Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Scarica il Datasheet completo in formato PDF:
Descrizione prodotto |
---|
Bebco EPS 5500 series Type Z & Ex pzc purge and pressurization control unit |
General specifications | ||
---|---|---|
Operating mode | fully automatic (FA) | |
Series | 5500 | |
System | Type Z Purge ; Ex pzc Purge | |
Number of volume exchanges | 4 ... 19 | |
Hazardous environment | gas or dust | |
Supply | ||
Rated voltage | 100 ... 240 V AC, 0.05 A, 50 ... 60 Hz 20 ... 30 V DC, 0.2 A |
|
Power consumption | 100 ... 240 V AC - 2.3 VA (without digital valve) 20 ... 30 V DC - 2.5 W (without digital valve) |
|
Electrical specifications | ||
Fuse rating | F2: AC: max. 2 A DC: max. 3.15 A F1: AC: max. 0.08 A DC: max. 0.5 A |
|
Input | ||
Input I | Temperature, up to 2 RTDs per unit | |
Connection | Pt100, 2-wire-connection | |
Input type | temperature input Input accuracy: 2.5% of the measurement value + PT100 error |
|
Input II | 1 Bypass | |
Connection | passive contact (switch) | |
Input type | mechanical contact | |
Output | ||
Output I | ||
Connection | K1, terminals: K1/N0, K1/N0 | |
Output type | enclosure power, (1) SPST | |
Inrush current | 6 A | |
Contact loading | 6 A at 250 V AC , 30 V DC resistive load, 6 A at 30 V DC | |
Output II | ||
Connection | K2, terminals: K2 (NO, C, NC) | |
Output type | alarm, (1) SPDT | |
Inrush current | 3 A | |
Contact loading | 3 A at 250 V AC , 30 V DC resistive load, 3 A at 30 V DC | |
Output III | ||
Connection | digital valve, terminals SV | |
Output type | (1) SPST, powered contacts from supply 5.0 A at 250 VAC or 30 VDC |
|
Inrush current | 5 A | |
Indicators/settings | ||
LED indication | Membrane Pad K1: Green - Contact K1 is energized K2: Amber - Contact K2 is energized SV/encl press.: Blue for safe pressure, Amber for valve on Bypass: Amber when bypass is active PT100 error: Red when fault in PT100 sensor |
|
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Safe pressure | - gas 0.7 mbar (0.3 in w.c.) - dust 1.6 mbar (0.65 in w.c.) |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
RoHS | ||
Directive 2011/65/EU (RoHS) | EN IEC 63000:2018 | |
Conformity | ||
Degree of protection | EN 60529 | |
Shock resistance | EN 60068-2 | |
Ambient conditions | ||
Ambient temperature | -20 ... 40 °C (-4 ... 104 °F) at T6 -20 ... 60 °C (-4 ... 140 °F) at T4 |
|
Relative humidity | 5 ... 95 %, non-condensing | |
Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s2, all axes | |
Impact resistance | 30 g, 11 ms, all axes | |
Mechanical specifications | ||
Connection type | High pressure port: 1/8" NPTF Low pressure port: 1/8" NPTF |
|
Cable gland | Cable size M12 diameter 3 - 6.5 mm M20 diameter 10 - 12 mm RTD/Bypass: (3) M12x1.5 K1, K2, SV: 'P_C' (3) M20x1.5 |
|
Degree of protection | Type 4X, IP66 | |
Material | Housing: 316 stainless steel Cable Gland: 316 stainless steel or Nickel Plated Brass Pressure Ports: 316 stainless steel Membrane Pad: Autotex F200XE O-ring: EPDM |
|
Mass | approx. 2.7 kg (6 lb) | |
Dimensions | 165 x 124 x 90 mm (6.5 x 4.9 x 3.5 in) | |
Height | 203 mm | |
Width | 165 mm | |
Depth | 105 mm | |
Data for application in connection with hazardous areas | ||
Certificate | DEMKO 14 ATEX 1282X | |
