Línea de servicio de Sensores Industriales
Teléfono: +34 94 453 50 20
Fax: +34 94 453 51 80
Atención al cliente para protección contra explosiones
Teléfono: +34 94 453 50 20
Fax: +34 94 453 51 80

No disponible para compra

Este producto ha sido sustituido.Ir al producto de sustitución VAZ-2E2A-G20-ZPA1
No disponible para compra
No disponible para compra

Stand-alone connecting module VAZ-2E2A-G20-ZPA1

VAZ-2E2A-G20-ZPA1
  • Inputs for 3-wire sensors
  • Outputs for DC roller motors (drum motors)
  • Interface for coupling with adjacent zones
  • Connection of motors and sensors via M8 connectors
  • Operating mode, motor speed and start/stop ramp can be configured using the rotary switch
  • Supply of 24 VDC, connection via insulation piercing technology with gold-plated contact pins
  • Function indicator for power supply, inputs and outputs, and zone coupling

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Descargue la hoja de datos completa en PDF:


Extracto de la hoja de datos: Información técnica del  VAZ-2E2A-G20-ZPA1

Descripción del producto
G20 motor control module with an integrated logic function for Interroll EC310, Interoll EC5000 24V AI, Rulmeca BL3, Itoh Denki PM500XK, Itoh Denki PM500XC
General specifications
UL File NumberE223772 "For use in NFPA 79 Applications only"
Compatible roller motorsInterroll EC310, Interroll EC5000 24V AI (20W / 35W / 50W), Rulmeca BL3, Itoh Denki PM500XK, Itoh Denki PM500XC
Indicators/operating means
SwitchS1: motor speed; rotary switch, 10 positions
S2: direction of rotation and start/stop ramp; rotary switch, 10 positions
S3: operating mode, rotary switch, 10 positions
LED ERRMotor fault; 2 yellow LEDs
yellow: motor error
flashing yellow: motor protection unit defective
LED PWRSupply voltage UPWR; green LED
LED INswitching state (input); 2 LED yellow
LED MOTMotor active; 2 yellow LEDs
LED XINZone coupling input active; 2 yellow LEDs
LED XOUTZone coupling output active; 2 yellow LEDs
Electrical specifications
Rated operating voltage18 V ... 30 V DC PELV (via UPWR)
Rated operating current≤ 30 mA (Closed-circuit current) max. 10 A (<2 s)
Surge protectionUPWR: overvoltage category II, securely isolated power supply (PELV)
Interface 1
Interface typeInterface for coupling zones with one input and one output for control signals X1
Physical 4-pin M12 socket
Electronic output: PNP, overload and short-circuit proof (X1OUT)
Input: PNP, galvanically isolated, potential-free (X1IN)
Load currentInput: ≤ 8 mA (internally limited)
Output: 10 mA
VoltageInput: max. 30 V DC
Output (via UPWR): ≥ (UPWR - 2 V)
Switching pointin accordance with DIN EN 61131-2 (type 1)
0 (undamped): ≤ 0.5 mA
1 (damped): ≥ 2 mA
Interface 2
Interface typeInterface for coupling zones with one input and one output for control signals X2
Physical M12 connector, 4-pin
Electronic output: PNP, overload and short-circuit proof (X2OUT)
Input: PNP, galvanically isolated, potential-free (X2IN)
Load currentInput: ≤ 8 mA (internally limited)
Output: 10 mA
VoltageInput: max. 30 V DC
Output (via UPWR): ≥ (UPWR - 2 V)
Switching pointin accordance with DIN EN 61131-2 (type 1)
0 (undamped): ≤ 0.5 mA
1 (damped): ≥ 2 mA
Input
Number/Type2 Inputs for 3-wire sensors (PNP), DC
Supplyvia UPWR
Current loading capacity500 mA , overload and short-circuit protected
Input current≤ 8 mA (limited internally)
Switching pointaccording to DIN EN 61131-2
0 (undamped) ≤ 0.5 mA
1 (damped) ≥ 2.0 mA
Input filter10 ms
Output
Number/Type2 outputs for DC roller motors (MOT1, MOT2)
Supplyvia UPWR
Current3.5 A continuous current , 5 A (<2 s) , max. 7.5 A (<0,3 s) per motor
Overload protectionfuse , I2t = 53.7 A2s
Velocity signal1.4 … 13 V at no-load
Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ
Control using rotary switch S1
Rotation direction signallow: high impedance
high; ≥ (UPWR - 1.0 V) in no-load operation
Ri = 5.6 kΩ, RLOAD ≥ 5 kΩ
Control using rotary switch S2
Motor faultNPN digital input, U0 = 14 V, Ri = 34 kΩ
0 (no error) ≥ 125 µA
1 (error) ≤ 25 µA
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2006
Standard conformity
Degree of protectionEN 60529:2000
InputEN 61131-2:2007
Emitted interferenceEN 61000-6-4:2007
Noise immunityEN 61000-6-2:2005 , EN 61326-1:2006
Ambient conditions
Ambient temperature-30 ... 60 °C (-22 ... 140 °F)
Storage temperature-30 ... 85 °C (-22 ... 185 °F)
Relative humidity85 % non-condensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Pollution degree2
Mechanical specifications
Degree of protectionIP65 in accordance with EN 60529 (not certified by UL)
ConnectionPWR: insulation piercing technology
Black flat cable
Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104
Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded)
Matching connector: LM004-Gx1-A or similar
Outputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded)
Matching connector: NM005-Sx1-B or similar
Zone coupling: M12 round plug connector in accordance with EN 61076-2-101
X1: M12, 4-pin, bushing contacts, screw-locking, A-coded
Female connector: M12, 4-pin, connector contacts, screw-locking, A-coded
X2: M12, 4-pin, connector contacts, screw-locking, A-coded
Female connector: M12, 4-pin, bushing contacts, screw-locking, A-coded
Mass310 g
Dimensions
Height27.5 mm
Width131.5 mm
Length54 mm
Mounting2 clips with ∅ 8 mm drill hole
Cable length1 m (inputs/outputs) , 1.5 m (zone coupling), max. 30 m
NoteThe flat cable routing is designed for 100 actuation cycles

