Retroreflective sensor GLV18-6-4594

GLV18-6-4594
  • Short design in M18 plastic housing
  • 4 LEDs indicator for 360° visibility
  • Optimal price/power ratio

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Scarica il Datasheet completo in formato PDF:


Estratto del Datasheet: Dati tecnici del  GLV18-6-4594

Descrizione prodotto
Retroreflective sensor
General specifications
Effective detection range0 ... 4 m
Reflector distance0.05 ... 4 m
Threshold detection range5.5 m
Reference targetreflector C110-2
Light sourceIRED
Light typeIRED , Modulated light , 880 nm
Polarization filterno
Diameter of the light spotapprox. 200 mm at 5.5 m
Opening angleapprox. 2 °
Optical facefrontal
Ambient light limit30000 Lux
Accessories providedMounting aids
Indicators/operating means
Operation indicatorLED green, statically lit Power on
Function indicatorLED yellow: lights up when receiving the light beam ; flashes when falling short of the operating reserve; OFF when light beam is interrupted
Electrical specifications
Operating voltage10 ... 30 V DC
No-load supply current< 20 mA
Output
Switching typelight-on
Signal output1 PNP, short-circuit protected, open collector
Switching voltagemax. 30 V DC
Switching currentmax. 100 mA
Voltage drop≤ 1.5 V DC
Switching frequency500 Hz
Response time≤ 1 ms
Conformity
Product standardEN 60947-5-2
Approvals and certificates
Protection classII, Rated insulation voltage ≤ 50 V AC with pollution degree 1-2 according to IEC 60664-1
UL approvalcULus Listed, Class 2 Power Source
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Degree of protectionIP67
Connectionfixed cable 7000 mm
Material
HousingPC
Optical facePMMA
Massapprox. 270 g
Dimensions
Length39.8 mm
Diameter18 mm
Thread sizeM18

Classifications

SystemClasscode
ECLASS 13.027270902
ECLASS 12.027270902
ECLASS 11.027270902
ECLASS 10.0.127270902
ECLASS 9.027270902
ECLASS 8.027270902
ECLASS 5.127270902
ETIM 9.0EC002717
ETIM 8.0EC002717
ETIM 7.0EC002717
ETIM 6.0EC002717
ETIM 5.0EC002717
UNSPSC 12.139121528

Details: GLV18-6-4594

Product Documentation: GLV18-6-4594

Language Selection:
Brief InstructionsLinguaFile tipoDimensioni
Instruction leaflet / BeipackzettelALLPDF455 KB

Design / Simulation: GLV18-6-4594

Language Selection:
CADLinguaFile tipoDimensioni
CAD 3-D / CAD 3-DALLSTP621 KB
CAD Portal / CAD PortalALLLINK---

Approvals: GLV18-6-4594

Language Selection:
CertificatesCertificato NumeroLinguaFile tipoDimensioni
Canada USA UL Ordinary LocationUL-US-L87056-11-41301991-3 / UL-CA-L87056-31-41301991-3ALLPDF1806 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-0066EALLPDF310 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-5333ALLPDF306 KB

Prodotti associati : GLV18-6-4594

Accessories

Mounting flange, 18 mm, Retainer for all cylindrical sensors with M18 thread, Simple installation and exact setting, Large sensing range (max. 20 mm)fa

Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mmfa
Mounting Bracket with swivel nutfa
Plastic mounting adapter, 18 mmfa
Sensori fotoelettrici serie R10x e R20x

Per la prima volta, una vasta gamma di sensori fotoelettrici e tecnologie innovative si incontrano in un design di custodie standardizzato. Gli utenti beneficiano di un concetto operativo uniforme in tutta la gamma. Scopri le serie R100, R101, R103, R200 e R201...

Sensore fotoelettrico ML100

Che si tratti di vetro, wafer solari o schede a circuito stampato: I sensori fotoelettrici della serie ML100 sono realizzati su misura per soddisfare i requisiti di varie attività di rilevamento complesse. Maggiori informazioni sulla gamma...