Marking | II 3 (3) G Ex ic ec nC [ic Gc] [pzc Gc] IIC T4 Gc (-20 °C ≤ Ta ≤ 60 °C) II 3 (3) G Ex ic ec nC [ic Gc] [pzc Gc] IIC T6 Gc (-20 °C ≤ Ta ≤ 40 °C) II 3 (3) D Ex ic tc [ic IIIC Dc] [pzc Dc] IIIB T80 °C Dc (-20 °C ≤ Ta ≤ 60 °C) (external version) II 3 (3) D Ex ic tc [ic IIIC Dc] [pzc Dc] IIIB T60 °C Dc (-20 °C ≤ Ta ≤ 40 °C) (external version) II 3 (3) D Ex ic tc [ic Dc] [pzc Dc] IIIC T80 °C Dc (-20 °C ≤ Ta ≤ 60 °C) (internal version) II 3 (3) D Ex ic tc [ic Dc] [pzc Dc] IIIC T60 °C Dc (-20 °C ≤ Ta ≤ 40 °C) (internal version) |
|
Directive conformity | ||
Directive 2014/34/EU | EN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-15:2019 , EN 60079-2:2014 , EN 60079-7:2015+A1:2018 , EN 60079-31:2014 |
|
International approvals | ||
UL approval | ||
cULus | UL File E184741 Class I, Division 2, Groups A, B, C, D T4 (-20 °C ≤ Ta ≤ 60 °C) Class II, Division 2, Groups F, G, T4 (-20 °C ≤ Ta ≤ 60 °C) Class I, Division 2, Groups A, B, C, D T6 (-20 °C ≤ Ta ≤ 40 °C) Class II, Division 2, Groups F, G T6 (-20 °C ≤ Ta ≤ 40 °C) |
|
IECEx approval | IECEx UL 14.0019X Ex ic ec nC [ic Gc] [pzc Gc] IIC T4 Gc (-20 °C ≤ Ta ≤ 60 °C) Ex ic ec nC [ic Gc] [pzc Gc] IIC T6 Gc (-20 °C ≤ Ta ≤ 40 °C) Ex ic tc [ic IIIC Dc] [pzc Dc] IIIB T80 °C Dc (-20 °C ≤ Ta ≤ 60 °C) (external version) Ex ic tc [ic IIIC Dc] [pzc Dc] IIIB T60 °C Dc (-20 °C ≤ Ta ≤ 40 °C) (external version) Ex ic tc [ic Dc] [pzc Dc] IIIC T80 °C Dc (-20 °C ≤ Ta ≤ 60 °C) (internal version) Ex ic tc [ic Dc] [pzc Dc] IIIC T60 °C Dc (-20 °C ≤ Ta ≤ 40 °C) (internal version) |
|
General information | ||
Supplementary information | Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27180508 |
ECLASS 12.0 | 27180508 |
ECLASS 11.0 | 27180508 |
ECLASS 10.0.1 | 27180508 |
ECLASS 9.0 | 27180508 |
ECLASS 8.0 | 27180508 |
ECLASS 5.1 | 40050501 |
ETIM 9.0 | EC000243 |
ETIM 8.0 | EC000243 |
ETIM 7.0 | EC000243 |
ETIM 6.0 | EC000243 |
ETIM 5.0 | EC000243 |
UNSPSC 12.1 | 39121301 |
Product information | Lingua | File tipo | Dimensioni |
---|---|---|---|
Basic Explosion Protection Compendium - Type of Protection "Purge and Pressurization" | ENG | 3860 KB | |
Brief Instructions | |||
Purge & Pressurization Smart App - Users Guide / Purge & Pressurization Smart App - Users Guide | ALL | 1771 KB | |
5500 Series Purge and Pressurization Quick Guide | ENG | 1140 KB | |
Safety and Security Documentation | |||
Manuale di istruzioni | ITA | 163 KB | |
Manuals | |||
User Manual for the 5500 Series Purge and Pressurization System | ENG | 2706 KB |
CAD | Lingua | File tipo | Dimensioni |
---|---|---|---|
DWG and STP files for the Purge 5500, External Mount Version "EXT1" / CAD 2-D | ALL | ZIP | 2832 KB |
DWG and STP files for the Purge 5500, Internal Mount Version "PM01" and "PM02" / CAD 2-D | ALL | ZIP | 2800 KB |
Certificates | Certificato Numero | Lingua | File tipo | Dimensioni |
---|---|---|---|---|
ATEX Certificate | DEMKO 14 ATEX 1282X | ALL | 129 KB | |
China SITIIAS CCC Ex Certificate | 2020322304002488 (Katy, TX USA) | ALL | 1580 KB | |
IECEx Certificate of Conformity | IECEx UL 14.0019X | ALL | LINK | --- |
India PESO (India) CCOE | A/P/HQ/KA/104/5761 (P471351) | ALL | 563 KB | |
Korea KOSHA | 16-AV4BO-0139X | ALL | 530 KB | |
UL Hazardous Location | E184741 (RFPW, RFPW7) | ALL | LINK | 431 KB |
Control Drawings | ||||
5500 Pz, Type Z Purge System control drawing / Control drawing UL | ALL | 130 KB | ||
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-B020F | ALL | 162 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-B0G0A | ALL | 159 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|