2 axis acceleration sensor, E1-Type approval, Analog output 4 mA ... 20 mA, Fixed evaluation limits , High shock resistance, Teachable zero point, Measuring range -2 g ... +2 g, Increased noise immunity 100 V/mfa
Mounting flange, 18 mm, Retainer for all cylindrical sensors with M18 thread, Simple installation and exact setting, Large sensing range (max. 20 mm)fa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Niet beschikbaar voor verkoop: 1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energized to safe function, Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Up to PL e acc. to EN/ISO 13849, Housing width: 12.5 mm, Number of channels: 1-channel, DTS function (de-energized to safe), Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC loop powered, Type: 1 x logic inputpa
Niet beschikbaar voor verkoop: 1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 26.5 V DC, non-polarized, Fail-safe relay contact output for de-energized and energized to safe function , Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, ETS function (energized to safe), DTS function (de-energized to safe), DPS function (dual pole switching), Safety Integrity Level (SIL): SIL 3pa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Type: 3-wire connection, Type [2]: 4-wire connection, Type [3]: 5-wire connection, Field device: potentiometer, Signal: 1 x 0 ... 10 Vpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niet beschikbaar voor verkoop: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Niet beschikbaar voor verkoop: 1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 4 mA ... 20 mA, Lead resistance compensation adjustment, Accuracy 0.05 %, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Type: 3-wire connection, Type [2]: 4-wire connection, Type [3]: 5-wire connection, Field device: potentiometer, Signal: 1 x 4 ... 20 mApa
Niet beschikbaar voor verkoop: Surge protection for 2 supply lines, Type 3 acc. to EN 61643-11, Nominal voltage 120 V AC, Pre-wired unit, Operating state and fault indication of every protected line, Fault indication output, DIN rail mountable, Device type: type 3 acc. to EN 61643-11:2013 class III acc. to IEC 61643-1:2011, Number of protected supply lines: 2pa
Niet beschikbaar voor verkoop: Protection module for 1 supply line, Type 2 acc. to EN 61643-11, Exchange device for surge protection barrier M-LB-*.275*.D, Easy replacement of protection modules wihtout tools, High discharge capacity, Module can be exchanged under voltage (hot swap), Device type: type 2 acc. to EN 61643-11 class II acc. to IEC 61643-1, Number of protected supply lines: 1pa
TheG20controlmodulesformotorizedrollershaveanapplication-optimized, slimdesignthatallowsdirectinstallation in themountingrail of therollerconveyorlineLearnmoreaboutthemodulesandtheavailableprotocols ... enablesthepre-assembly of individualconveyorsegments, whichcanbeputintooperationdirectlyonsite. EasyHandling In additiontosimpleinstallation, theG20seriesimpresseswithauser-friendlyoperatingconceptandaclearlylaidoutstatus ...
TheUSi-industryultrasonicsensorsystem is theidealsensorsolutionfordustyenvironments, outdoorareasandconfinedinstallationspaces ... route. Atthesametime, it is importanttoensurethatthesensorsignals of theindividualAMRsdonotinterferewitheachother. Asakeycomponent of ananti-collisionassistant, theUSi-industrysensorsystemwithitslarge3-Ddetectionfield ...
Pepperl+Fuchs' WILSENvalveandWILSENnodearewirelessM+OsensorsolutionsformyriadIoTusecases ... work—afterappropriatesafetymeasureshavebeentaken. TheWILSEN.nodesolutioncanbeusedtoensurethatthe door of atransformerhouse is alwaysproperlyclosedwhennomaintenancework is beingcarriedout. Forthispurpose, aninductivesensor ...
Ontdekzeerrobuuste en betrouwbaresensoren, systemen en oplossingen die bestand zijn tegen de ongunstigeomstandigheden in de mijnbouw ... automationtechnologyhelpstomakeminingprocessessaferandmoreefficient. Forexample, collisionscanbeavoided, dangeroussituationscanberecognizedatanearlystage, andthewaste of resourcescanbeprevented. Pepperl+Fuchs' extensiveportfolio ...
Het WCS werd ontworpen voor toepassingen met extremeomgevingsomstandigheden of zeerlangescanafstanden ... bescherming tot IP69. Eenvoudigeset-up De outdoorversie van het WCSbeschikt over een doorzichtigebehuizing die een goedezichtbaarheid over status-LED’s en displaylevert. Informatiebetreffend de actuelepositie of foutmeldingen kunnen zo makkelijk en snel ...
Interfacetechnologie van Pepperl+Fuchsbiedt een breedscala aan onderdelen en oplossingen voor toepassingen in explosiegevaarlijkeomgevingen in de procesindustrie ... : Intrinsiekveiligebarrier van het K-systeem, hogebedrijfsmarge met capaciteit tot 45mA (voor veiligheidsgerelateerdetoepassingen: SIL3ESD- en DCS-systemen die LFTnodig hebben om SIL-niveau te bereiken voor DO-kaarten/kanalen) Rioolwaterzuiveringsinstallaties ...
Van batterijcel naar batterijmodule tot afgewerktebatterij: Pepperl+Fuchsbiedtkrachtigesensortechnologieën voor een geautomatiseerdebatterijproductie ... dat twee vellentegelijk worden ingevoerd, wordt een ultrasoneM18-dubbelvelsensorgebruikt. Dankzij zijn robuustmeetprincipedetecteert deze sensor op betrouwbarewijzezeerdunne of reflecterendefolies. Toezicht op geleiderol in de productie van batterijcellen ...
Automatischedeuren, liften, roltrappen, slagbomen of openbaarvervoer: de sensoren van Pepperl+Fuchs zijn breedinzetbaarbinnen de toegangsautomatisering ... . Standaarddeurbeveiliging De actieveinfraroodscannerDoorScan® monitort de zones voor en achter deurvleugels om personen en voorwerpen te beschermen en te voorkomen dat deze met de deur in contactkomen. Met zijn SIL2/PLd-certificatievoldoet deze sensor ...
Pepperl+Fuchsbiedt u een volledigeIO-Link-systeemoplossing die een ruimassortiment van IO-Link-sensoren en bijbehorendeinfrastructuuromvat ... , bijvoorbeeld in magazijnactiviteiten en materialhandling... Meer info In alle situatieswaarinconventionelesignaallampen hun limietenbereiken, biedt de nieuwesignaallampextrafuncties, dankzij de geïntegreerdeIO-Link-interfaceV1.1 (COM3/KlasseA ...
1-10/937Artikelen per pagina:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.