Serviceline Industrial Sensors
Serviceline Explosion Protection

RFID Reader for Zone 2/22 RFID20-*

RFID20-*
  • Flexible RFID (125 kHz and 13.56 MHz) reader with NFC capabilities
  • Flush mountable for easy integration in VisuNet Systems
  • Compatible with LogOnPlus software
  • Provides acces to all standard USB operating modes as HID, USB-CCID und USB CDC

请注意:所有以Pepperl + Fuchs GmbH或Pepperl + Fuchs AG名义发行的产品相关文件,例如证书,合格声明等,同样适用于Pepperl + Fuchs SE。

下载PDF版完整参数表:


技术参数节选  RFID20-*

产品阐述
RFID Reader/Writer for LF, HF, NFC
General specifications
TypeRFID Reader/Writer for LF, HF, NFC
Operating distanceLF and HF: Up to 76 mm / 3 inch, depending on environment and transponder
Supply
Power supply4.3 V - 5.5 V via USB; via generic interface (X2) 3.3 V ± 5% Limited power source according to the safety norms listed in the respective declaration of conformity, short-circuit current < 8 A
Indicators/operating means
IndicatorsLED green: power on
LED red flashing beeper/buzzer: read/write attempt performed
Electrical specifications
Operation frequency125 kHz (LF) / 13.56 MHz (HF)
Interface
Interface typeUSB
Directive conformity
Explosion protection
Directive 2014/34/EUEN IEC 60079-0:2018
EN IEC 60079-7:2015+A1:2018
EN IEC 60079-31:2024
Radio and telecommunication terminal equipment
Directive 2014/53/EURFID20-A-*NF-****-N**:
EN 300 330 V2.1.1
EN 301 489-1 V1.9.2
EN 62368-1:2014+AC:2015-05+AC:2015-11
EN 50364:2010
EN 62479:2010
EN 55032:2015
 
Additional standards:
EN 301 489-1 V2.1 .1
EN 301 489-3 V2.1 .1
EN 62311:2008EN 62369-1:2009
 
RFID20-B-*NF-****-N**:
EN 300 330 V2.1.1
EN 301 489-1 V1.9.2
EN 62368-1:2014+AC:2015-05+AC:2015-11
EN 50364:2010
EN 62479:2010
EN 55032:2015
 
Additional standards:
EN 301 489-1 V2.2.3
EN 301 489-3 V2.1 .1
EN 62369-1:2009
EN 62311:2008
RoHS
Directive 2011/65/EU (RoHS)EN IEC 63000:2018
Conformity
Degree of protectionFront side: Non-Ex: IP66 with included front foil, With Ex-certification: IP66 with included front foil
Back side: IP20
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-20 ... 65 °C (-4 ... 149 °F)
Relative humiditymax. relative humidity 93% at 40°C (non-condensing) according to EN60068-2-78
Mechanical specifications
MaterialPEEK housing, anodized aluminum backside
Mass300 g
Dimensions126 mm x 81 mm x 25 mm
Cut out dimensions82 mm x 57 mm
Cable length1.8 m / 0.6 m

Classifications

SystemClasscode
ECLASS 13.027280401
ECLASS 12.027280401
ECLASS 11.027280401
ECLASS 10.0.127280401
ECLASS 9.027280401
ECLASS 8.027280401
ECLASS 5.127280401
ETIM 9.0EC002998
ETIM 8.0EC002998
ETIM 7.0EC002998
ETIM 6.0EC002998
ETIM 5.0EC002998
UNSPSC 12.143211710
Product category / 产品类的

Details: RFID20-*

Product Documentation: RFID20-*

选择语言:
Safety and Security Documentation语言文件类型文件大小
Instruction manual / BetriebsanleitungCHSPDF344 KB
Manuals
ManualENGPDF3737 KB

Approvals: RFID20-*

选择语言:
Declaration of Conformity证书号码语言文件类型文件大小
EU Declaration of Conformity (External) / EU-Konformitätserklärung (extern)DOC-7734ALLPDF86 KB
EU Declaration of Conformity (External) / EU-Konformitätserklärung (extern)DOC-7496ALLPDF86 KB

Software: RFID20-*

选择语言:
Device Description Files/DriversRelease Info文件类型文件大小
Driver Package RFID Reader RFID20-* / Gerätetreiber18-35081ZIP---

配套产品: RFID20-*

Accessories
Direct Monitor - System with Enclosure, Fully modular design which enables easy migration of individual components, Large application flexibility due to identical basic components that can be configured as required, Global certificationspa
Direct Monitor - System with Enclosure, Designed for use in the extended temperature range of -20 °C ... 50 °C with rugged aluminum housing, Suitable for outdoor use with various sunshield options, Fully modular design allowing easy migration of individual components, High application flexibility due to identical basic components that can be can be configured as requiredpa
Personal Computer - System with Enclosure, Fully modular design which enables easy migration of individual components, Large application flexibility due to identical basic components that can be configured as required, 7th generation Intel Celeron, Global certificationspa
Personal Computer - System with Enclosure, Designed for use in the extended temperature range of -20 °C ... 50 °C with rugged aluminum housing, Suitable for outdoor use with various sunshield options, Fully modular design allowing easy migration of individual components, High application flexibility due to identical basic components that can be can be configured as required, 7th generation Intel Celeron and i5 embedded processor generationpa
Remote Monitor - System with enclosure, Fully modular design which enables easy migration of individual components, Large application flexibility due to identical basic components that can be configured as required, Thin Client solution (with VisuNet RM Shell firmware), Global certificationspa
Remote Monitor - System with enclosure, Designed for use in the extended temperature range of -20 °C ... 50 °C with rugged aluminum housing, Thin Client solution (with VisuNet RM Shell firmware), Suitable for outdoor use with various sunshield options, Fully modular design allowing easy migration of individual components, High application flexibility due to identical basic components that can be can be configured as requiredpa