Assistance gamme Détecteurs industriels
Tél.: +33 1 60 92 13 13
Fax : +33 1 60 92 13 25
Support en ligne pour la protection contre le risque d’explosion
Tél.: +33 1 60 92 13 14
Fax:  +33 1 60 92 13 25

Non disponible à la vente

Non disponible à la vente
Non disponible à la vente

Type Z & Ex pzc purge and pressurization system 7500-01-AA-STD-UNV-PNO

7500-01-AA-STD-UNV-PNO
  • Global third-party approvals for Class I, II, Div. 2 and Zone 2/22
  • Must be used in conjunction with an EPV-7500-* vent
  • Low cost, compact design, easy to use
  • Universal power: AC or DC
  • Touch screen display with LEDs for easy visual indication
  • Easy setup with pre-set purge programs for your application
  • Automatic pressure compensation with digital manifold
  • Rugged, corrosion-resistant housing

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Téléchargez ici la fiche technique complète en PDF:


Caractéristiques techniques  7500-01-AA-STD-UNV-PNO

Description produit
7500 series type Z & Ex pzc purge and pressurization control unit
General specifications
Equipment architecturemax. enclosure size 450 ft3 (12.7 m3)
Operating modefully automatic (FA)
Series7500
Hazardous environmentgas or dust
Supply
Rated voltage20 ... 30 V DC at 0.1 A
90 ... 250 V AC , 50 ... 60 Hz at 0.04 A without solenoid valve
Supply voltage can be line-to-line or line-to-neutral, single phase
OVC II
Power consumptionmax. 2.7 W / 7.3 VA without valve
Electrical specifications
Connectionscrew terminals -- see manual for specifications on wire size and torque values
Output
Output I
ConnectionK1, terminals, 1 x NO
Output typeenclosure power contacts
Contact loading5 A at 250 V AC , 5 A at 30 V DC, relays must be externally fused inrush current: 50 A
Output II
ConnectionK2, terminals, 1 x NO
Output typealarm and control contacts
Contact loading5 A at 250 V AC , 5 A at 30 V DC, relays must be externally fused inrush current: 50 A
Output III
ConnectionSV1, terminals, L1 powered contact
Output typesolenoid manifold, contact
Contact loading0.5 A at 250 V AC , 0.5 A
Indicators/settings
LED indicationK1: Green - Contact K1 is energized (enclosure contacts)
K2: Amber - Contact K2 is energized (alarm/control contacts)
P/SV: Blue - Safe pressure P1 (minimum enclosure pressure)
P/SV: Amber - Solenoid manifold is energized (purging/pressure compensation)
Pneumatic parameters
Protective gas supplycompressed air or inert gas, 5 µm filter, free from oil
Pressure requirementsupply pressure: 20 ... 120 psig (1.4 ... 8.2 bar)
Safe pressure0.38 in wc (0.95 mbar) minimum for gas
0.80 in wc (2.0 mbar) minimum for dust
pressure sensing: ± 0.125 in wc (0.31 mbar)
Enclosure pressure0 ... 10 in wc (0 ... 24.8 mbar)
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
RoHS
Directive 2011/65/EU (RoHS)EN IEC 63000:2018
Conformity
Electromagnetic compatibilityEN 61326-3-2:2008, EN 61000-6-2:2005
Emitted interferenceFCC CFR 47, part 15, subpart B: 2017 , ICES-003, Issue 6:2016, Class A ITE
Ambient conditions
Ambient temperature-40 ... 50 °C (-40 ... 122 °F) at T6
-40 ... 65 °C (-40 ... 149 °F) at T5
-40 ... 70 °C (-40 ... 158 °F) at T4
Storage temperature-40 ... 80 °C (-40 ... 176 °F)
Relative humidity5 ... 90 %, non-condensing
Altitudemax. 2000 m
Vibration resistance5 ... 100 Hz , 1 g, 12 m/s2, all axes
Impact resistance30 g, 11 ms, all axes
Mechanical specifications
Connection typeelectrical: 2 x 1/2 inch NPTF (open from factory)
1 x M12 opening (plugged from factory)
pneumatic: high-pressure port - 1/8 in NPTF, low-pressure port - 1/8 in NPTF
Degree of protectionType 4X , IP66
MaterialLens: Makrolon® GP-V polycarbonate
Screws: AISI 316 (1.4401), 304, or 18-8 stainless steel
Housing: A380, A356, or 6061-T6 aluminum
Mounting gasket: Bisco® HT-800 medium cellular silicone
Mounting tabs: SAE 304 stainless steel
M12 plug: 6061-T6 aluminum
Mass710 g (1 lb 10 oz)
Dimensions150 x 100 x 50 mm (5.9 x 4 x 2 in)
Data for application in connection with hazardous areas
Certificate
MarkingEx-Hexagon II 3 G Ex ec mc nC [pzc Gc] IIC T6...T4 Gc
Ex-Hexagon II 3 D Ex mc tc [pzc Dc] IIIC T60 °C ... T80 °C Dc
Directive conformity
Directive 2014/34/EUIEC/EN 60079-0 , IEC/EN 60079-2 , IEC/EN 60079-7 , IEC/EN 60079-15 ,
IEC/EN 60079-18 , IEC/EN 60079-31
Supplements: EN 61010-1:2010
International approvals
UL approval
cULusClass I, Division 2, Groups A, B, C, D T6 ... T4
Class II, Division 2, Groups F, G T6 ... T4
IECEx approvalEx ec mc nC [pzc Gc] IIC T6...T4 Gc
Ex mc tc [pzc Dc] IIIC T60 °C ... T80 °C Dc
General information
Supplementary informationType Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027180508
ECLASS 12.027180508
ECLASS 11.027180508
ECLASS 10.0.127180508
ECLASS 9.027180508
ECLASS 8.027180508
ECLASS 5.140050501
ETIM 9.0EC000243
ETIM 8.0EC000243
ETIM 7.0EC000243
ETIM 6.0EC000243
ETIM 5.0EC000243
UNSPSC 12.139121301

