Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Scarica il Datasheet completo in formato PDF:
Descrizione prodotto |
---|
Distance sensor |
General specifications | ||
---|---|---|
Measuring range | 100 ... 300 mm | |
Reference target | standard white, 100 mm x 100 mm | |
Light source | laser diode | |
Light type | modulated visible red light | |
Laser nominal ratings | ||
Note | LASER LIGHT , DO NOT STARE INTO BEAM | |
Laser class | 1 | |
Wave length | 680 nm | |
Beam divergence | > 5 mrad, d63 < 2,8 mm in the range of 350 mm ... 800 mm | |
Pulse length | 5.5 µs | |
Repetition rate | approx. 2.4 kHz | |
max. pulse energy | < 40 nJ | |
Angle deviation | max. +/- 1.5 ° | |
Diameter of the light spot | approx. 3 mm at a distance of 300 mm | |
Opening angle | approx. 0.3 ° | |
Ambient light limit | EN 60947-5-2 : 45000 Lux | |
Resolution | 0.1 mm | |
Functional safety related parameters | ||
MTTFd | 470 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
|
Function indicator | LED yellow: constantly on - switch output active constantly off - switch output inactive |
|
Control elements | Teach-In key | |
Control elements | 5-step rotary switch for operating modes selection | |
Electrical specifications | ||
Operating voltage | 18 ... 30 V DC | |
Ripple | max. 10 % | |
No-load supply current | < 18 mA at 24 V supply voltage | |
Protection class | III | |
Interface | ||
Interface type | IO-Link ( via C/Q = pin 4 ) | |
IO-Link revision | 1.1 | |
Device profile | Identification and diagnosis Smart Sensor type 0/type 3.3 |
|
Device ID | 0x11190C (1120524) | |
Transfer rate | COM2 (38.4 kBit/s) | |
Min. cycle time | 3 ms | |
Process data width | Process data input 4 byte Process data output 2 bits |
|
SIO mode support | yes | |
Compatible master port type | A | |
Output | ||
Switching type | The default setting is: C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link U—Pin2: analog output 0 ... 10 V |
|
Signal output | 1 push-pull output , 1 analog output , short-circuit-proof, reverse polarity protection, surge-proof | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA , resistive load | |
Usage category | DC-12 and DC-13 | |
Voltage drop | ≤ 1.5 V DC | |
Response time | 2 ms | |
Analog output | ||
Output type | 1 voltage output: 0 ... 10 V | |
Load resistor | > 1 kΩ voltage output ; ≤ 470 Ω current output | |
Recovery time | 2 ms | |
Conformity | ||
Communication interface | IEC 61131-9 | |
Product standard | EN 60947-5-2 | |
Laser safety | EN 60825-1:2014 | |
Measurement accuracy | ||
Temperature drift | 0.05 %/K | |
Warm up time | 5 min | |
Repeat accuracy | < 0.5 % | |
Linearity error | 0.5 % | |
Approvals and certificates | ||
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
FDA approval | IEC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 | |
Ambient conditions | ||
Ambient temperature | 10 ... 50 °C (50 ... 122 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Degree of protection | IP67 / IP69 / IP69K | |
Connection | fixed cable 300 mm with M8 x 1 male connector; 4-pin | |
Material | ||
Housing | PC (Polycarbonate) | |
Optical face | PMMA | |
Mass | approx. 41 g | |
Dimensions | ||
Height | 50.6 mm | |
Width | 15 mm | |
Depth | 41.7 mm | |
Cable length | 0.3 m |
System | Classcode |
---|---|
ECLASS 13.0 | 27270916 |
ECLASS 12.0 | 27270916 |
ECLASS 11.0 | 27270801 |
ECLASS 10.0.1 | 27270801 |
ECLASS 9.0 | 27270801 |
ECLASS 8.0 | 27270801 |
ECLASS 5.1 | 27270801 |
ETIM 9.0 | EC001825 |
ETIM 8.0 | EC001825 |
ETIM 7.0 | EC001825 |
ETIM 6.0 | EC001825 |
ETIM 5.0 | EC001825 |
UNSPSC 12.1 | 41111613 |
I sensori ottici della serie sono i primi dispositivi nel loro genere in grado di offrire una soluzione end-to-end in design standard di medie dimensioni, dalla fotocellula a sbarramento al sensore di misurazione della distanza. Come risultato del design, i sensori possono eseguire praticamente tutte le normali attività di automazione.
Tutta la serie di sensori permette di comunicare via IO-Link.
I sensori laser DuraBeam sono resistenti e possono essere utilizzati allo stesso modo di un sensore standard.
La tecnologia MPT (Multi Pixel Technology) garantisce la flessibilità dei sensori standard, così che possano adattarsi all'ambiente applicativo.
Literature | Lingua | File tipo | Dimensioni |
---|---|---|---|
Product information - R10x and R20x Series Standard Housings - All Sensing Modes | ENG | 2583 KB | |
Application Report - Compact Design and Precise Distance Measurement up to 60 m | ENG | 332 KB | |
Application Report - Reliable Detecting Foil Tears in Battery Cell Manufacturing | ENG | 163 KB |
Product information | Lingua | File tipo | Dimensioni |
---|---|---|---|
Installation and user instructions for offline parameterization of IO-Link sensors | ENG | 1788 KB | |
Brief Instructions | |||
Instruction leaflet / Beipackzettel | ALL | 251 KB |
CAD | Lingua | File tipo | Dimensioni |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 1079 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
CAE | |||
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZ | ALL | EDZ | 73 KB |
Certificates | Certificato Numero | Lingua | File tipo | Dimensioni |
---|---|---|---|---|
Canada USA UL Ordinary Location | UL-US-L87056-11-41301991-3 / UL-CA-L87056-31-41301991-3 | ALL | 1806 KB | |
IO-Link Manufacturer Declaration | CERT-4527A | ALL | 318 KB | |
Declaration of Conformity | ||||
Declaration of Conformity for simple apparatus / Konformitätserklärung für einfache Betriebsmittel | DOC-3935A | ALL | 308 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-5594 | ALL | 231 KB |
Device Description Files/Drivers | informazioni sulla liberatoria | File tipo | Dimensioni |
---|---|---|---|
IODD for OMT-AO-R200 series / IODD für OMT-AO-R200 Serie | V1.00.002 / 2019-03-30 | ZIP | 926 KB |
DTM for OMT/OQT R20x series / DTM für OMT/OQT R20x Serie | V1.0.3.0 / 2021-01-18 | ZIP | 9622 KB |
Software Tools | |||
IO-Link Offline Parameterization Tool / IO-Link Offline-Parametriertool | V1.00.006 / 2022-07-10 | ZIP | 96138 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|