Guided Level Radar LTC57

LTC57
  • Premium device for level measurement in bulk solids
  • Measuring range up to 45 m (148 foot)
  • Process connection 1-1/2 inch thread or flange
  • Temperature range up to 150 °C (302 °F)
  • Pressure range up to 16 bar (232 psi)
  • Up to SIL 3 acc. to IEC/EN 61508

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Scarica il Datasheet completo in formato PDF:


Estratto del Datasheet: Dati tecnici del  LTC57

General specifications
Measuring methodThe device is a measuring system that functions according to the time-of-flight method. The distance from the reference point (process connection of the measuring device) to the product surface is measured.
Construction typedevice with rod probe
device with rope probe
SeriesLTC57
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Supply
Rated voltage11.5 ... 35 V DC, 2-wire
10.4 ... 48 V DC, 4-wire
90 ... 253 V AC, 50/60 Hz
Input
Measured variabledistance between reference point and product surface
Measuring rangerod probe: 4 m (13 ft)
rope probe: 45 m (148 ft)
Output
Output signal4 ... 20 mA
2 x 4 ... 20 mA
Communication4 ... 20 mA HART (standard)
PROFIBUS PA (option)
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006
Low voltage
Directive 2014/35/EUEN 61010-1:2010
Conformity
Degree of protectionIEC 60529:2001
Measurement accuracy
Accuracydigital:
- measuring range up to 15 m (49 feet): ±2 mm (0.08 inch)
- measuring range > 15 m (49 feet): ±10 mm (0.39 inch)
analog: 0.02 %
sum of non-linearity, non-repeatability and hysteresis included in the maximum measured error
Operating conditions
Process conditions
Process temperature-30 ... 150 °C (-22 ... 302 °F)
Process pressure (static pressure)-1 ... 16 bar (-14.5 ... 232.1 psi)
Dielectric constantrod probe: DC ≥ 1.6
rope probe: DC ≥ 1.6
Ambient conditions
Ambient temperature-40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Degree of protectionIP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep)
IP66, NEMA 4X
Connectiongland M20
thread M20, G1/2, NPT1/2
device plug M12, 7/8 in
Materialmaterials in contact with process :
rod probe: 1.4404/316L
rope probe: 1.4401/316 (optional PA coated)
process connections: 1.4301/304, 1.4401/316, 1.4404/316L
process membran, seal: Viton, EPDM
Process connectionthreads: G1-1/2, NPT1-1/2
flanges: DIN EN from DN40, ANSI from 1-1/2", JIS from DN40
Data for application in connection with hazardous areas
EU-type examination certificatesee instruction manuals (SI)
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-1:2007 , EN 60079-11:2012 , EN 60079-15:2010 , EN 60079-26:2007 , EN 60079-31:2009
International approvals
IECEx approvalsee instruction manuals (SI)
Certificates and approvals
Overspill protectionsee approval (ZE)
Telecommunicationsradio license FCC
General information
Supplementary documentationtechnical information (TI)
manuals, brief instructions (BA, KA)
instruction manuals (SI)
approval (ZE)
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Accessories
Designationsee technical information (TI)

Classifications

SystemClasscode
ECLASS 13.027200513
ECLASS 12.027200513
ECLASS 11.027200513
ECLASS 10.0.127200513
ECLASS 9.027200513
ECLASS 8.027200513
ECLASS 5.127200513
ETIM 9.0EC002995
ETIM 8.0EC002995
ETIM 7.0EC002995
ETIM 6.0EC002995
ETIM 5.0EC001447
UNSPSC 12.141111950

Details: LTC57

Informative Literature: LTC57

Language Selection:
LiteratureLinguaFile tipoDimensioni
Application Report - Reliable Level Measurement with Explosion ProtectionENGPDF214 KB