Details: 7500-01-AA-STD-UNV-PNO

Informative Literature: 7500-01-AA-STD-UNV-PNO

Language Selection:
LiteratureLangueType de fichierTaille
Product Information - Pepperl+Fuchs Bebco EPS® 7500 Series Type Z/Ex pzc Purge and Pressurization SystemENGPDF682 KB

Product Documentation: 7500-01-AA-STD-UNV-PNO

Language Selection:
Technical White PapersLangueType de fichierTaille
Technical white paper: Choosing a Purge and Pressurization SystemENGPDF3352 KB
Technical white paper: Prevent Dust Explosions with PressurizationENGPDF2459 KB
Product information
Basic Explosion Protection Compendium - Type of Protection "Purge and Pressurization"ENGPDF3860 KB
Brief Instructions
Programming Quick GuideENGPDF228 KB
Safety and Security Documentation
Manuel d'instructionsFRAPDF164 KB

Design / Simulation: 7500-01-AA-STD-UNV-PNO

Language Selection:
CADLangueType de fichierTaille
CAD 2-D / CAD 2-DALLZIP1622 KB
CAD 3-D / CAD 3-DALLSTP10197 KB
CAD Portal / CAD PortalALLLINK---

Approvals: 7500-01-AA-STD-UNV-PNO

Language Selection:
CertificatesIdentificationLangueType de fichierTaille
ATEX CertificateDEMKO 18 ATEX 2025XALLPDF551 KB
IECEx Certificate of ConformityIECEx UL 18.0022XALLLINK---
Korea KOSHA18-AV4BO-0462XALLPDF504 KB
UL Hazardous LocationE184741 (RFPW, RFPW7, RFPZ, RFPZ7)ALLPDF349 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-B0C4CALLPDF171 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-B0F8ALLPDF167 KB

Produits associés : 7500-01-AA-STD-UNV-PNO

Accessories
pa
You must purchase a 7500 series control unit with this vent.pa
You must purchase a 7500 series control unit with this vent.pa
You must purchase a 7500 series control unit with this vent.pa
You must purchase a 7500 series control unit with this vent.pa
You must purchase a 7500 series control unit with this vent.pa
You must purchase a 7500 series control unit with this vent.pa
pa
Manifold valve used in UL certified installationpa
Manifold valve used in UL certified installationpa
Manifold valve used in UL certified installationpa
Manifold valve used in UL certified installationpa
Manifold valve used in ATEX and IECEx certificated installationpa

Découvrez la façon la plus intelligente de garantir la protection des zones à risques d'explosion et de configurer votre système individuel de purge et pressurisation !

Ce système de purge et pressurisation porte la protection des zones à risque d'explosion à un niveau supérieur d'innovation et de fiabilité. Conçu pour les environnements classés Class I ou II/Div. 2 et Zone 2/22, il fournit des fonctionnalités uniques dans un très petit boîtier…