft load | ||
Axial | ≤ 100 N | |
Radial | ≤ 300 N | |
Dimensions | ||
Length | 84.5 mm | |
Diameter | 93 mm |
System | Classcode |
---|---|
ECLASS 13.0 | 27270501 |
ECLASS 12.0 | 27270501 |
ECLASS 11.0 | 27270501 |
ECLASS 10.0.1 | 27270501 |
ECLASS 9.0 | 27270501 |
ECLASS 8.0 | 27270501 |
ECLASS 5.1 | 27270501 |
ETIM 9.0 | EC001486 |
ETIM 8.0 | EC001486 |
ETIM 7.0 | EC001486 |
ETIM 6.0 | EC001486 |
ETIM 5.0 | EC001486 |
UNSPSC 12.1 | 39121527 |
Brief Instructions | Lingua | File tipo | Dimensioni |
---|---|---|---|
Instruction leaflet / Beipackzettel | ALL | 288 KB |
CAD | Lingua | File tipo | Dimensioni |
---|---|---|---|
CAD Portal / CAD Portal | ALL | LINK | --- |
Certificates | Certificato Numero | Lingua | File tipo | Dimensioni |
---|---|---|---|---|
Canada, USA UL General Purpose | CoC UL-US-L223176-11-02907102-1 / UL-CA-L223176-31-02907102-1 | ALL | 546 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|