General specifications | ||
---|---|---|
Effective detection range | 0 ... 10 m | |
Reflector distance | 0.05 ... 10 m | |
Threshold detection range | 12 m | |
Reference target | H85-2 reflector | |
Light source | LED | |
Light type | modulated visible red light | |
LED risk group labelling | exempt group | |
Polarization filter | yes | |
Diameter of the light spot | approx. 300 mm at a distance of 10 m | |
Opening angle | 2 ° | |
Ambient light limit | EN 60947-5-2 : 60000 Lux | |
Functional safety related parameters | ||
MTTFd | 642 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green: power on | |
Function indicator | Yellow LED: Permanently lit - light path clear Permanently off - object detected Flashing (4 Hz) - insufficient operating reserve Flashing (8 Hz) - fault detected, the outputs maintain the status |
|
Control elements | Light-on/dark-on changeover switch | |
Control elements | sensitivity adjustment | |
Electrical specifications | ||
Operating voltage | 24 ... 240 V AC/DC | |
No-load supply current | < 30 mA at 24 V Operating voltage | |
Protection class | II | |
Rated insulation voltage | 250 V | |
Rated impulse withstand voltage | 2500 V | |
Power consumption | ≤ 3.5 VA | |
Fuse | Safety fuse ≤ 2 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
|
Output | ||
Switching type | The switching type of the sensor is adjustable. The default setting is: Q - BK: normally-open / dark-on /Q - GY: normally-closed / light-on C - WH: Common |
|
Signal output | Relay, 1 alternator | |
Switching voltage | max. 240 V AC/DC | |
Switching current | max. 2.5 A , see section characteristic curve | |
Switching power | DC: max. 95 W AC: max. 600 VA | |
Usage category | DC-12 , DC-13 , AC-12 u. AC-140 | |
Switching frequency | 25 Hz | |
Response time | ≤ 20 ms | |
Conformity | ||
Product standard | EN 60947-5-2 , EN 60947-1 | |
Approvals and certificates | ||
UL approval | E87056 , cULus Listed | |
Ambient conditions | ||
Ambient temperature | -30 ... 60 °C (-22 ... 140 °F) , cable, fixed installation -20 ... 60 °C (-4 ... 140 °F) , movable cable not appropriate for conveyor chains |
|
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Pollution degree | 3 | |
Mechanical specifications | ||
Degree of protection | IP67 | |
Connection | 2 m fixed cable | |
Material | ||
Housing | PC (Polycarbonate) | |
Optical face | PMMA | |
Mass | approx. 120 g | |
Dimensions | ||
Height | 62 mm | |
Width | 20 mm | |
Depth | 42 mm | |
Cable length | 2 m |
System | Classcode |
---|---|
ECLASS 13.0 | 27270902 |
ECLASS 12.0 | 27270902 |
ECLASS 11.0 | 27270902 |
ECLASS 10.0.1 | 27270902 |
ECLASS 9.0 | 27270902 |
ECLASS 8.0 | 27270902 |
ECLASS 5.1 | 27270902 |
ETIM 9.0 | EC002717 |
ETIM 8.0 | EC002717 |
ETIM 7.0 | EC002717 |
ETIM 6.0 | EC002717 |
ETIM 5.0 | EC002717 |
UNSPSC 12.1 | 39121528 |
Literature | Lingua | File tipo | Dimensioni |
---|---|---|---|
Application Report - Reliable Detecting Foil Tears in Battery Cell Manufacturing | ENG | 163 KB |
CAD | Lingua | File tipo | Dimensioni |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 1014 KB |
Certificates | Certificato Numero | Lingua | File tipo | Dimensioni |
---|---|---|---|---|
/cert/cert7189.pdf | E87056, Vol. 1, Sec. 62 | ALL | 531 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) | TDOC-7384_ITA | ITA | 219 KB | |
UK Declaration of Conformity (P+F) | TDOC-7385_ENG | ENG | 196 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|