Product Documentation: LTC57

Language Selection:
Product informationLinguaFile tipoDimensioni
TI01004O, Technical information LTC57ENGPDF2837 KB
Brief Instructions
KA1061O, brief instructions LTC57 HARTENGPDF1972 KB
KA1073O, brief instructions LTC57 PROFIBUS PAENGPDF1681 KB
Safety and Security Documentation
SI00496O, Instruction manual LTC50, LTC51, LTC57ENGPDF1164 KB
SD00326O, Functional Safety Manual LTC5XENGPDF3235 KB
SI00498O, Instruction manual LTC50, LTC51, LTC57ENGPDF1249 KB
SI00501O, Instruction manual LTC57ENGPDF1257 KB
SI00502O, Instruction manual LTC50, LTC51, LTC57ENGPDF1281 KB
SI00503O, Instruction manual LTC50, LTC51, LTC57ENGPDF1230 KB
SI00516O, Instruction manual LTC50, LTC51, LTC57ENGPDF1299 KB
SI00518O, Instruction manual LTC50, LTC51, LTC57ENGPDF1550 KB
SI00521O, Instruction manual LTC57ENGPDF1037 KB
SI00522O, Instruction manual LTC50, LTC51, LTC57ENGPDF1180 KB
SI00523O, Instruction manual LTC50, LTC51, LTC57ENGPDF1168 KB
SI00529O, Instruction manual LTC50, LTC51, LTC57ENGPDF881 KB
SI00530O, Instruction manual LTC50, LTC51, LTC57ENGPDF1094 KB
SI00531O, Instruction manual LTC50, LTC51, LTC57ENGPDF1093 KB
SI00532O, Instruction manual LTC50, LTC51, LTC57ENGPDF875 KB
SI00570O, Instruction manual LTC50, LTC51, LTC57ENGPDF623 KB
SI00571O, Instruction manual LTC50, LTC51, LTC57ENGPDF842 KB
SI00572O,Instruction manual LTC50, LTC51, LTC57ENGPDF626 KB
SI00573O,Instruction manual LTC50, LTC51, LTC57ENGPDF841 KB
SI01125O, Instruction manual LTC50, LTC51, LTC57ENGPDF1261 KB
SI01126O, Instruction manual LTC50, LTC51, LTC57ENGPDF1258 KB
SI01130O, Instruction manual LTC50, LTC51, LTC57ENGPDF1386 KB
SI01131O, Instruction manual LTC50, LTC51, LTC57ENGPDF1382 KB
SI01132O, Instruction manual LTC50, LTC51, LTC57ENGPDF1253 KB
SI01136O, Instruction manual LTC50, LTC51, LTC57ENGPDF1305 KB
Manuals
BA01004O, Manual LTC57 HARTENGPDF3928 KB
BA01009O, Manual LTC57 PROFIBUS PAENGPDF3624 KB

Design / Simulation: LTC57

Language Selection:
CADLinguaFile tipoDimensioni
CAD 3-D / CAD 3-DALLSTP1837 KB
CAD Portal / CAD PortalALLLINK---

Approvals: LTC57

Language Selection:
CertificatesCertificato NumeroLinguaFile tipoDimensioni
Canada FMFM 16 CA 0206XALLPDF205 KB
Canada, USACoC 70105058 CUSALLPDF99 KB
Europe KEMA Ex ic ATEX Ex ta Ex iaDEKRA 14 ATEX 0117XALLPDF419 KB
Europe Pepperl+Fuchs ATEX Category 3 G Certificate of CompliancePF15CERT3612XALLPDF301 KB
Europe Pepperl+Fuchs ATEX Category 3 G Certificate of CompliancePF15CERT3604XALLPDF197 KB
Europe Pepperl+Fuchs ATEX Category 3 G Certificate of CompliancePF15CERT3605XALLPDF297 KB
KEMA IECEx Certificate of ConformityIECEx DEK 14.0066XALLLINK---
USA FMFM 16 US 0454XALLPDF205 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-0091CALLPDF136 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-1936BALLPDF92 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-1937BALLPDF91 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-1941BALLPDF126 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-1939BALLPDF130 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-1940BALLPDF124 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-1938CALLPDF135 KB
Contamination Declaration
Contamination declaration / Kontaminationserklärung   ALLPDF137 KB

Prodotti associati : LTC57

Accessories
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa
Device DTM, For level devices, Frame application, like e. g. PACTware, must be installed separatelypa
Hub sicurezza funzionale di Pepperl+Fuchs

Diverse centinaia di prodotti con valutazione SIL/PL, strumenti gratuiti e brochure in un unico posto: l'hub "Sicurezza funzionale" è il tuo punto di partenza per l'implementazione delle funzioni di sicurezza.