Servizio assistenza Sensori Industriali
Telefono: +39 039 69599 1
Fax.: +39 039 69599 30
Servizio assistenza Protezione contro le esplosioni
Telefono ++39 039 62921
Fax ++39 039 6292 390

IO-Link Motor Roller Module ICA-8IO-4M4-G20-IO-P14

ICA-8IO-4M4-G20-IO-P14
  • Configuration and control via IO-Link
  • Connections for 24 V or 48 V DC roller motors
  • Inputs for 2- and 3-wire sensors
  • Electronic PNP outputs
  • Function indicator for motors, inputs and outputs
  • Mounting directly in the support profile

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Scarica il Datasheet completo in formato PDF:


Estratto del Datasheet: Dati tecnici del  ICA-8IO-4M4-G20-IO-P14

Descrizione prodotto
G20 MDR module with IO-Link for 8 digital inputs/outputs and 4 connections for MDRs (24 V / 48 V)
General specifications
UL File NumberE223772 "For use in NFPA 79 Applications only"
MTBF90 a
Compatible roller motorsInterroll EC310, Interroll EC5000 24V/48V AI (20W / 35W / 50W), Rulmeca BL3, Itoh Denki PM500XK, Itoh Denki PM500XC , PULSEROLLER Senergy-IDC
Indicators/operating means
LED yellow/redIO1 ... IO8: IN, OUT, IO-Link status
M1 ... M4: motor status
Electrical specifications
Auxiliary voltage18 ... 56 V DC PELV Max. 10 A
Current limitation of the supply max. 30 A
For UL: Z-type miniature circuit breaker in accordance with UL 1077, max. 20 A, required
Operating voltage18 ... 30 V DC, PELV
Current limitation of the supply max. 4 A
No-load supply current≤ 25 mA
Operating currentmax. 2.5 A
Interface
Interface typeIO-Link
IO-Link revision1.1
Device profileIdentification and Diagnosis - I&D
Firmware update
Process data8 byte inputs (STD/EXT)
6 byte outputs (STD)
18 byte outputs (EXT)
Vendor ID1 (0x0001)
Device ID984068 (0x0F0404) (STD) - default
984067 (0x0F0403) (EXT)
Data transfer rateCOM3 (230.4 kbits/s)
Min. cycle time1.2 ms (STD)
2 ms (EXT)
SIO mode supportno
Compatible master port typeClass A
Input
Number/Type8 Inputs for 3-wire sensors (PNP), DC (IO1 ... IO8)
Supplyfrom IO-Link
Current loading capacity200 mA per connection IO1/2 ... IO7/8 , overload and short-circuit protected
Input current≤ 5 mA (limited internally)
Switching pointType 3 according to IEC 61131-2
Output 1
Number/Type8 electronic outputs, PNP (IO1 … IO8), overload proof and short-circuit proof
Supplyfrom IO-Link
Current200 mA per output
Voltage≥ (Ue - 1.5 V)
Output 2
Number/Type4 outputs for DC roller motors (MOT1 ... MOT4)
Supplyvia UPWR
Current loading capacity3.5 A (continuous), 5 A (< 2 s), max. 7.5 A (< 0.3 s) per motor
Total current (continuous)
max. 10 A per device (TB ≤ 50 °C)
max. 6 A per device (TB ≤ 60 °C)
Overload protectionFuse 4 A, I2t = 122.5 A2s per motor
Signal levelSpeed: US = 0.3 … 10 V in no-load operation
Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ
Direction of rotation: Digital output PNP
UD low = high resistance
UD high ≥ 12 V
Ri = 5.6 kΩ, RLOAD ≥ 15 kΩ
Fault levelMotor fault: Digital input NPN
0 (no error) ≥ 125 µA
1 (error) ≤ 25 µA
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
EN 55011:2016
Standard conformity
Degree of protectionEN 60529:2000
Fieldbus standardEN 61131-9:2013
InputEN 61131-2:2007
Communication interfaceIEC 61131-9 / IO-Link V1.1.3
Emitted interferenceEN 61000-6-4:2007
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006
Approvals and certificates
UL approval
O1 ... O8 (Output 1): Load specification DC General Use / DC Pilot Duty
Degree of protection not tested by UL; tested by Pepperl+Fuchs SE
Ambient conditions
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 70 °C (-13 ... 158 °F)
Relative humidity85 % non-condensing
Climatic conditionsFor indoor use only
Altitude≤ 5000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks
Vibration resistance0.35 mm / 5 g 5 ... 500 Hz
Pollution degree2
Mechanical specifications
Degree of protectionIP54 according to EN 60529
Connection24 V/48 V power (PWR): Piercing technology, black or gray flat cable
IO-Link: M12 round plug connector in accordance with EN 61076-2-101, LM type (4-pin, connector contacts, screw-locking, A-coded)
Female connector: LF type or similar
Inputs/outputs (IO), motors (MOT): M8 round plug connector in accordance with EN 61076-2-104
IO: LF type (4-pin, bushing contacts, screw-locking, A-coded)
Female connector: LM type or similar
MOT: NF type (5-pin, bushing contacts, snap-locking, B-coded)
Female connector: NM type or similar
Mass390 g
Dimensions
Height27.5 mm
Width131.5 mm
Length54 mm
Mounting2 clips with ∅ 8 mm drill hole
The module must be secured to a solid, continuous surface using the two lugs
Cable length1 m (IO-Link)
1.5 m (IO1/2, IO7/8), 0.8 m (IO3/4, IO5/6)
1.0 m (MOT1, MOT4); 0.4 m (MOT2, MOT3)
max. 10 m
NoteThe flat cable routing is designed for 100 actuation cycles