Classifications

SystemClasscode
ECLASS 13.027242604
ECLASS 12.027242604
ECLASS 11.027242604
ECLASS 10.0.127242604
ECLASS 9.027242604
ECLASS 8.027242604
ECLASS 5.127242604
ETIM 9.0EC001599
ETIM 8.0EC001599
ETIM 7.0EC001599
ETIM 6.0EC001599
ETIM 5.0EC001599
UNSPSC 12.139121535

Details: VAZ-2E2A-G20-ZPA1

Función

El módulo de control del motor es un módulo de campo con dos entradas de sensor y dos salidas electrónicas para controlar rodillos accionados por motor de CC. El módulo está optimizado para su uso con los modelos Interroll EC310 y Rulmeca BL3. El módulo puede controlar dos zonas consecutivas de una sección de acumulación de cinta transportadora. Una zona se compone de un motor de rodillos y un sensor de zona, por ejemplo, en el caso de una barrera óptica de seguridad. Ambos controladores de zona están unidos lógicamente dentro del módulo. Es posible desactivar el segundo controlador de zona dentro del módulo.

Hay dos interfaces disponibles para acoplamiento con las zonas vecinas de la cinta transportadora. Cada una de las interfaces proporciona una entrada de señal y una salida de señal. Las interfaces se pueden conectar directamente a varios SPS-IO de 24 V.

La carcasa compacta se puede instalar directamente en los perfiles de soporte o en las canaletas. La fuente de alimentación U AUX se conecta por tecnología de perforación de aislamiento mediante un cable plano AS-Interface. La guía giratoria del cable plano se bloquea utilizando una pestaña de acoplamiento sin necesidad de herramientas.

Las entradas de sensores y las salidas de motores se conectan mediante salidas de cable con conectores macho M8 redondos. Se proporcionan salidas para cable con conectores de enchufe redondo M12 de 4 pines para el acoplamiento de zona.

El suministro de corriente a las entradas y los motores se realiza mediante la alimentación U AUX.

Los LED IN muestran el estado de conmutación actual de las entradas de sensor. Los LED MOT indican el estado de funcionamiento de los motores. Los LED ERR muestran cuándo se establece el ruido mediante un motor y un fusible defectuoso de la alimentación del motor. Los LED XIN y XOUT indican el estado de las señales de acoplamiento de zona.

El módulo está configurado mediante tres interruptores giratorios en la parte posterior del módulo. Hay disponibles 10 velocidades de motor predefinidas. Para ambas zonas, se puede ajustar el sentido de giro y la dirección de transporte. Se puede elegir entre cinco rampas de arranque/parada predefinidas. Se puede ajustar el modo de funcionamiento del módulo. En el manual de este módulo se puede encontrar una descripción detallada de los distintos modos de funcionamiento.

Informative Literature: VAZ-2E2A-G20-ZPA1

Seleccionar idioma:
LiteratureIdiomaTipo de archivoTamaño
Product Information - G20 ZPA Motor Control ModuleSPAPDF1232 KB

Product Documentation: VAZ-2E2A-G20-ZPA1

Seleccionar idioma:
Brief InstructionsIdiomaTipo de archivoTamaño
Instruction leaflet / BeipackzettelALLPDF157 KB
Manuals
ManualENGPDF1697 KB

Design / Simulation: VAZ-2E2A-G20-ZPA1

Seleccionar idioma:
CADIdiomaTipo de archivoTamaño
CAD 3-D / CAD 3-DALLSTP1738 KB
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZALLEDZ477 KB

Approvals: VAZ-2E2A-G20-ZPA1

Seleccionar idioma:
CertificatesNúmero de CertificadoIdiomaTipo de archivoTamaño
Canada, USA UL2019-2-25, 2019-07-29 (A1/C0), 2020-10-21 (A2/C0); 2024-08-28 (A3/C0)-E223772ALLPDF523 KB
US CA ULE223772ALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4085AALLPDF215 KB

Software: VAZ-2E2A-G20-ZPA1

Seleccionar idioma:
Software ToolsLiberar InfoTipo de archivoTamaño
Interactive animation software of function logic for different operating modes / Interaktive Animationssoftware zur Funktionslogik der verschiedenen Betriebsarten2019-01ZIP138977 KB

Productos asociados: VAZ-2E2A-G20-ZPA1

Accessories
Adapter cable M12 socket straight to M12 socket straight A-coded, 4-pin crossed, PUR cable black, UL approved, drag chain suitable, torsion resistantfa
Adapter cable M12 plug straight to M12 plug straight A-coded, 4-pin crossed, PUR cable black, UL approved, drag chain suitable, torsion resistantfa
Diagnostic adapter for G20 ZPA motor control modulefa