Classifications

SystemClasscode
ECLASS 13.027242602
ECLASS 12.027242602
ECLASS 11.027242602
ECLASS 10.0.127242602
ECLASS 9.027242602
ECLASS 8.027242602
ECLASS 5.127242602
ETIM 9.0EC001597
ETIM 8.0EC001597
ETIM 7.0EC001597
ETIM 6.0EC001597
ETIM 5.0EC001597
UNSPSC 12.132151705

Details: ICA-8IO-4M4-G20-IO-P14

Product Documentation: ICA-8IO-4M4-G20-IO-P14

Language Selection:
Brief InstructionsLinguaFile tipoDimensioni
Instruction leaflet / BeipackzettelALLPDF206 KB
Manuals
ManualENGPDF766 KB
Parameter Information
IODD for ICA-8IO-4M4-G20-IO-P14 (EXT)ENGPDF512 KB
IODD for ICA-8IO-4M4-G20-IO-P14 (STD)ENGPDF510 KB

Design / Simulation: ICA-8IO-4M4-G20-IO-P14

Language Selection:
CADLinguaFile tipoDimensioni
CAD 3-D / CAD 3-DALLSTP3418 KB

Approvals: ICA-8IO-4M4-G20-IO-P14

Language Selection:
CertificatesCertificato NumeroLinguaFile tipoDimensioni
IO-Link Manufacturer DeclarationCERT-7376ALLPDF173 KB
Declaration of Conformity
EU Declaration of Conformity (P+F)TDOC-7569_ITAITAPDF194 KB
UK Declaration of Conformity (P+F)TDOC-7571_ENGENGPDF171 KB

Software: ICA-8IO-4M4-G20-IO-P14

Language Selection:
Device Description Files/Driversinformazioni sulla liberatoriaFile tipoDimensioni
IODD for ICA-8IO-4M4-G20-IO-P14 (EXT) / IODD für ICA-8IO-4M4-G20-IO-P14 (EXT)V1.00.000 / 2024-04-10ZIP223 KB
IODD for ICA-8IO-4M4-G20-IO-P14 (STD) / IODD für ICA-8IO-4M4-G20-IO-P14 (STD)V1.00.000 / 2024-04-10ZIP222 KB
Software Tools
IO-Link Offline Parameterization Tool / IO-Link Offline-ParametriertoolV1.00.006 / 2022-07-10ZIP96138 KB

Prodotti associati : ICA-8IO-4M4-G20-IO-P14

Accessories
Mounting aidfa
Voltage limiter G10fa
Cordset M8 socket snap-lock straight to M8 plug snap-lock straight B-coded, 5-pin, PUR cable black, UL-approved, drag chain suitable, torsion resistantfa
Cordset M8 socket snap-lock straight to M8 plug snap-lock straight B-coded, 5-pin, PUR cable black, UL-approved, drag chain suitable, torsion resistantfa
Starter kit IIoT

Collegate al cloud i sensori utilizzati in fabbrica e iniziate la trasformazione digitale con i nuovi starter kit IIoT.